Home / Asia / Indonesia / Palembang Timur power station

Palembang Timur power station

Gas power plant in South Sumatra, Indonesia. Approximate location -2.926817, 104.867665.

GasSouth SumatraIndonesiaCCGT · HRSG

Palembang Timur power station is a 150 MW gas power station in South Sumatra, Indonesia. It is operated by PT Asrigita Prasarana [100%]. Based on its capacity (estimated), it can supply roughly 169k homes (estimated). It ranks #215 of 401 Indonesia power plants by installed capacity. Commissioned in 2004, it is around 22 years old — relatively modern. In context, gas supplies about 18.5% of Indonesia's electricity; the national grid averages 680 gCO₂/kWh (18.1% low-carbon) (2024).

150MW installed capacity
1HRSG unit(s)
168,942homes powered (est.)
2004commissioned (~22 yrs)

Plant data: WRI Global Power Plant Database (CC BY 4.0), id GOGPT_palembangtimur_indone.

Data status

Known data

FacilityPalembang Timur power station GEM-GOGPT
CountryIndonesia · South Sumatra GEM-GOGPT
Coordinates-2.926817, 104.867665 GEM-GOGPT
FuelGas GEM-GOGPT
MW installed capacity150 MW GEM · 2026 · L100000405286; operating plant capacity
OwnerPT Asrigita Prasarana [100%] GEM-GOGPT
Commissioned2004 GEM-GOGPT
TechnologyCCGT · HRSG GEM-GOGPT

Calculated from dataset

CO₂ emissions236,520 t CO₂·a⁻¹ calculated
Capacity rank in country#215 / 401 calculated
Fuel-specific rank in country#70 / 138 calculated
Capacity vs country/fuel peers1.00× · 150 MW · n=138 calculated
Homes-powered equivalent168,942 calculated
Environmental severityC4 · 42/100 derived from coordinates

Not available

GWh reported / yrNot available not in dataset

Known, modelled and calculated values are kept separate. Missing fields are shown as unavailable.

Data provenance

The capacity and/or fuel fields on this page include a source-backed provenance label from GEM, an official registry, Wikidata, OSM, or a cross-source match.

capacity: GEM · 2026 · L100000405286; fuel: GEM GOGPT

In context: how this plant compares

At 150 MW, Palembang Timur power station is around the median gas plant in Indonesia (150 MW). Technically it is described as CCGT; combined-cycle with a heat-recovery steam generator (HRSG). Gas plants burn natural gas either in open-cycle turbines for fast peaking, or in combined-cycle units that recover exhaust heat in an HRSG to reach roughly 55–62% efficiency — the cleanest-burning fossil option.

Capacity comparison computed from the WRI Global Power Plant Database; fuel-type context is general engineering background.

Capacity vs largest gas plants in Indonesia

Batubara power station: 4,800 MW5kBatubara p…Sujiawumei LNG power station: 2,400 MW2kSujiawumei…PLTGU Jawa-1 power station: 1,760 MW2kPLTGU Jawa…PLTGU Gresik: 1,579 MW2kPLTGU Gres…PLTGU Priok Block 1 2: 1,180 MW1kPLTGU Prio…PLTGU Tambak Lorok: 1,034 MW1kPLTGU Tamb…Jawa-4 power station: 1,000 MW1kJawa-4 pow…Jawa-5 power station: 1,000 MW1kJawa-5 pow…

Installed capacity (MW), WRI Global Power Plant Database (CC BY 4.0).

Owner

Operated by PT Asrigita Prasarana [100%].

Climate zone & how it works

This gas plant burns natural gas in a turbine — often in a combined-cycle setup — to generate electricity. It sits in a tropical rainforest climate (Köppen Af) — Southern Hemisphere, latitude 2.9°S — which shapes how much energy it can produce and how its output varies through the year.

~26°Ctypical annual mean
~27°Ctypical warm-season mean
Tropical rainforest: hot and humid year-round with little seasonal variation

Climate zone & typical temperatures: Köppen-Geiger world climate classification (Kottek et al. 2006, 0.5° grid).

Site climate & environmental severity

For a plant’s outdoor hardware — heat-recovery steam generators (HRSG), expansion joints, valves, flanges and their insulation — the local climate sets how fast unprotected steel and coatings degrade. This site sits in a corrosive environment (estimated ISO 9223 class C4 — High), with humidity / wetness the leading environmental stress.

C4ISO 9223 corrosivity (indicative)
42/100environmental-severity index
1.1°Cseasonal temperature swing
104 kmdistance to coast

Higher environmental severity is exactly where protective removable insulation pays back most: a sheltered micro-climate slows corrosion, UV and thermal-cycling damage and extends outdoor hardware service life. This is an indicative site-climate context — not a condition assessment of any specific plant or operator.

Indicative estimate via the ISO 9223:2012 informative method (atmospheric corrosivity from temperature, time-of-wetness and airborne salinity), using WorldClim climate normals, the Köppen-Geiger class and coast distance. Indicative, not a measured corrosion rate.

How it compares & nearby plants

The #70 largest gas power plant of 138 in Indonesia by capacity.

Indonesia has 138 gas power plants in this dataset, together about 44,657 MW of capacity.

Nearby power plants

Location

Coordinates -2.926817, 104.867665 from WRI Global Power Plant Database (CC BY 4.0). View on OpenStreetMap.

Frequently asked questions

What type of power plant is Palembang Timur power station?

Palembang Timur power station is a 150 MW gas power plant in South Sumatra, Indonesia, commissioned in 2004.

How many homes can Palembang Timur power station power?

Its output is enough to supply roughly 168,942 homes (estimated).

Who operates Palembang Timur power station?

Palembang Timur power station is operated by PT Asrigita Prasarana [100%].

Built from open public data; no personal information. Operate this site? Request a correction or removal.