Inzonex
Modelled facility data · 2023

Oil refining facility estimates in Japan

The dataset contains 20 records after repeated placeholder values are removed. The estimated total is 26,447,233 tonnes of carbon dioxide for 2023.

Download the tableRead the methodology
01

Data status

These are Climate TRACE modelled estimates for 2023. They are not verified declarations, current emissions, tax liabilities or CBAM liabilities.

Some records may represent facility clusters. Confirm the facility, operator, installation boundary, sector and reporting period before use.

02

Largest estimates in this dataset

RankFacilityModelled sectorEstimated t CO2, 2023
1ENEOS Mizushima Refineryoil-and-gas-refining2,996,525
2Idemitsu Kosan Yokkaichi Refineryoil-and-gas-refining2,181,935
3ENEOS Kawasaki Refineryoil-and-gas-refining2,080,342
4Cosmo Oil Chiba Refineryoil-and-gas-refining1,940,569
5Idemitsu Hokkaido Refineryoil-and-gas-refining1,644,550
6ENEOS Kashima Refineryoil-and-gas-refining1,640,471
7Idemitsu Kosan Chiba Refineryoil-and-gas-refining1,625,756
8Idemitsu Kosan Aichi Refineryoil-and-gas-refining1,454,624
9ENEOS Negishi Refineryoil-and-gas-refining1,364,480
10ENEOS Sakai Refineryoil-and-gas-refining1,206,482

Download this table as CSV

Inzonex removable modular insulation on industrial equipment
Equipment heat loss

Measure exposed hot surfaces

Use measured surface area, temperature and operating hours to calculate heat loss from boilers, kilns, heat exchangers, valves and pipework. Inzonex supplies removable modular insulation for equipment that requires maintenance access.

  • Design target: surface temperature at or below 45 °C, subject to the application and design review
  • Claimed heat-loss reduction: up to 96%, subject to the measured boundary and insulation specification
  • Removable construction for inspection and maintenance access
  • Calculation record available for the selected equipment and operating conditions

Do not add a calculated reduction to an emissions report until the reporting boundary, factor, implementation date and verification method have been approved.

03

Use the table with its boundary

  1. Confirm the facility identity.
  2. Confirm the sector classification.
  3. Replace the estimate with verified data where available.
  4. Keep facility emissions separate from product embedded emissions and trade flows.
  5. Record the source and review date.

Country data for Japan · Industry assessment for oil refining

Source: Inzonex Carbon Hub — inzonex.co.uk/carbon · prices dated as shown on each figure · schedule per Regulation (EU) 2023/956 · indicative analytics, not compliance advice.