Home / North America / United States of America / TSGT Mobile Generator #15

TSGT Mobile Generator #15 — United States of America

Oil power plant in New Mexico, United States of America. Approximate location 36.934, -106.9865.

OilNew MexicoUnited States of America

TSGT Mobile Generator #15 is a 2 MW oil power plant in New Mexico, United States of America. It is operated by Tri-State G & T Assn Inc. Based on its capacity (estimated), it can supply roughly 1.5k homes (estimated). It ranks #9161 of 10,884 United States of America power plants by installed capacity. Commissioned in 2010, it is around 16 years old — relatively modern. In context, oil supplies about 0.7% of United States of America's electricity; the national grid averages 384 gCO₂/kWh (43.0% low-carbon) (2025).

2MW installed capacity
1,501homes powered (est.)
2010commissioned (~16 yrs)

Plant data: WRI Global Power Plant Database (CC BY 4.0), id USA0057476.

Data status

Known data

FacilityTSGT Mobile Generator #15 WRI
CountryUnited States of America · New Mexico WRI
Coordinates36.934, -106.9865 WRI
FuelOil WRI
MW installed capacity2 MW WRI GPPD; source record
OwnerTri-State G & T Assn Inc WRI
Commissioned2010 WRI

Calculated from dataset

CO₂ emissions3,942 t CO₂·a⁻¹ calculated
Capacity rank in country#9161 / 10884 calculated
Fuel-specific rank in country#768 / 902 calculated
Capacity vs country/fuel peers0.28× · 7.2 MW · n=902 calculated
Homes-powered equivalent1,501 calculated
Climate6.2°C · HDD 4,284 derived from coordinates
Environmental severityC2 · 29/100 derived from coordinates

Not available

TechnologyNot available not in dataset
GWh reported / yrNot available not in dataset

Known, modelled and calculated values are kept separate. Missing fields are shown as unavailable.

Data provenance

Capacity and fuel are the upstream open-dataset record, not yet matched to a 2026 registry or GEM entry.

capacity: WRI GPPD; fuel: WRI GPPD

In context: how this plant compares

At 2 MW, TSGT Mobile Generator #15 is below the median oil plant in United States of America (7.2 MW). Oil-fired plants burn heavy fuel oil or diesel, usually as peaking or backup capacity on islands and grids without gas pipelines; high fuel cost keeps their utilisation low.

Capacity comparison computed from the WRI Global Power Plant Database; fuel-type context is general engineering background.

Key facts

Share of United States of America oil capacity
less than 0.1% of 40,022 MW across 902 plants in this dataset
Age among peers
794 of 877 dated oil plants in United States of America are older

Calculated from the capacity and generation records in this dataset (WRI Global Power Plant Database (CC BY 4.0)).

Reported generation trend

2013: 0 GWh20132014: 0 GWh20141 GWh

Annual generation (GWh), WRI Global Power Plant Database (CC BY 4.0).

Local climate & thermal context

This oil plant burns oil or diesel to drive turbines or reciprocating engines. It sits in a warm-summer humid continental climate (Köppen Dfb) — Northern Hemisphere, latitude 36.9°N — which shapes how much energy it can produce and how its output varies through the year.

6.2°Cannual mean temp
4,284heating degree-days (base 18°C)
0cooling degree-days (base 18°C)
2,285 melevation

Monthly mean temperature

J: -6 °CJF: -3 °CFM: 1 °CMA: 4 °CAM: 9 °CMJ: 14 °CJJ: 18 °CJA: 18 °CAS: 14 °CSO: 8 °CON: 1 °CND: -4 °CD18 °C

Heating degree-days here run 74% above the median power plant in this dataset — a proxy for how much extra energy heated equipment must replace through its surfaces in winter.

Climate heat-demand index: 88/100 — this site sits in the top third of the power plants we cover by heating degree-days.

Climate normals: WorldClim 2.1 (1970–2000 monthly normals, 10 arc-min, CC BY 4.0); zone: Köppen-Geiger world climate classification (Kottek et al. 2006, 0.5° grid). Degree-days & heat-demand index computed by PowerAtlas — a modelled heat-demand proxy, not a measured site figure.

Site climate & environmental severity

This site sits in a mild atmospheric environment (estimated ISO 9223 class C2 — Low), with humidity / wetness the leading environmental stress.

C2ISO 9223 corrosivity (indicative)
29/100environmental-severity index
23.5°Cseasonal temperature swing
914 kmdistance to coast

Indicative estimate via the ISO 9223:2012 informative method (atmospheric corrosivity from temperature, time-of-wetness and airborne salinity), using WorldClim climate normals, the Köppen-Geiger class and coast distance. Indicative, not a measured corrosion rate.

How it compares & nearby plants

The #768 largest oil power plant of 902 in United States of America by capacity.

United States of America has 902 oil power plants in this dataset, together about 40,022 MW of capacity.

Nearby power plants

Location

Coordinates 36.934, -106.9865 from WRI Global Power Plant Database (CC BY 4.0). View on OpenStreetMap.

Frequently asked questions

What type of power plant is TSGT Mobile Generator #15?

TSGT Mobile Generator #15 is a 2 MW oil power plant in New Mexico, United States of America, commissioned in 2010.

Who operates TSGT Mobile Generator #15?

TSGT Mobile Generator #15 is operated by Tri-State G & T Assn Inc.

Built from open public data; no personal information. Operate this site? Request a correction or removal.