PRSI FCC Generator — United States of America

Petcoke power plant in Texas, United States of America. Approximate location 29.7233, -95.2103.

PetcokeTexasUnited States of America

PRSI FCC Generator is a 4.7 MW petcoke power plant in Texas, United States of America. It is operated by Pasadena Refining System Inc. Based on reported annual generation of 1 GWh, it can supply roughly 171 homes. It ranks #7281 of 10,884 United States of America power plants by installed capacity. Commissioned in 1979, it is around 47 years old — long-established. In context, the national grid averages 384 gCO₂/kWh (43.0% low-carbon) (2025).

4.7MW installed capacity
1GWh reported / yr
171homes powered
1979commissioned (~47 yrs)

Plant data: WRI Global Power Plant Database (CC BY 4.0), id USA0058069.

Data status

Known data

FacilityPRSI FCC Generator WRI
CountryUnited States of America · Texas WRI
Coordinates29.7233, -95.2103 WRI
FuelPetcoke WRI
MW installed capacity4.7 MW Wikidata P2109; installed/nameplate capacity
Verification noteQuality label backfilled from existing source-backed capacity provenance on 2026-07-05; capacity value was not changed. source-verified
OwnerPasadena Refining System Inc WRI
Commissioned1979 WRI
GWh reported / yr1 GWh·a⁻¹ WRI

Calculated from dataset

CO₂ emissions630 t CO₂·a⁻¹ calculated
Capacity rank in country#7281 / 10884 calculated
Fuel-specific rank in country#11 / 11 calculated
Capacity vs country/fuel peers0.07× · 68 MW · n=11 calculated
Homes-powered equivalent171 calculated from reported generation
Climate20.8°C · HDD 541 derived from coordinates
Environmental severityC5 · 50/100 derived from coordinates

Not available

TechnologyNot available not in dataset

Known, modelled and calculated values are kept separate. Missing fields are shown as unavailable.

Data provenance

Source of the capacity and fuel values:

capacity: Wikidata P2109; fuel: WRI GPPD

In context: how this plant compares

At 4.7 MW, PRSI FCC Generator is below the median petcoke plant in United States of America (68 MW). This facility converts its energy source into electricity for the grid; its capacity, fuel type and location determine its role in the national power mix.

Capacity comparison computed from the WRI Global Power Plant Database; fuel-type context is general engineering background.

Key facts

Load factor
1%, from 1 GWh of reported generation; the median for 11 petcoke plants in United States of America that report generation is 34%
Share of United States of America petcoke capacity
0.2% of 2,366 MW across 11 plants in this dataset
Age among peers
2 of 11 dated petcoke plants in United States of America are older

Calculated from the capacity and generation records in this dataset (WRI Global Power Plant Database (CC BY 4.0)).

Reported generation trend

2013: 0 GWh20132014: 0 GWh20142015: 0 GWh20152016: 0 GWh20162017: 0 GWh20172018: 0 GWh20182019: 1 GWh20191 GWh

Annual generation (GWh), WRI Global Power Plant Database (CC BY 4.0).

Owner

Operated by Pasadena Refining System Inc.

Local climate & thermal context

This petcoke plant generates electricity for the grid. It sits in a humid subtropical climate (Köppen Cfa) — Northern Hemisphere, latitude 29.7°N — which shapes how much energy it can produce and how its output varies through the year.

20.8°Cannual mean temp
541heating degree-days (base 18°C)
1,570cooling degree-days (base 18°C)
8 melevation

Monthly mean temperature

J: 12 °CJF: 13 °CFM: 17 °CMA: 20 °CAM: 24 °CMJ: 27 °CJJ: 28 °CJA: 28 °CAS: 26 °CSO: 22 °CON: 17 °CND: 13 °CD28 °C

Heating degree-days here run 78% below the median power plant in this dataset — a proxy for how much extra energy heated equipment must replace through its surfaces in winter.

Climate heat-demand index: 21/100 — this site sits in the bottom third of the power plants we cover by heating degree-days.

Climate normals: WorldClim 2.1 (1970–2000 monthly normals, 10 arc-min, CC BY 4.0); zone: Köppen-Geiger world climate classification (Kottek et al. 2006, 0.5° grid). Degree-days & heat-demand index computed by PowerAtlas — a modelled heat-demand proxy, not a measured site figure.

Site climate & environmental severity

This site sits in an aggressive, high-corrosion environment (estimated ISO 9223 class C5 — Very high), with marine salt corrosion the leading environmental stress.

C5ISO 9223 corrosivity (indicative)
50/100environmental-severity index
16.9°Cseasonal temperature swing
44 kmdistance to coast

Indicative estimate via the ISO 9223:2012 informative method (atmospheric corrosivity from temperature, time-of-wetness and airborne salinity), using WorldClim climate normals, the Köppen-Geiger class and coast distance. Indicative, not a measured corrosion rate.

How it compares & nearby plants

The #11 largest petcoke power plant of 11 in United States of America by capacity.

United States of America has 11 petcoke power plants in this dataset, together about 2,366 MW of capacity.

Nearby power plants

Location

Coordinates 29.7233, -95.2103 from WRI Global Power Plant Database (CC BY 4.0). View on OpenStreetMap.

Frequently asked questions

What type of power plant is PRSI FCC Generator?

PRSI FCC Generator is a 4.7 MW petcoke power plant in Texas, United States of America, commissioned in 1979.

How much electricity does PRSI FCC Generator generate?

PRSI FCC Generator generates about 1 GWh of electricity per year.

Who operates PRSI FCC Generator?

PRSI FCC Generator is operated by Pasadena Refining System Inc.

Built from open public data; no personal information. Operate this site? Request a correction or removal.