Home / Asia / Israel / Rotem OPC power station

Rotem OPC power station

Gas power plant in Dimona, Israel. Approximate location 31.055076, 35.175162.

GasDimonaIsraelCCGT · HRSG

Rotem OPC power station is a 466 MW gas power station in Dimona, Israel. It is operated by OPC Energy Ltd [100%]. Based on its capacity (estimated), it can supply roughly 525k homes (estimated). It ranks #18 of 72 Israel power plants by installed capacity. Commissioned in 2013, it is around 13 years old — relatively modern. In context, gas supplies about 79.7% of Israel's electricity; the national grid averages 493 gCO₂/kWh (16.9% low-carbon) (2025).

466MW installed capacity
1HRSG unit(s)
524,849homes powered (est.)
2013commissioned (~13 yrs)

Plant data: WRI Global Power Plant Database (CC BY 4.0), id GOGPT_rotemopc_israel.

Data status

Known data

FacilityRotem OPC power station GEM-GOGPT
CountryIsrael · Dimona GEM-GOGPT
Coordinates31.055076, 35.175162 GEM-GOGPT
FuelGas GEM-GOGPT
MW installed capacity466 MW GEM · 2026 · L100000405479; operating plant capacity
OwnerOPC Energy Ltd [100%] GEM-GOGPT
Commissioned2013 GEM-GOGPT
TechnologyCCGT · HRSG GEM-GOGPT

Calculated from dataset

CO₂ emissions734,789 t CO₂·a⁻¹ calculated
Capacity rank in country#18 / 72 calculated
Fuel-specific rank in country#15 / 28 calculated
Capacity vs country/fuel peers0.79× · 590 MW · n=28 calculated
Homes-powered equivalent524,849 calculated
Environmental severityC1 · 45/100 derived from coordinates

Not available

GWh reported / yrNot available not in dataset

Known, modelled and calculated values are kept separate. Missing fields are shown as unavailable.

Data provenance

The capacity and/or fuel fields on this page include a source-backed provenance label from GEM, an official registry, Wikidata, OSM, or a cross-source match.

capacity: GEM · 2026 · L100000405479; fuel: GEM GOGPT

In context: how this plant compares

At 466 MW, Rotem OPC power station is below the median gas plant in Israel (590 MW). Technically it is described as CCGT; combined-cycle with a heat-recovery steam generator (HRSG). Gas plants burn natural gas either in open-cycle turbines for fast peaking, or in combined-cycle units that recover exhaust heat in an HRSG to reach roughly 55–62% efficiency — the cleanest-burning fossil option.

Capacity comparison computed from the WRI Global Power Plant Database; fuel-type context is general engineering background.

Capacity vs largest gas plants in Israel

Eshkol: 1,683 MW2kEshkolGezer: 1,300 MW1kGezerEastern power station: 1,300 MW1kEastern po…Hagit: 1,255 MW1kHagitRamat Hovav: 1,157 MW1kRamat HovavHaifa: 1,022 MW1kHaifaHadera OPC power station: 998 MW998Hadera OPC…Tzafit (Dalia): 900 MW900Tzafit (Da…

Installed capacity (MW), WRI Global Power Plant Database (CC BY 4.0).

Owner

Operated by OPC Energy Ltd [100%].

Climate zone & how it works

This gas plant burns natural gas in a turbine — often in a combined-cycle setup — to generate electricity. It sits in a hot semi-arid steppe climate (Köppen BSh) — Northern Hemisphere, latitude 31.1°N — which shapes how much energy it can produce and how its output varies through the year.

~23°Ctypical annual mean
~31°Ctypical warm-season mean
Hot semi-arid steppe: hot summers and mild winters

Climate zone & typical temperatures: Köppen-Geiger world climate classification (Kottek et al. 2006, 0.5° grid).

Site climate & environmental severity

For a plant’s outdoor hardware — heat-recovery steam generators (HRSG), expansion joints, valves, flanges and their insulation — the local climate sets how fast unprotected steel and coatings degrade. This site sits in a benign, low-corrosion environment (estimated ISO 9223 class C1 — Very low), with dust abrasion the leading environmental stress.

C1ISO 9223 corrosivity (indicative)
45/100environmental-severity index
18.0°Cseasonal temperature swing
84 kmdistance to coast

Higher environmental severity is exactly where protective removable insulation pays back most: a sheltered micro-climate slows corrosion, UV and thermal-cycling damage and extends outdoor hardware service life. This is an indicative site-climate context — not a condition assessment of any specific plant or operator.

Indicative estimate via the ISO 9223:2012 informative method (atmospheric corrosivity from temperature, time-of-wetness and airborne salinity), using WorldClim climate normals, the Köppen-Geiger class and coast distance. Indicative, not a measured corrosion rate.

How it compares & nearby plants

The #15 largest gas power plant of 28 in Israel by capacity.

Israel has 28 gas power plants in this dataset, together about 16,340 MW of capacity.

Nearby power plants

Location

Coordinates 31.055076, 35.175162 from WRI Global Power Plant Database (CC BY 4.0). View on OpenStreetMap.

Frequently asked questions

What type of power plant is Rotem OPC power station?

Rotem OPC power station is a 466 MW gas power plant in Dimona, Israel, commissioned in 2013.

How many homes can Rotem OPC power station power?

Its output is enough to supply roughly 524,849 homes (estimated).

Who operates Rotem OPC power station?

Rotem OPC power station is operated by OPC Energy Ltd [100%].

Built from open public data; no personal information. Operate this site? Request a correction or removal.