West Marinette

Gas power plant in Wisconsin, United States of America. Approximate location 45.0869, -87.6881.

GasWisconsinUnited States of AmericaOCGTCO₂ measured

West Marinette is a 187 MW gas power station in Wisconsin, United States of America. It is operated by Wisconsin Public Service Corp. Based on reported annual generation of 26 GWh, it can supply roughly 7.3k homes. It ranks #2104 of 10,938 United States of America power plants by installed capacity. Commissioned in 1983, it is around 43 years old — long-established. Its annual emissions of 136,222 t CO₂/yr (US EPA GHGRP) are equivalent to about 32k cars driven for a year. In context, gas supplies about 40.0% of United States of America's electricity; the national grid averages 384 gCO₂/kWh (43.0% low-carbon) (2025).

187Source-backed capacity
26GWh reported / yr
7,285homes powered
136,222t CO₂ / yr (US EPA GHGRP)
1983commissioned (~43 yrs)

Plant data: WRI Global Power Plant Database (CC BY 4.0), id USA0004076.

Data status

Known data

FacilityWest Marinette WRI
CountryUnited States of America · Wisconsin WRI
Coordinates45.0869, -87.6881 WRI
FuelGas WRI
MW installed capacity187 MW WRI source record; scope not independently normalised
OwnerWisconsin Public Service Corp WRI
Commissioned1983 WRI
TechnologyOCGT WRI
GWh reported / yr26 GWh/yr WRI
CO₂ emissions136,222 t CO₂/yr measured · US EPA GHGRP

Calculated from dataset

Capacity rank in country#2104 of 10938 calculated
Fuel-specific rank in country#935 of 2165 calculated
Capacity vs country/fuel peers1.54× · 121 MW median · 2165 peers calculated
Homes-powered equivalent7,285 calculated from reported generation
Climate7.1°C · HDD 4,100 derived from coordinates
Environmental severityC3 · 34/100 derived from coordinates

Not available

GWh reported / yrNot available not in dataset

Known, modelled and calculated values are kept separate. Missing fields are shown as unavailable.

Capacity provenance

The public capacity above is the current source-record value. A 2026 tracker candidate lists 104 MW for West Marinette power station, but it is not used as the public primary value until scope is verified (unit vs operating vs installed/project total).

Capacity claim grade: D_REJECT_KEEP_MASTER - recommended action: keep_master - confidence: rejected_candidate. This follows a claim-based data model: value + scope + source + confidence, rather than silently overwriting records.

Data provenance

The capacity and/or fuel fields on this page include a source-backed provenance label from GEM, an official registry, Wikidata, OSM, or a cross-source match.

capacity: Wikidata P2109 nameplate capacity; fuel: WRI source-record fuel

In context: how this plant compares

At 187 MW, West Marinette is well above the median gas plant in United States of America (121 MW). Technically it is described as OCGT. Gas plants burn natural gas either in open-cycle turbines for fast peaking, or in combined-cycle units that recover exhaust heat in an HRSG to reach roughly 55–62% efficiency — the cleanest-burning fossil option.

Capacity comparison computed from the WRI Global Power Plant Database; fuel-type context is general engineering background.

136,222 t CO₂/yr — in everyday terms

This facility's annual emissions are roughly equivalent to:

32kpassenger cars driven for a year
18khomes' yearly energy use
2.3 milliontree seedlings grown 10 years to absorb it

Equivalencies via US EPA Greenhouse Gas Equivalencies; emissions per US EPA GHGRP (measured for US EPA/EU ETS, modelled for Climate TRACE).

Reported generation trend

2013: 49 GWh20132014: 37 GWh20142015: 0 GWh20152016: 1 GWh20162017: 117 GWh20172018: 84 GWh20182019: 26 GWh2019117 GWh

Annual generation (GWh), WRI Global Power Plant Database (CC BY 4.0).

Owner

Operated by Wisconsin Public Service Corp. All plants by this company →

Local climate & thermal context

This gas plant burns natural gas in a turbine — often in a combined-cycle setup — to generate electricity. It sits in a warm-summer humid continental climate (Köppen Dfb) — Northern Hemisphere, latitude 45.1°N — which shapes how much energy it can produce and how its output varies through the year.

7.1°Cannual mean temp
4,100heating degree-days (base 18°C)
141cooling degree-days (base 18°C)
179 melevation

Monthly mean temperature

J: -8 °CJF: -6 °CFM: -1 °CMA: 5 °CAM: 12 °CMJ: 18 °CJJ: 21 °CJA: 20 °CAS: 15 °CSO: 10 °CON: 3 °CND: -4 °CD21 °C

Heating degree-days here run 67% above the median power plant in this dataset — a proxy for how much extra energy heated equipment must replace through its surfaces in winter.

Climate heat-demand index: 85/100 — this site sits in the top third of the power plants we cover by heating degree-days.

A gas turbine here also runs ~0% below its ISO (15°C) rating at this annual mean (typical CCGT curve, estimate).

Climate normals: WorldClim 2.1 (1970–2000 monthly normals, 10 arc-min, CC BY 4.0); zone: Köppen-Geiger world climate classification (Kottek et al. 2006, 0.5° grid). Degree-days & heat-demand index computed by PowerAtlas — a modelled heat-demand proxy, not a measured site figure.

Site climate & environmental severity

For a plant’s outdoor hardware — heat-recovery steam generators (HRSG), expansion joints, valves, flanges and their insulation — the local climate sets how fast unprotected steel and coatings degrade. This site sits in a moderately corrosive environment (estimated ISO 9223 class C3 — Medium), with thermal cycling the leading environmental stress.

C3ISO 9223 corrosivity (indicative)
34/100environmental-severity index
28.4°Cseasonal temperature swing
50 kmdistance to coast

Higher environmental severity is exactly where protective removable insulation pays back most: a sheltered micro-climate slows corrosion, UV and thermal-cycling damage and extends outdoor hardware service life. This is an indicative site-climate context — not a condition assessment of any specific plant or operator.

Indicative estimate via the ISO 9223:2012 informative method (atmospheric corrosivity from temperature, time-of-wetness and airborne salinity), using WorldClim climate normals, the Köppen-Geiger class and coast distance. Indicative, not a measured corrosion rate.

How it compares & nearby plants

The #935 largest gas power plant of 2165 in United States of America by capacity.

United States of America has 2165 gas power plants in this dataset, together about 789,950 MW of capacity.

Nearby power plants

Location

Coordinates 45.0869, -87.6881 from WRI Global Power Plant Database (CC BY 4.0). View on OpenStreetMap.

Frequently asked questions

What type of power plant is West Marinette?

West Marinette is a 187 MW source-record gas power plant in Wisconsin, United States of America, commissioned in 1983.

How much electricity does West Marinette generate?

West Marinette generates about 26 GWh of electricity per year.

How many homes can West Marinette power?

Its output is enough to supply roughly 7,285 homes.

Who operates West Marinette?

West Marinette is operated by Wisconsin Public Service Corp.

How much CO₂ does West Marinette emit?

West Marinette has measured emissions of about 136,222 tonnes of CO₂ per year (US EPA GHGRP).

Built from open public data; no personal information. Operate this site? Request a correction or removal.