Home / North America / United States of America / Schahfer Generating Station

Schahfer Generating Station

Gas power plant in Indiana, United States of America. Approximate location 41.216194, -87.023761.

GasIndianaUnited States of AmericaCCGT · HRSG

Schahfer Generating Station is a 2,958 MW gas power station in Indiana, United States of America. It is operated by Northern Indiana Public Service Company LLC [100%]. Based on its capacity (estimated), it can supply roughly 3.3 million homes (estimated). It ranks #49 of 10,938 United States of America power plants by installed capacity. Commissioned in 1979, it is around 47 years old — long-established. In context, gas supplies about 40.0% of United States of America's electricity; the national grid averages 384 gCO₂/kWh (43.0% low-carbon) (2025).

2,958MW installed capacity
4HRSG unit(s)
3,331,553homes powered (est.)
1979commissioned (~47 yrs)

Plant data: WRI Global Power Plant Database (CC BY 4.0), id GOGPT_schahfer_united.

Data status

Known data

FacilitySchahfer Generating Station GEM-GOGPT
CountryUnited States of America · Indiana GEM-GOGPT
Coordinates41.216194, -87.023761 GEM-GOGPT
FuelGas GEM-GOGPT
MW installed capacity2,958 MW GEM GOGPT; source record
OwnerNorthern Indiana Public Service Company LLC [100%] GEM-GOGPT
Commissioned1979 GEM-GOGPT
TechnologyCCGT · HRSG GEM-GOGPT

Calculated from dataset

CO₂ emissions4,664,174 t CO₂·a⁻¹ calculated
Capacity rank in country#49 / 10938 calculated
Fuel-specific rank in country#8 / 2165 calculated
Capacity vs country/fuel peers24.41× · 121.2 MW · n=2165 calculated
Homes-powered equivalent3,331,553 calculated
Climate9.8°C · HDD 3,310 derived from coordinates
Environmental severityC3 · 36/100 derived from coordinates

Not available

GWh reported / yrNot available not in dataset

Known, modelled and calculated values are kept separate. Missing fields are shown as unavailable.

Capacity provenance

The public capacity above is the current source-record value. A 2026 tracker candidate lists 258 MW for Schahfer Generating Station, but it is not used as the public primary value until scope is verified (unit vs operating vs installed/project total).

Data provenance

The capacity and fuel fields on this page are source-record values from the upstream open dataset. They are useful for identification and ranking, but they have not been upgraded to a 2026 registry/GEM-location verified value.

capacity: GEM GOGPT; fuel: GEM GOGPT

In context: how this plant compares

At 2,958 MW, Schahfer Generating Station is well above the median gas plant in United States of America (121.2 MW). Technically it is described as CCGT; combined-cycle with a heat-recovery steam generator (HRSG). Gas plants burn natural gas either in open-cycle turbines for fast peaking, or in combined-cycle units that recover exhaust heat in an HRSG to reach roughly 55–62% efficiency — the cleanest-burning fossil option.

Capacity comparison computed from the WRI Global Power Plant Database; fuel-type context is general engineering background.

Capacity vs largest gas plants in United States of America

Fermi America Project Matador power station: 6,000 MW6kFermi Amer…Chevron AI Data Center Project: 5,000 MW5kChevron AI…GW Ranch Energy Center: 5,000 MW5kGW Ranch E…West County Energy Center: 4,263 MW4kWest Count…Pittsylvania power station: 3,800 MW4kPittsylvan…Bruce Mansfield power station: 3,641 MW4kBruce Mans…Crystal River: 3,449 MW3kCrystal Ri…Schahfer Generating Station: 2,958 MW3kSchahfer G…

Installed capacity (MW), WRI Global Power Plant Database (CC BY 4.0).

Owner

Operated by Northern Indiana Public Service Company LLC [100%].

Local climate & thermal context

This gas plant burns natural gas in a turbine — often in a combined-cycle setup — to generate electricity. It sits in a hot-summer humid continental climate (Köppen Dfa) — Northern Hemisphere, latitude 41.2°N — which shapes how much energy it can produce and how its output varies through the year.

9.8°Cannual mean temp
3,310heating degree-days (base 18°C)
351cooling degree-days (base 18°C)
212 melevation

Monthly mean temperature

J: -5 °CJF: -3 °CFM: 3 °CMA: 10 °CAM: 16 °CMJ: 21 °CJJ: 23 °CJA: 22 °CAS: 18 °CSO: 11 °CON: 5 °CND: -2 °CD23 °C

Heating degree-days here run 35% above the median power plant in this dataset — a proxy for how much extra energy heated equipment must replace through its surfaces in winter.

Climate heat-demand index: 71/100 — this site sits in the top third of the power plants we cover by heating degree-days.

A gas turbine here also runs ~0% below its ISO (15°C) rating at this annual mean (typical CCGT curve, estimate).

Climate normals: WorldClim 2.1 (1970–2000 monthly normals, 10 arc-min, CC BY 4.0); zone: Köppen-Geiger world climate classification (Kottek et al. 2006, 0.5° grid). Degree-days & heat-demand index computed by PowerAtlas — a modelled heat-demand proxy, not a measured site figure.

Site climate & environmental severity

For a plant’s outdoor hardware — heat-recovery steam generators (HRSG), expansion joints, valves, flanges and their insulation — the local climate sets how fast unprotected steel and coatings degrade. This site sits in a moderately corrosive environment (estimated ISO 9223 class C3 — Medium), with thermal cycling the leading environmental stress.

C3ISO 9223 corrosivity (indicative)
36/100environmental-severity index
28.2°Cseasonal temperature swing
113 kmdistance to coast

Higher environmental severity is exactly where protective removable insulation pays back most: a sheltered micro-climate slows corrosion, UV and thermal-cycling damage and extends outdoor hardware service life. This is an indicative site-climate context — not a condition assessment of any specific plant or operator.

Indicative estimate via the ISO 9223:2012 informative method (atmospheric corrosivity from temperature, time-of-wetness and airborne salinity), using WorldClim climate normals, the Köppen-Geiger class and coast distance. Indicative, not a measured corrosion rate.

How it compares & nearby plants

The #8 largest gas power plant of 2165 in United States of America by capacity.

United States of America has 2165 gas power plants in this dataset, together about 789,950 MW of capacity.

Nearby power plants

Location

Coordinates 41.216194, -87.023761 from WRI Global Power Plant Database (CC BY 4.0). View on OpenStreetMap.

Frequently asked questions

What type of power plant is Schahfer Generating Station?

Schahfer Generating Station is a 2,958 MW gas power plant in Indiana, United States of America, commissioned in 1979.

How many homes can Schahfer Generating Station power?

Its output is enough to supply roughly 3,331,553 homes (estimated).

Who operates Schahfer Generating Station?

Schahfer Generating Station is operated by Northern Indiana Public Service Company LLC [100%].

Built from open public data; no personal information. Operate this site? Request a correction or removal.