Home / North America / United States of America / Oxnard Wastewater Treatment Plant

Oxnard Wastewater Treatment Plant — United States of America

Biomass power plant in California, United States of America. Approximate location 34.1405, -119.1845.

BiomassCaliforniaUnited States of America

Oxnard Wastewater Treatment Plant is a 1.5 MW biomass power plant in California, United States of America. It is operated by Oxnard City of. Based on reported annual generation of 6 GWh, it can supply roughly 1.8k homes. It ranks #9828 of 10,884 United States of America power plants by installed capacity. Commissioned in 1981, it is around 45 years old — long-established. In context, biomass supplies about 1.0% of United States of America's electricity; the national grid averages 384 gCO₂/kWh (43.0% low-carbon) (2025).

1.5MW installed capacity
6GWh reported / yr
1,828homes powered
1981commissioned (~45 yrs)

Plant data: WRI Global Power Plant Database (CC BY 4.0), id USA0050224.

Data status

Known data

FacilityOxnard Wastewater Treatment Plant WRI
CountryUnited States of America · California WRI
Coordinates34.1405, -119.1845 WRI
FuelBiomass WRI
MW installed capacity1.5 MW Wikidata P2109; installed/nameplate capacity
Verification noteQuality label backfilled from existing source-backed capacity provenance on 2026-07-05; capacity value was not changed. source-verified
OwnerOxnard City of WRI
Commissioned1981 WRI
GWh reported / yr6 GWh·a⁻¹ WRI

Calculated from dataset

Capacity rank in country#9828 / 10884 calculated
Fuel-specific rank in country#160 / 184 calculated
Capacity vs country/fuel peers0.08× · 17.9 MW · n=184 calculated
Homes-powered equivalent1,828 calculated from reported generation
Climate16.0°C · HDD 860 derived from coordinates
Environmental severityC4 · 36/100 derived from coordinates

Not available

TechnologyNot available not in dataset
CO₂ emissionsNot available not in dataset

Known, modelled and calculated values are kept separate. Missing fields are shown as unavailable.

Data provenance

Source of the capacity and fuel values:

capacity: Wikidata P2109; fuel: WRI GPPD

In context: how this plant compares

At 1.5 MW, Oxnard Wastewater Treatment Plant is below the median biomass plant in United States of America (17.9 MW). Biomass plants burn organic material such as wood, residues or waste-derived fuel to raise steam; they are dispatchable and counted as low-carbon where the feedstock is sustainably sourced.

Capacity comparison computed from the WRI Global Power Plant Database; fuel-type context is general engineering background.

Key facts

Load factor
49%, from 6 GWh of reported generation; the median for 144 biomass plants in United States of America that report generation is 53%
Generation trend
6 GWh in 2013 and 6 GWh in 2019 (+0%)
Highest and lowest year
2013: 6 GWh; 2017: 6 GWh
Share of United States of America biomass capacity
less than 0.1% of 6,324 MW across 184 plants in this dataset
Age among peers
34 of 153 dated biomass plants in United States of America are older

Calculated from the capacity and generation records in this dataset (WRI Global Power Plant Database (CC BY 4.0)).

Reported generation trend

2013: 6 GWh20132014: 6 GWh20142015: 6 GWh20152016: 6 GWh20162017: 6 GWh20172018: 6 GWh20182019: 6 GWh20196 GWh

Annual generation (GWh), WRI Global Power Plant Database (CC BY 4.0).

Owner

Operated by Oxnard City of.

Local climate & thermal context

This biomass plant burns organic material (wood, residues) to raise steam for a turbine. It sits in a warm-summer Mediterranean climate (Köppen Csb) — Northern Hemisphere, latitude 34.1°N — which shapes how much energy it can produce and how its output varies through the year.

16.0°Cannual mean temp
860heating degree-days (base 18°C)
146cooling degree-days (base 18°C)
86 melevation

Monthly mean temperature

J: 13 °CJF: 13 °CFM: 14 °CMA: 15 °CAM: 16 °CMJ: 17 °CJJ: 19 °CJA: 20 °CAS: 20 °CSO: 18 °CON: 15 °CND: 13 °CD20 °C

Heating degree-days here run 65% below the median power plant in this dataset — a proxy for how much extra energy heated equipment must replace through its surfaces in winter.

Climate heat-demand index: 25/100 — this site sits in the bottom third of the power plants we cover by heating degree-days.

Climate normals: WorldClim 2.1 (1970–2000 monthly normals, 10 arc-min, CC BY 4.0); zone: Köppen-Geiger world climate classification (Kottek et al. 2006, 0.5° grid). Degree-days & heat-demand index computed by PowerAtlas — a modelled heat-demand proxy, not a measured site figure.

Site climate & environmental severity

This site sits in a corrosive environment (estimated ISO 9223 class C4 — High), with marine corrosion the leading environmental stress.

C4ISO 9223 corrosivity (indicative)
36/100environmental-severity index
7.0°Cseasonal temperature swing
21 kmdistance to coast

Indicative estimate via the ISO 9223:2012 informative method (atmospheric corrosivity from temperature, time-of-wetness and airborne salinity), using WorldClim climate normals, the Köppen-Geiger class and coast distance. Indicative, not a measured corrosion rate.

How it compares & nearby plants

The #160 largest biomass power plant of 184 in United States of America by capacity.

United States of America has 184 biomass power plants in this dataset, together about 6,324 MW of capacity.

Nearby power plants

Location

Coordinates 34.1405, -119.1845 from WRI Global Power Plant Database (CC BY 4.0). View on OpenStreetMap.

Frequently asked questions

What type of power plant is Oxnard Wastewater Treatment Plant?

Oxnard Wastewater Treatment Plant is a 1.5 MW biomass power plant in California, United States of America, commissioned in 1981.

How much electricity does Oxnard Wastewater Treatment Plant generate?

Oxnard Wastewater Treatment Plant generates about 6 GWh of electricity per year.

Who operates Oxnard Wastewater Treatment Plant?

Oxnard Wastewater Treatment Plant is operated by Oxnard City of.

Built from open public data; no personal information. Operate this site? Request a correction or removal.