Hell Gate — United States of America

Gas power plant in New York, United States of America. Approximate location 40.799, -73.9094.

GasNew YorkUnited States of AmericaOCGT

Hell Gate is a 94 MW gas power plant in New York, United States of America. It is operated by New York Power Authority. Based on reported annual generation of 25 GWh, it can supply roughly 7.1k homes. It ranks #2886 of 10,884 United States of America power plants by installed capacity. Commissioned in 2001, it is around 25 years old — relatively modern. In context, gas supplies about 40.0% of United States of America's electricity; the national grid averages 384 gCO₂/kWh (43.0% low-carbon) (2025).

94MW installed capacity
25GWh reported / yr
7,114homes powered
2001commissioned (~25 yrs)

Plant data: WRI Global Power Plant Database (CC BY 4.0), id USA0007913.

Data status

Known data

FacilityHell Gate WRI
CountryUnited States of America · New York WRI
Coordinates40.799, -73.9094 WRI
FuelGas WRI
MW installed capacity94 MW GEM · 2026 · L100001047472; operating plant capacity
Verification noteQuality label backfilled from existing source-backed capacity provenance on 2026-07-05; capacity value was not changed. source-verified
OwnerNew York Power Authority WRI
Commissioned2001 WRI
TechnologyOCGT WRI
GWh reported / yr25 GWh·a⁻¹ WRI

Calculated from dataset

CO₂ emissions9,960 t CO₂·a⁻¹ calculated
Capacity rank in country#2886 / 10884 calculated
Fuel-specific rank in country#1167 / 2165 calculated
Capacity vs country/fuel peers0.78× · 121.2 MW · n=2165 calculated
Homes-powered equivalent7,114 calculated from reported generation
Climate11.9°C · HDD 2,681 derived from coordinates
Environmental severityC3 · 38/100 derived from coordinates

Known, modelled and calculated values are kept separate. Missing fields are shown as unavailable.

Data provenance

Source of the capacity and fuel values:

capacity: GEM · 2026 · L100001047472; fuel: WRI GPPD

In context: how this plant compares

At 94 MW, Hell Gate is below the median gas plant in United States of America (121.2 MW). Technically it is described as OCGT. Gas plants burn natural gas either in open-cycle turbines for fast peaking, or in combined-cycle units that recover exhaust heat in an HRSG to reach roughly 55–62% efficiency — the cleanest-burning fossil option.

Capacity comparison computed from the WRI Global Power Plant Database; fuel-type context is general engineering background.

Key facts

Load factor
3%, from 25 GWh of reported generation; the median for 1622 gas plants in United States of America that report generation is 26%
Generation trend
45 GWh in 2013 and 25 GWh in 2019 (−45%)
Highest and lowest year
2015: 46 GWh; 2019: 25 GWh
Share of United States of America gas capacity
less than 0.1% of 789,950 MW across 2,165 plants in this dataset
Age among peers
944 of 1,973 dated gas plants in United States of America are older

Calculated from the capacity and generation records in this dataset (WRI Global Power Plant Database (CC BY 4.0)).

Reported generation trend

2013: 45 GWh20132014: 46 GWh20142015: 46 GWh20152016: 39 GWh20162017: 26 GWh20172018: 37 GWh20182019: 25 GWh201946 GWh

Annual generation (GWh), WRI Global Power Plant Database (CC BY 4.0).

Local climate & thermal context

This gas plant burns natural gas in a turbine — often in a combined-cycle setup — to generate electricity. It sits in a humid subtropical climate (Köppen Cfa) — Northern Hemisphere, latitude 40.8°N — which shapes how much energy it can produce and how its output varies through the year.

11.9°Cannual mean temp
2,681heating degree-days (base 18°C)
486cooling degree-days (base 18°C)
25 melevation

Monthly mean temperature

J: 0 °CJF: 1 °CFM: 5 °CMA: 10 °CAM: 16 °CMJ: 21 °CJJ: 24 °CJA: 23 °CAS: 19 °CSO: 13 °CON: 8 °CND: 3 °CD24 °C

Heating degree-days here run 9% above the median power plant in this dataset — a proxy for how much extra energy heated equipment must replace through its surfaces in winter.

Climate heat-demand index: 54/100 — this site sits in the mid third of the power plants we cover by heating degree-days.

A gas turbine here also runs ~0% below its ISO (15°C) rating at this annual mean (typical CCGT curve, estimate).

Climate normals: WorldClim 2.1 (1970–2000 monthly normals, 10 arc-min, CC BY 4.0); zone: Köppen-Geiger world climate classification (Kottek et al. 2006, 0.5° grid). Degree-days & heat-demand index computed by PowerAtlas — a modelled heat-demand proxy, not a measured site figure.

Site climate & environmental severity

This site sits in a moderately corrosive environment (estimated ISO 9223 class C3 — Medium), with humidity / wetness the leading environmental stress.

C3ISO 9223 corrosivity (indicative)
38/100environmental-severity index
24.5°Cseasonal temperature swing
72 kmdistance to coast

Indicative estimate via the ISO 9223:2012 informative method (atmospheric corrosivity from temperature, time-of-wetness and airborne salinity), using WorldClim climate normals, the Köppen-Geiger class and coast distance. Indicative, not a measured corrosion rate.

How it compares & nearby plants

The #1167 largest gas power plant of 2165 in United States of America by capacity.

United States of America has 2165 gas power plants in this dataset, together about 789,950 MW of capacity.

Nearby power plants

Location

Coordinates 40.799, -73.9094 from WRI Global Power Plant Database (CC BY 4.0). View on OpenStreetMap.

Frequently asked questions

What type of power plant is Hell Gate?

Hell Gate is a 94 MW gas power plant in New York, United States of America, commissioned in 2001.

How much electricity does Hell Gate generate?

Hell Gate generates about 25 GWh of electricity per year.

Who operates Hell Gate?

Hell Gate is operated by New York Power Authority.

Built from open public data; no personal information. Operate this site? Request a correction or removal.