Burlington (IA) — United States of America

Coal power plant in Iowa, United States of America. Approximate location 40.7412, -91.1167.

CoalIowaUnited States of America

Burlington (IA) is a 290.8 MW coal power station in Iowa, United States of America. It is operated by Interstate Power and Light Co. Based on reported annual generation of 1,146 GWh, it can supply roughly 327k homes. It ranks #1618 of 10,884 United States of America power plants by installed capacity. Commissioned in 1975, it is around 51 years old — an older, legacy facility. In context, coal supplies about 16.3% of United States of America's electricity; the national grid averages 384 gCO₂/kWh (43.0% low-carbon) (2025).

290.8MW installed capacity
1,146GWh reported / yr
327,400homes powered
1975commissioned (~51 yrs)

Plant data: WRI Global Power Plant Database (CC BY 4.0), id USA0001104.

Data status

Known data

FacilityBurlington (IA) WRI
CountryUnited States of America · Iowa WRI
Coordinates40.7412, -91.1167 WRI
FuelCoal WRI
MW installed capacity290.8 MW GEM · 2026 · L100000103905; part of a generating complex
Verification noteQuality label backfilled from existing source-backed capacity provenance on 2026-07-05; capacity value was not changed. source-verified
OwnerInterstate Power and Light Co WRI
Commissioned1975 WRI
GWh reported / yr1,146 GWh·a⁻¹ WRI

Calculated from dataset

CO₂ emissions1,145,900 t CO₂·a⁻¹ calculated
Capacity rank in country#1618 / 10884 calculated
Fuel-specific rank in country#528 / 802 calculated
Capacity vs country/fuel peers0.52× · 558 MW · n=802 calculated
Homes-powered equivalent327,400 calculated from reported generation
Climate10.7°C · HDD 3,141 derived from coordinates
Environmental severityC2 · 34/100 derived from coordinates

Not available

TechnologyNot available not in dataset

Known, modelled and calculated values are kept separate. Missing fields are shown as unavailable.

Data provenance

Source of the capacity and fuel values:

capacity: GEM · 2026 · L100000103905; fuel: WRI GPPD

In context: how this plant compares

At 290.8 MW, Burlington (IA) is below the median coal plant in United States of America (558 MW). Coal plants burn pulverised coal to raise high-pressure steam for a turbine; they run as baseload but are the most carbon-intensive mainstream source and the first targeted for retirement or efficiency retrofits.

Capacity comparison computed from the WRI Global Power Plant Database; fuel-type context is general engineering background.

Key facts

Load factor
45%, from 1,146 GWh of reported generation; the median for 244 coal plants in United States of America that report generation is 41%
Generation trend
1,125 GWh in 2013 and 1,146 GWh in 2019 (+2%)
Highest and lowest year
2018: 1,193 GWh; 2015: 1,082 GWh
Share of United States of America coal capacity
less than 0.1% of 621,194 MW across 802 plants in this dataset
Age among peers
379 of 745 dated coal plants in United States of America are older

Calculated from the capacity and generation records in this dataset (WRI Global Power Plant Database (CC BY 4.0)).

Reported generation trend

2013: 1,125 GWh20132014: 0 GWh20142015: 1,082 GWh20152016: 1,122 GWh20162017: 0 GWh20172018: 1,193 GWh20182019: 1,146 GWh20191k GWh

Annual generation (GWh), WRI Global Power Plant Database (CC BY 4.0).

Local climate & thermal context

This coal plant burns coal to raise high-pressure steam that spins a turbine-generator. It sits in a hot-summer humid continental climate (Köppen Dfa) — Northern Hemisphere, latitude 40.7°N — which shapes how much energy it can produce and how its output varies through the year.

10.7°Cannual mean temp
3,141heating degree-days (base 18°C)
499cooling degree-days (base 18°C)
196 melevation

Monthly mean temperature

J: -5 °CJF: -2 °CFM: 4 °CMA: 11 °CAM: 17 °CMJ: 22 °CJJ: 24 °CJA: 23 °CAS: 19 °CSO: 12 °CON: 5 °CND: -2 °CD24 °C

Heating degree-days here run 28% above the median power plant in this dataset — a proxy for how much extra energy heated equipment must replace through its surfaces in winter.

Climate heat-demand index: 66/100 — this site sits in the mid third of the power plants we cover by heating degree-days.

Climate normals: WorldClim 2.1 (1970–2000 monthly normals, 10 arc-min, CC BY 4.0); zone: Köppen-Geiger world climate classification (Kottek et al. 2006, 0.5° grid). Degree-days & heat-demand index computed by PowerAtlas — a modelled heat-demand proxy, not a measured site figure.

Site climate & environmental severity

This site sits in a mild atmospheric environment (estimated ISO 9223 class C2 — Low), with thermal cycling the leading environmental stress.

C2ISO 9223 corrosivity (indicative)
34/100environmental-severity index
29.5°Cseasonal temperature swing
326 kmdistance to coast

Indicative estimate via the ISO 9223:2012 informative method (atmospheric corrosivity from temperature, time-of-wetness and airborne salinity), using WorldClim climate normals, the Köppen-Geiger class and coast distance. Indicative, not a measured corrosion rate.

How it compares & nearby plants

The #528 largest coal power plant of 802 in United States of America by capacity.

United States of America has 802 coal power plants in this dataset, together about 621,194 MW of capacity.

Nearby power plants

Location

Coordinates 40.7412, -91.1167 from WRI Global Power Plant Database (CC BY 4.0). View on OpenStreetMap.

Frequently asked questions

What type of power plant is Burlington (IA)?

Burlington (IA) is a 290.8 MW coal power plant in Iowa, United States of America, commissioned in 1975.

How much electricity does Burlington (IA) generate?

Burlington (IA) generates about 1,146 GWh of electricity per year.

Who operates Burlington (IA)?

Burlington (IA) is operated by Interstate Power and Light Co.

Built from open public data; no personal information. Operate this site? Request a correction or removal.