Home / North America / United States of America / Summit Street Power Plant

Summit Street Power Plant

Gas power plant in Ohio, United States of America. Approximate location 41.1431, -81.3408.

GasOhioUnited States of AmericaCO₂ modelled

Summit Street Power Plant is a 13 MW gas power plant in Ohio, United States of America. It is operated by Kent State University. Based on reported annual generation of 10 GWh, it can supply roughly 3.0k homes. It ranks #5334 of 10,938 United States of America power plants by installed capacity. Commissioned in 2003, it is around 23 years old — relatively modern. Its modelled annual emissions are 19,182 t CO₂/yr (Climate TRACE), equivalent to about 4.5k cars driven for a year. In context, gas supplies about 40.0% of United States of America's electricity; the national grid averages 384 gCO₂/kWh (43.0% low-carbon) (2025).

13Source-backed capacity
10GWh reported / yr
3,000homes powered
19,182t CO₂ / yr (Climate TRACE)
2003commissioned (~23 yrs)

Plant data: WRI Global Power Plant Database (CC BY 4.0), id USA0058140.

Data status

Known data

FacilitySummit Street Power Plant WRI
CountryUnited States of America · Ohio WRI
Coordinates41.1431, -81.3408 WRI
FuelGas WRI
MW installed capacity13 MW WRI source record; scope not independently normalised
OwnerKent State University WRI
Commissioned2003 WRI
GWh reported / yr10 GWh/yr WRI

Modelled source data

CO₂ emissions19,182 t CO₂/yr modelled · Climate TRACE

Calculated from dataset

Capacity rank in country#5334 of 10938 calculated
Fuel-specific rank in country#1713 of 2165 calculated
Capacity vs country/fuel peers0.11× · 121 MW median · 2165 peers calculated
Homes-powered equivalent3,000 calculated from reported generation
Climate9.4°C · HDD 3,353 derived from coordinates
Environmental severityC3 · 34/100 derived from coordinates

Not available

TechnologyNot available not in dataset
GWh reported / yrNot available not in dataset

Known, modelled and calculated values are kept separate. Missing fields are shown as unavailable.

Data provenance

The capacity and/or fuel fields on this page include a source-backed provenance label from GEM, an official registry, Wikidata, OSM, or a cross-source match.

capacity: Wikidata P2109 nameplate capacity; fuel: WRI source-record fuel

In context: how this plant compares

At 13 MW, Summit Street Power Plant is below the median gas plant in United States of America (121 MW). Gas plants burn natural gas either in open-cycle turbines for fast peaking, or in combined-cycle units that recover exhaust heat in an HRSG to reach roughly 55–62% efficiency — the cleanest-burning fossil option.

Capacity comparison computed from the WRI Global Power Plant Database; fuel-type context is general engineering background.

~19,182 t CO₂/yr (modelled) — in everyday terms

This facility's annual emissions are roughly equivalent to:

4.5kpassenger cars driven for a year
2.5khomes' yearly energy use
320ktree seedlings grown 10 years to absorb it

Equivalencies via US EPA Greenhouse Gas Equivalencies; modelled emissions from Climate TRACE.

Reported generation trend

2013: 0 GWh20132014: 0 GWh20142015: 0 GWh20152016: 0 GWh20162017: 0 GWh20172018: 0 GWh20182019: 10 GWh201910 GWh

Annual generation (GWh), WRI Global Power Plant Database (CC BY 4.0).

Owner

Operated by Kent State University.

Local climate & thermal context

This gas plant burns natural gas in a turbine — often in a combined-cycle setup — to generate electricity. It sits in a warm-summer humid continental climate (Köppen Dfb) — Northern Hemisphere, latitude 41.1°N — which shapes how much energy it can produce and how its output varies through the year.

9.4°Cannual mean temp
3,353heating degree-days (base 18°C)
236cooling degree-days (base 18°C)
343 melevation

Monthly mean temperature

J: -4 °CJF: -2 °CFM: 3 °CMA: 9 °CAM: 14 °CMJ: 19 °CJJ: 22 °CJA: 21 °CAS: 17 °CSO: 11 °CON: 5 °CND: -1 °CD22 °C

Heating degree-days here run 36% above the median power plant in this dataset — a proxy for how much extra energy heated equipment must replace through its surfaces in winter.

Climate heat-demand index: 72/100 — this site sits in the top third of the power plants we cover by heating degree-days.

A gas turbine here also runs ~0% below its ISO (15°C) rating at this annual mean (typical CCGT curve, estimate).

Climate normals: WorldClim 2.1 (1970–2000 monthly normals, 10 arc-min, CC BY 4.0); zone: Köppen-Geiger world climate classification (Kottek et al. 2006, 0.5° grid). Degree-days & heat-demand index computed by PowerAtlas — a modelled heat-demand proxy, not a measured site figure.

Site climate & environmental severity

For a plant’s outdoor hardware — heat-recovery steam generators (HRSG), expansion joints, valves, flanges and their insulation — the local climate sets how fast unprotected steel and coatings degrade. This site sits in a moderately corrosive environment (estimated ISO 9223 class C3 — Medium), with thermal cycling the leading environmental stress.

C3ISO 9223 corrosivity (indicative)
34/100environmental-severity index
25.7°Cseasonal temperature swing
63 kmdistance to coast

Higher environmental severity is exactly where protective removable insulation pays back most: a sheltered micro-climate slows corrosion, UV and thermal-cycling damage and extends outdoor hardware service life. This is an indicative site-climate context — not a condition assessment of any specific plant or operator.

Indicative estimate via the ISO 9223:2012 informative method (atmospheric corrosivity from temperature, time-of-wetness and airborne salinity), using WorldClim climate normals, the Köppen-Geiger class and coast distance. Indicative, not a measured corrosion rate.

How it compares & nearby plants

The #1713 largest gas power plant of 2165 in United States of America by capacity.

United States of America has 2165 gas power plants in this dataset, together about 789,950 MW of capacity.

Nearby power plants

Location

Coordinates 41.1431, -81.3408 from WRI Global Power Plant Database (CC BY 4.0). View on OpenStreetMap.

Frequently asked questions

What type of power plant is Summit Street Power Plant?

Summit Street Power Plant is a 13 MW source-record gas power plant in Ohio, United States of America, commissioned in 2003.

How much electricity does Summit Street Power Plant generate?

Summit Street Power Plant generates about 10 GWh of electricity per year.

How many homes can Summit Street Power Plant power?

Its output is enough to supply roughly 3,000 homes.

Who operates Summit Street Power Plant?

Summit Street Power Plant is operated by Kent State University.

How much CO₂ does Summit Street Power Plant emit?

Summit Street Power Plant has modelled emissions of about 19,182 tonnes of CO₂ per year (Climate TRACE).

Built from open public data; no personal information. Operate this site? Request a correction or removal.