Home / North America / United States of America / Mosaic Co Tampa Facility

Mosaic Co Tampa Facility — United States of America

Cogeneration power plant in Florida, United States of America. Approximate location 27.8605, -82.3903.

CogenerationFloridaUnited States of America

Mosaic Co Tampa Facility is a 72.4 MW cogeneration power plant in Florida, United States of America. It is operated by Mosaic Company. Based on reported annual generation of 268 GWh, it can supply roughly 77k homes. It ranks #3216 of 10,884 United States of America power plants by installed capacity. Commissioned in 1993, it is around 33 years old — long-established. In context, the national grid averages 384 gCO₂/kWh (43.0% low-carbon) (2025).

72.4MW installed capacity
268GWh reported / yr
76,571homes powered
1993commissioned (~33 yrs)

Plant data: WRI Global Power Plant Database (CC BY 4.0), id USA0010204.

Data status

Known data

FacilityMosaic Co Tampa Facility WRI
CountryUnited States of America · Florida WRI
Coordinates27.8605, -82.3903 WRI
FuelCogeneration WRI
MW installed capacity72.4 MW Wikidata P2109; installed/nameplate capacity
Verification noteQuality label backfilled from existing source-backed capacity provenance on 2026-07-05; capacity value was not changed. source-verified
OwnerMosaic Company WRI
Commissioned1993 WRI
GWh reported / yr268 GWh·a⁻¹ WRI

Calculated from dataset

Capacity rank in country#3216 / 10884 calculated
Fuel-specific rank in country#4 / 34 calculated
Capacity vs country/fuel peers2.78× · 26 MW · n=34 calculated
Homes-powered equivalent76,571 calculated from reported generation
Climate22.6°C · HDD 120 derived from coordinates
Environmental severityC5 · 53/100 derived from coordinates

Not available

TechnologyNot available not in dataset
CO₂ emissionsNot available not in dataset

Known, modelled and calculated values are kept separate. Missing fields are shown as unavailable.

Data provenance

Source of the capacity and fuel values:

capacity: Wikidata P2109; fuel: WRI GPPD

In context: how this plant compares

At 72.4 MW, Mosaic Co Tampa Facility is well above the median cogeneration plant in United States of America (26 MW). This facility converts its energy source into electricity for the grid; its capacity, fuel type and location determine its role in the national power mix.

Capacity comparison computed from the WRI Global Power Plant Database; fuel-type context is general engineering background.

Key facts

Load factor
42%, from 268 GWh of reported generation; the median for 31 cogeneration plants in United States of America that report generation is 47%
Share of United States of America cogeneration capacity
7.0% of 1,037 MW across 34 plants in this dataset
Age among peers
14 of 34 dated cogeneration plants in United States of America are older

Calculated from the capacity and generation records in this dataset (WRI Global Power Plant Database (CC BY 4.0)).

Reported generation trend

2013: 0 GWh20132014: 0 GWh20142015: 0 GWh20152016: 0 GWh20162017: 0 GWh20172018: 0 GWh20182019: 268 GWh2019268 GWh

Annual generation (GWh), WRI Global Power Plant Database (CC BY 4.0).

Owner

Operated by Mosaic Company.

Local climate & thermal context

This cogeneration plant produces electricity and useful heat together for higher fuel efficiency. It sits in a humid subtropical climate (Köppen Cfa) — Northern Hemisphere, latitude 27.9°N — which shapes how much energy it can produce and how its output varies through the year.

22.6°Cannual mean temp
120heating degree-days (base 18°C)
1,800cooling degree-days (base 18°C)
10 melevation

Monthly mean temperature

J: 16 °CJF: 17 °CFM: 20 °CMA: 22 °CAM: 25 °CMJ: 27 °CJJ: 28 °CJA: 28 °CAS: 27 °CSO: 24 °CON: 20 °CND: 17 °CD28 °C

Heating degree-days here run 95% below the median power plant in this dataset — a proxy for how much extra energy heated equipment must replace through its surfaces in winter.

Climate heat-demand index: 15/100 — this site sits in the bottom third of the power plants we cover by heating degree-days.

Climate normals: WorldClim 2.1 (1970–2000 monthly normals, 10 arc-min, CC BY 4.0); zone: Köppen-Geiger world climate classification (Kottek et al. 2006, 0.5° grid). Degree-days & heat-demand index computed by PowerAtlas — a modelled heat-demand proxy, not a measured site figure.

Site climate & environmental severity

This site sits in an aggressive, high-corrosion environment (estimated ISO 9223 class C5 — Very high), with marine salt corrosion the leading environmental stress.

C5ISO 9223 corrosivity (indicative)
53/100environmental-severity index
11.9°Cseasonal temperature swing
11 kmdistance to coast

Indicative estimate via the ISO 9223:2012 informative method (atmospheric corrosivity from temperature, time-of-wetness and airborne salinity), using WorldClim climate normals, the Köppen-Geiger class and coast distance. Indicative, not a measured corrosion rate.

How it compares & nearby plants

The #4 largest cogeneration power plant of 34 in United States of America by capacity.

United States of America has 34 cogeneration power plants in this dataset, together about 1,037 MW of capacity.

Nearby power plants

Location

Coordinates 27.8605, -82.3903 from WRI Global Power Plant Database (CC BY 4.0). View on OpenStreetMap.

Frequently asked questions

What type of power plant is Mosaic Co Tampa Facility?

Mosaic Co Tampa Facility is a 72.4 MW cogeneration power plant in Florida, United States of America, commissioned in 1993.

How much electricity does Mosaic Co Tampa Facility generate?

Mosaic Co Tampa Facility generates about 268 GWh of electricity per year.

Who operates Mosaic Co Tampa Facility?

Mosaic Co Tampa Facility is operated by Mosaic Company.

Built from open public data; no personal information. Operate this site? Request a correction or removal.