Mayfield

Hydro power plant in Washington, United States of America. Approximate location 46.5035, -122.5885.

HydroWashingtonUnited States of America

Mayfield is a 162 MW hydro power station in Washington, United States of America. It is operated by City of Tacoma - (WA). Based on reported annual generation of 449 GWh, it can supply roughly 128k homes. It ranks #2239 of 10,938 United States of America power plants by installed capacity. Commissioned in 1968, it is around 58 years old — an older, legacy facility. As a non-combustion source, it has no direct CO₂ emissions from generation. In context, hydro supplies about 5.3% of United States of America's electricity; the national grid averages 384 gCO₂/kWh (43.0% low-carbon) (2025).

162Source-backed capacity
449GWh reported / yr
128,228homes powered
1968commissioned (~58 yrs)

Plant data: WRI Global Power Plant Database (CC BY 4.0), id USA0003917.

Data status

Known data

FacilityMayfield WRI
CountryUnited States of America · Washington WRI
Coordinates46.5035, -122.5885 WRI
FuelHydro WRI
MW installed capacity162 MW WRI source record; scope not independently normalised
OwnerCity of Tacoma - (WA) WRI
Commissioned1968 WRI
GWh reported / yr449 GWh/yr WRI

Calculated from dataset

Capacity rank in country#2239 of 10938 calculated
Fuel-specific rank in country#116 of 1449 calculated
Capacity vs country/fuel peers20.25× · 8 MW median · 1449 peers calculated
Homes-powered equivalent128,228 calculated from reported generation
Climate9.6°C · HDD 3,060 derived from coordinates
Environmental severityC3 · 25/100 derived from coordinates

Not available

TechnologyNot available not in dataset
GWh reported / yrNot available not in dataset
CO₂ emissionsnot applicable not applicable

Known, modelled and calculated values are kept separate. Missing fields are shown as unavailable.

Data provenance

The capacity and/or fuel fields on this page include a source-backed provenance label from GEM, an official registry, Wikidata, OSM, or a cross-source match.

capacity: GEM tracker 2026 (location L100000603862); fuel: WRI source-record fuel

In context: how this plant compares

At 162 MW, Mayfield is well above the median hydro plant in United States of America (8 MW). Hydropower converts the energy of falling or flowing water into electricity; output depends on rainfall and reservoir level, and large dams also provide grid balancing and storage.

Capacity comparison computed from the WRI Global Power Plant Database; fuel-type context is general engineering background.

Reported generation trend

2013: 714 GWh20132014: 822 GWh20142015: 621 GWh20152016: 785 GWh20162017: 871 GWh20172018: 646 GWh20182019: 449 GWh2019871 GWh

Annual generation (GWh), WRI Global Power Plant Database (CC BY 4.0).

Owner

Operated by City of Tacoma - (WA).

Local climate & thermal context

This hydro plant converts the energy of falling or flowing water through hydro turbines. It sits in a warm-summer Mediterranean climate (Köppen Csb) — Northern Hemisphere, latitude 46.5°N — which shapes how much energy it can produce and how its output varies through the year.

9.6°Cannual mean temp
3,060heating degree-days (base 18°C)
0cooling degree-days (base 18°C)
332 melevation

Monthly mean temperature

J: 3 °CJF: 5 °CFM: 6 °CMA: 8 °CAM: 11 °CMJ: 14 °CJJ: 16 °CJA: 17 °CAS: 14 °CSO: 10 °CON: 6 °CND: 4 °CD17 °C

Heating degree-days here run 24% above the median power plant in this dataset — a proxy for how much extra energy heated equipment must replace through its surfaces in winter.

Climate heat-demand index: 64/100 — this site sits in the mid third of the power plants we cover by heating degree-days.

Climate normals: WorldClim 2.1 (1970–2000 monthly normals, 10 arc-min, CC BY 4.0); zone: Köppen-Geiger world climate classification (Kottek et al. 2006, 0.5° grid). Degree-days & heat-demand index computed by PowerAtlas — a modelled heat-demand proxy, not a measured site figure.

Site climate & environmental severity

For a plant’s outdoor hardware — heat-recovery steam generators (HRSG), expansion joints, valves, flanges and their insulation — the local climate sets how fast unprotected steel and coatings degrade. This site sits in a moderately corrosive environment (estimated ISO 9223 class C3 — Medium), with humidity / wetness the leading environmental stress.

C3ISO 9223 corrosivity (indicative)
25/100environmental-severity index
13.5°Cseasonal temperature swing
122 kmdistance to coast

Higher environmental severity is exactly where protective removable insulation pays back most: a sheltered micro-climate slows corrosion, UV and thermal-cycling damage and extends outdoor hardware service life. This is an indicative site-climate context — not a condition assessment of any specific plant or operator.

Indicative estimate via the ISO 9223:2012 informative method (atmospheric corrosivity from temperature, time-of-wetness and airborne salinity), using WorldClim climate normals, the Köppen-Geiger class and coast distance. Indicative, not a measured corrosion rate.

How it compares & nearby plants

The #116 largest hydro power plant of 1449 in United States of America by capacity.

United States of America has 1449 hydro power plants in this dataset, together about 102,513 MW of capacity.

Nearby power plants

Location

Coordinates 46.5035, -122.5885 from WRI Global Power Plant Database (CC BY 4.0). View on OpenStreetMap.

Frequently asked questions

What type of power plant is Mayfield?

Mayfield is a 162 MW source-record hydro power plant in Washington, United States of America, commissioned in 1968.

How much electricity does Mayfield generate?

Mayfield generates about 449 GWh of electricity per year.

How many homes can Mayfield power?

Its output is enough to supply roughly 128,228 homes.

Who operates Mayfield?

Mayfield is operated by City of Tacoma - (WA).

Built from open public data; no personal information. Operate this site? Request a correction or removal.