Mountain View

Waste power plant in Pennsylvania, United States of America. Approximate location 39.8014, -77.7883.

WastePennsylvaniaUnited States of America

Mountain View is a 14 MW waste power plant in Pennsylvania, United States of America. It is operated by Industrial Power Generating Company LLC. Based on reported annual generation of 41 GWh, it can supply roughly 12k homes. It ranks #5237 of 10,938 United States of America power plants by installed capacity. Commissioned in 2003, it is around 23 years old — relatively modern. In context, the national grid averages 384 gCO₂/kWh (43.0% low-carbon) (2025).

14Source-backed capacity
41GWh reported / yr
11,800homes powered
2003commissioned (~23 yrs)

Plant data: WRI Global Power Plant Database (CC BY 4.0), id USA0056687.

Data status

Known data

FacilityMountain View WRI
CountryUnited States of America · Pennsylvania WRI
Coordinates39.8014, -77.7883 WRI
FuelWaste WRI
MW installed capacity14 MW WRI source record; scope not independently normalised
OwnerIndustrial Power Generating Company LLC WRI
Commissioned2003 WRI
GWh reported / yr41 GWh/yr WRI

Calculated from dataset

Capacity rank in country#5237 of 10938 calculated
Fuel-specific rank in country#179 of 551 calculated
Capacity vs country/fuel peers2.18× · 7 MW median · 551 peers calculated
Homes-powered equivalent11,800 calculated from reported generation
Climate11.5°C · HDD 2,809 derived from coordinates
Environmental severityC2 · 33/100 derived from coordinates

Not available

TechnologyNot available not in dataset
GWh reported / yrNot available not in dataset
CO₂ emissionsNot available not in dataset

Known, modelled and calculated values are kept separate. Missing fields are shown as unavailable.

Data provenance

The capacity and/or fuel fields on this page include a source-backed provenance label from GEM, an official registry, Wikidata, OSM, or a cross-source match.

capacity: Wikidata P2109 nameplate capacity; fuel: WRI source-record fuel

In context: how this plant compares

At 14 MW, Mountain View is well above the median waste plant in United States of America (7 MW). Waste-to-energy plants burn municipal solid waste to generate electricity and heat, cutting landfill volume while recovering energy from residual waste.

Capacity comparison computed from the WRI Global Power Plant Database; fuel-type context is general engineering background.

Reported generation trend

2013: 10 GWh20132014: 14 GWh20142015: 11 GWh20152016: 23 GWh20162017: 24 GWh20172018: 31 GWh20182019: 41 GWh201941 GWh

Annual generation (GWh), WRI Global Power Plant Database (CC BY 4.0).

Owner

Operated by Industrial Power Generating Company LLC. All plants by this company →

Local climate & thermal context

This waste plant recovers energy by combusting municipal or industrial waste. It sits in a humid subtropical climate (Köppen Cfa) — Northern Hemisphere, latitude 39.8°N — which shapes how much energy it can produce and how its output varies through the year.

11.5°Cannual mean temp
2,809heating degree-days (base 18°C)
448cooling degree-days (base 18°C)
177 melevation

Monthly mean temperature

J: -2 °CJF: 0 °CFM: 5 °CMA: 11 °CAM: 16 °CMJ: 21 °CJJ: 24 °CJA: 23 °CAS: 19 °CSO: 12 °CON: 7 °CND: 1 °CD24 °C

Heating degree-days here run 14% above the median power plant in this dataset — a proxy for how much extra energy heated equipment must replace through its surfaces in winter.

Climate heat-demand index: 57/100 — this site sits in the mid third of the power plants we cover by heating degree-days.

Climate normals: WorldClim 2.1 (1970–2000 monthly normals, 10 arc-min, CC BY 4.0); zone: Köppen-Geiger world climate classification (Kottek et al. 2006, 0.5° grid). Degree-days & heat-demand index computed by PowerAtlas — a modelled heat-demand proxy, not a measured site figure.

Site climate & environmental severity

For a plant’s outdoor hardware — heat-recovery steam generators (HRSG), expansion joints, valves, flanges and their insulation — the local climate sets how fast unprotected steel and coatings degrade. This site sits in a mild atmospheric environment (estimated ISO 9223 class C2 — Low), with humidity / wetness the leading environmental stress.

C2ISO 9223 corrosivity (indicative)
33/100environmental-severity index
25.2°Cseasonal temperature swing
247 kmdistance to coast

Higher environmental severity is exactly where protective removable insulation pays back most: a sheltered micro-climate slows corrosion, UV and thermal-cycling damage and extends outdoor hardware service life. This is an indicative site-climate context — not a condition assessment of any specific plant or operator.

Indicative estimate via the ISO 9223:2012 informative method (atmospheric corrosivity from temperature, time-of-wetness and airborne salinity), using WorldClim climate normals, the Köppen-Geiger class and coast distance. Indicative, not a measured corrosion rate.

How it compares & nearby plants

The #179 largest waste power plant of 551 in United States of America by capacity.

United States of America has 551 waste power plants in this dataset, together about 10,154 MW of capacity.

Nearby power plants

Location

Coordinates 39.8014, -77.7883 from WRI Global Power Plant Database (CC BY 4.0). View on OpenStreetMap.

Frequently asked questions

What type of power plant is Mountain View?

Mountain View is a 14 MW source-record waste power plant in Pennsylvania, United States of America, commissioned in 2003.

How much electricity does Mountain View generate?

Mountain View generates about 41 GWh of electricity per year.

How many homes can Mountain View power?

Its output is enough to supply roughly 11,800 homes.

Who operates Mountain View?

Mountain View is operated by Industrial Power Generating Company LLC.

Built from open public data; no personal information. Operate this site? Request a correction or removal.