Home / North America / United States of America / Manchief Electric Generating Station

Manchief Electric Generating Station

Gas power plant in Colorado, United States of America. Approximate location 40.2171, -103.685.

GasColoradoUnited States of AmericaOCGTCO₂ measured

Manchief Electric Generating Station is a 300 MW gas power station in Colorado, United States of America. It is operated by Manchief Power Co LLC. Based on reported annual generation of 333 GWh, it can supply roughly 95k homes. It ranks #1630 of 10,938 United States of America power plants by installed capacity. Commissioned in 2000, it is around 26 years old — long-established. Its annual emissions of 206,071 t CO₂/yr (US EPA GHGRP) are equivalent to about 48k cars driven for a year. In context, gas supplies about 40.0% of United States of America's electricity; the national grid averages 384 gCO₂/kWh (43.0% low-carbon) (2025).

300Source-backed capacity
333GWh reported / yr
95,085homes powered
206,071t CO₂ / yr (US EPA GHGRP)
2000commissioned (~26 yrs)

Plant data: WRI Global Power Plant Database (CC BY 4.0), id USA0055127.

Data status

Known data

FacilityManchief Electric Generating Station WRI
CountryUnited States of America · Colorado WRI
Coordinates40.2171, -103.685 WRI
FuelGas WRI
MW installed capacity300 MW WRI source record; scope not independently normalised
OwnerManchief Power Co LLC WRI
Commissioned2000 WRI
TechnologyOCGT WRI
GWh reported / yr333 GWh/yr WRI
CO₂ emissions206,071 t CO₂/yr measured · US EPA GHGRP

Calculated from dataset

Capacity rank in country#1630 of 10938 calculated
Fuel-specific rank in country#786 of 2165 calculated
Capacity vs country/fuel peers2.48× · 121 MW median · 2165 peers calculated
Homes-powered equivalent95,085 calculated from reported generation
Climate9.9°C · HDD 3,360 derived from coordinates
Environmental severityC1 · 39/100 derived from coordinates

Not available

GWh reported / yrNot available not in dataset

Known, modelled and calculated values are kept separate. Missing fields are shown as unavailable.

Data provenance

The capacity and/or fuel fields on this page include a source-backed provenance label from GEM, an official registry, Wikidata, OSM, or a cross-source match.

capacity: GEM tracker 2026 (location L100000402076); fuel: WRI source-record fuel

In context: how this plant compares

At 300 MW, Manchief Electric Generating Station is well above the median gas plant in United States of America (121 MW). Technically it is described as OCGT. Gas plants burn natural gas either in open-cycle turbines for fast peaking, or in combined-cycle units that recover exhaust heat in an HRSG to reach roughly 55–62% efficiency — the cleanest-burning fossil option.

Capacity comparison computed from the WRI Global Power Plant Database; fuel-type context is general engineering background.

206,071 t CO₂/yr — in everyday terms

This facility's annual emissions are roughly equivalent to:

48kpassenger cars driven for a year
27khomes' yearly energy use
3.4 milliontree seedlings grown 10 years to absorb it

Equivalencies via US EPA Greenhouse Gas Equivalencies; emissions per US EPA GHGRP (measured for US EPA/EU ETS, modelled for Climate TRACE).

Reported generation trend

2013: 450 GWh20132014: 296 GWh20142015: 187 GWh20152016: 77 GWh20162017: 112 GWh20172018: 300 GWh20182019: 333 GWh2019450 GWh

Annual generation (GWh), WRI Global Power Plant Database (CC BY 4.0).

Owner

Operated by Manchief Power Co LLC.

Local climate & thermal context

This gas plant burns natural gas in a turbine — often in a combined-cycle setup — to generate electricity. It sits in a cold semi-arid steppe climate (Köppen BSk) — Northern Hemisphere, latitude 40.2°N — which shapes how much energy it can produce and how its output varies through the year.

9.9°Cannual mean temp
3,360heating degree-days (base 18°C)
410cooling degree-days (base 18°C)
1,346 melevation

Monthly mean temperature

J: -4 °CJF: 0 °CFM: 4 °CMA: 9 °CAM: 15 °CMJ: 20 °CJJ: 24 °CJA: 23 °CAS: 18 °CSO: 10 °CON: 2 °CND: -3 °CD24 °C

Heating degree-days here run 37% above the median power plant in this dataset — a proxy for how much extra energy heated equipment must replace through its surfaces in winter.

Climate heat-demand index: 73/100 — this site sits in the top third of the power plants we cover by heating degree-days.

A gas turbine here also runs ~0% below its ISO (15°C) rating at this annual mean (typical CCGT curve, estimate).

Climate normals: WorldClim 2.1 (1970–2000 monthly normals, 10 arc-min, CC BY 4.0); zone: Köppen-Geiger world climate classification (Kottek et al. 2006, 0.5° grid). Degree-days & heat-demand index computed by PowerAtlas — a modelled heat-demand proxy, not a measured site figure.

Site climate & environmental severity

For a plant’s outdoor hardware — heat-recovery steam generators (HRSG), expansion joints, valves, flanges and their insulation — the local climate sets how fast unprotected steel and coatings degrade. This site sits in a benign, low-corrosion environment (estimated ISO 9223 class C1 — Very low), with dust abrasion the leading environmental stress.

C1ISO 9223 corrosivity (indicative)
39/100environmental-severity index
27.9°Cseasonal temperature swing
1352 kmdistance to coast

Higher environmental severity is exactly where protective removable insulation pays back most: a sheltered micro-climate slows corrosion, UV and thermal-cycling damage and extends outdoor hardware service life. This is an indicative site-climate context — not a condition assessment of any specific plant or operator.

Indicative estimate via the ISO 9223:2012 informative method (atmospheric corrosivity from temperature, time-of-wetness and airborne salinity), using WorldClim climate normals, the Köppen-Geiger class and coast distance. Indicative, not a measured corrosion rate.

How it compares & nearby plants

The #786 largest gas power plant of 2165 in United States of America by capacity.

United States of America has 2165 gas power plants in this dataset, together about 789,950 MW of capacity.

Nearby power plants

Location

Coordinates 40.2171, -103.685 from WRI Global Power Plant Database (CC BY 4.0). View on OpenStreetMap.

Frequently asked questions

What type of power plant is Manchief Electric Generating Station?

Manchief Electric Generating Station is a 300 MW source-record gas power plant in Colorado, United States of America, commissioned in 2000.

How much electricity does Manchief Electric Generating Station generate?

Manchief Electric Generating Station generates about 333 GWh of electricity per year.

How many homes can Manchief Electric Generating Station power?

Its output is enough to supply roughly 95,085 homes.

Who operates Manchief Electric Generating Station?

Manchief Electric Generating Station is operated by Manchief Power Co LLC.

How much CO₂ does Manchief Electric Generating Station emit?

Manchief Electric Generating Station has measured emissions of about 206,071 tonnes of CO₂ per year (US EPA GHGRP).