Home / North America / United States of America / Martinez Sulfuric Acid Regeneration Plt

Martinez Sulfuric Acid Regeneration Plt

Cogeneration power plant in California, United States of America. Approximate location 38.0314, -122.1139.

CogenerationCaliforniaUnited States of America

Martinez Sulfuric Acid Regeneration Plt is a 4 MW cogeneration power plant in California, United States of America. It is operated by Eco Services Corp.. Based on reported annual generation of 13 GWh, it can supply roughly 3.7k homes. It ranks #7633 of 10,938 United States of America power plants by installed capacity. Commissioned in 1978, it is around 48 years old — long-established. In context, the national grid averages 384 gCO₂/kWh (43.0% low-carbon) (2025).

4Source-backed capacity
13GWh reported / yr
3,742homes powered
1978commissioned (~48 yrs)

Plant data: WRI Global Power Plant Database (CC BY 4.0), id USA0052063.

Data status

Known data

FacilityMartinez Sulfuric Acid Regeneration Plt WRI
CountryUnited States of America · California WRI
Coordinates38.0314, -122.1139 WRI
FuelCogeneration WRI
MW installed capacity4 MW WRI source record; scope not independently normalised
OwnerEco Services Corp. WRI
Commissioned1978 WRI
GWh reported / yr13 GWh/yr WRI

Calculated from dataset

Capacity rank in country#7633 of 10938 calculated
Fuel-specific rank in country#32 of 34 calculated
Capacity vs country/fuel peers0.15× · 26 MW median · 34 peers calculated
Homes-powered equivalent3,742 calculated from reported generation
Climate15.2°C · HDD 1,401 derived from coordinates
Environmental severityC3 · 32/100 derived from coordinates

Not available

TechnologyNot available not in dataset
GWh reported / yrNot available not in dataset
CO₂ emissionsNot available not in dataset

Known, modelled and calculated values are kept separate. Missing fields are shown as unavailable.

Data provenance

The capacity and/or fuel fields on this page include a source-backed provenance label from GEM, an official registry, Wikidata, OSM, or a cross-source match.

capacity: Wikidata P2109 nameplate capacity; fuel: WRI source-record fuel

In context: how this plant compares

At 4 MW, Martinez Sulfuric Acid Regeneration Plt is below the median cogeneration plant in United States of America (26 MW). This facility converts its energy source into electricity for the grid; its capacity, fuel type and location determine its role in the national power mix.

Capacity comparison computed from the WRI Global Power Plant Database; fuel-type context is general engineering background.

Reported generation trend

2013: 1 GWh20132014: 1 GWh20142015: 0 GWh20152016: 0 GWh20162017: 0 GWh20172018: 0 GWh20182019: 13 GWh201913 GWh

Annual generation (GWh), WRI Global Power Plant Database (CC BY 4.0).

Owner

Operated by Eco Services Corp..

Local climate & thermal context

This cogeneration plant produces electricity and useful heat together for higher fuel efficiency. It sits in a warm-summer Mediterranean climate (Köppen Csb) — Northern Hemisphere, latitude 38.0°N — which shapes how much energy it can produce and how its output varies through the year.

15.2°Cannual mean temp
1,401heating degree-days (base 18°C)
396cooling degree-days (base 18°C)
299 melevation

Monthly mean temperature

J: 8 °CJF: 10 °CFM: 11 °CMA: 14 °CAM: 16 °CMJ: 20 °CJJ: 22 °CJA: 22 °CAS: 21 °CSO: 18 °CON: 12 °CND: 8 °CD22 °C

Heating degree-days here run 43% below the median power plant in this dataset — a proxy for how much extra energy heated equipment must replace through its surfaces in winter.

Climate heat-demand index: 32/100 — this site sits in the bottom third of the power plants we cover by heating degree-days.

Climate normals: WorldClim 2.1 (1970–2000 monthly normals, 10 arc-min, CC BY 4.0); zone: Köppen-Geiger world climate classification (Kottek et al. 2006, 0.5° grid). Degree-days & heat-demand index computed by PowerAtlas — a modelled heat-demand proxy, not a measured site figure.

Site climate & environmental severity

For a plant’s outdoor hardware — heat-recovery steam generators (HRSG), expansion joints, valves, flanges and their insulation — the local climate sets how fast unprotected steel and coatings degrade. This site sits in a moderately corrosive environment (estimated ISO 9223 class C3 — Medium), with humidity / wetness the leading environmental stress.

C3ISO 9223 corrosivity (indicative)
32/100environmental-severity index
14.1°Cseasonal temperature swing
80 kmdistance to coast

Higher environmental severity is exactly where protective removable insulation pays back most: a sheltered micro-climate slows corrosion, UV and thermal-cycling damage and extends outdoor hardware service life. This is an indicative site-climate context — not a condition assessment of any specific plant or operator.

Indicative estimate via the ISO 9223:2012 informative method (atmospheric corrosivity from temperature, time-of-wetness and airborne salinity), using WorldClim climate normals, the Köppen-Geiger class and coast distance. Indicative, not a measured corrosion rate.

How it compares & nearby plants

The #32 largest cogeneration power plant of 34 in United States of America by capacity.

United States of America has 34 cogeneration power plants in this dataset, together about 1,037 MW of capacity.

Nearby power plants

Location

Coordinates 38.0314, -122.1139 from WRI Global Power Plant Database (CC BY 4.0). View on OpenStreetMap.

Frequently asked questions

What type of power plant is Martinez Sulfuric Acid Regeneration Plt?

Martinez Sulfuric Acid Regeneration Plt is a 4 MW source-record cogeneration power plant in California, United States of America, commissioned in 1978.

How much electricity does Martinez Sulfuric Acid Regeneration Plt generate?

Martinez Sulfuric Acid Regeneration Plt generates about 13 GWh of electricity per year.

How many homes can Martinez Sulfuric Acid Regeneration Plt power?

Its output is enough to supply roughly 3,742 homes.

Who operates Martinez Sulfuric Acid Regeneration Plt?

Martinez Sulfuric Acid Regeneration Plt is operated by Eco Services Corp..

Built from open public data; no personal information. Operate this site? Request a correction or removal.