Home / Europe / Belgium / Lillo Degussa power station

Lillo Degussa power station

Gas power plant in Antwerp, Belgium. Approximate location 51.30953, 4.30402.

GasAntwerpBelgiumCCGT · HRSG

Lillo Degussa power station is a 85 MW gas power plant in Antwerp, Belgium. It is operated by Electrabel NV/SA [100%]. Based on its capacity (estimated), it can supply roughly 96k homes (estimated). It ranks #40 of 95 Belgium power plants by installed capacity. Commissioned in 1999, it is around 27 years old — long-established. In context, gas supplies about 21.5% of Belgium's electricity; the national grid averages 150 gCO₂/kWh (72.0% low-carbon) (2025).

85MW installed capacity
2HRSG unit(s)
95,734homes powered (est.)
1999commissioned (~27 yrs)

Plant data: WRI Global Power Plant Database (CC BY 4.0), id GOGPT_lillodegussa_belgiu.

Data status

Known data

FacilityLillo Degussa power station GEM-GOGPT
CountryBelgium · Antwerp GEM-GOGPT
Coordinates51.30953, 4.30402 GEM-GOGPT
FuelGas GEM-GOGPT
MW installed capacity85 MW GEM · 2026 · L100000400030; operating plant capacity
OwnerElectrabel NV/SA [100%] GEM-GOGPT
Commissioned1999 GEM-GOGPT
TechnologyCCGT · HRSG GEM-GOGPT

Calculated from dataset

CO₂ emissions134,028 t CO₂·a⁻¹ calculated
Capacity rank in country#40 / 95 calculated
Fuel-specific rank in country#21 / 35 calculated
Capacity vs country/fuel peers0.66× · 128 MW · n=35 calculated
Homes-powered equivalent95,734 calculated
Climate10.6°C · HDD 2,710 derived from coordinates
Environmental severityC3 · 28/100 derived from coordinates

Not available

GWh reported / yrNot available not in dataset

Known, modelled and calculated values are kept separate. Missing fields are shown as unavailable.

Data provenance

The capacity and/or fuel fields on this page include a source-backed provenance label from GEM, an official registry, Wikidata, OSM, or a cross-source match.

capacity: GEM · 2026 · L100000400030; fuel: GEM GOGPT

In context: how this plant compares

At 85 MW, Lillo Degussa power station is below the median gas plant in Belgium (128 MW). Technically it is described as CCGT; combined-cycle with a heat-recovery steam generator (HRSG). Gas plants burn natural gas either in open-cycle turbines for fast peaking, or in combined-cycle units that recover exhaust heat in an HRSG to reach roughly 55–62% efficiency — the cleanest-burning fossil option.

Capacity comparison computed from the WRI Global Power Plant Database; fuel-type context is general engineering background.

Capacity vs largest gas plants in Belgium

Seraing power station: 1,170 MW1kSeraing po…Dils Energie power station: 920 MW920Dils Energ…Awirs power station: 875 MW875Awirs powe…Manage Seneffe power station: 870 MW870Manage Sen…HERDERSBRUG STEG: 465 MW465HERDERSBRU…DROGENBOS TGV: 460 MW460DROGENBOS …Amercoeur 1 R TGV: 451 MW451Amercoeur …T-power Beringen: 422 MW422T-power Be…

Installed capacity (MW), WRI Global Power Plant Database (CC BY 4.0).

Owner

Operated by Electrabel NV/SA [100%].

Local climate & thermal context

This gas plant burns natural gas in a turbine — often in a combined-cycle setup — to generate electricity. It sits in a temperate oceanic climate (Köppen Cfb) — Northern Hemisphere, latitude 51.3°N — which shapes how much energy it can produce and how its output varies through the year.

10.6°Cannual mean temp
2,710heating degree-days (base 18°C)
14cooling degree-days (base 18°C)
7 melevation

Monthly mean temperature

J: 4 °CJF: 4 °CFM: 7 °CMA: 9 °CAM: 14 °CMJ: 16 °CJJ: 18 °CJA: 18 °CAS: 15 °CSO: 11 °CON: 7 °CND: 5 °CD18 °C

Heating degree-days here run 10% above the median power plant in this dataset — a proxy for how much extra energy heated equipment must replace through its surfaces in winter.

Climate heat-demand index: 55/100 — this site sits in the mid third of the power plants we cover by heating degree-days.

A gas turbine here also runs ~0% below its ISO (15°C) rating at this annual mean (typical CCGT curve, estimate).

Climate normals: WorldClim 2.1 (1970–2000 monthly normals, 10 arc-min, CC BY 4.0); zone: Köppen-Geiger world climate classification (Kottek et al. 2006, 0.5° grid). Degree-days & heat-demand index computed by PowerAtlas — a modelled heat-demand proxy, not a measured site figure.

Site climate & environmental severity

For a plant’s outdoor hardware — heat-recovery steam generators (HRSG), expansion joints, valves, flanges and their insulation — the local climate sets how fast unprotected steel and coatings degrade. This site sits in a moderately corrosive environment (estimated ISO 9223 class C3 — Medium), with humidity / wetness the leading environmental stress.

C3ISO 9223 corrosivity (indicative)
28/100environmental-severity index
14.6°Cseasonal temperature swing
58 kmdistance to coast

Higher environmental severity is exactly where protective removable insulation pays back most: a sheltered micro-climate slows corrosion, UV and thermal-cycling damage and extends outdoor hardware service life. This is an indicative site-climate context — not a condition assessment of any specific plant or operator.

Indicative estimate via the ISO 9223:2012 informative method (atmospheric corrosivity from temperature, time-of-wetness and airborne salinity), using WorldClim climate normals, the Köppen-Geiger class and coast distance. Indicative, not a measured corrosion rate.

How it compares & nearby plants

The #21 largest gas power plant of 35 in Belgium by capacity.

Belgium has 35 gas power plants in this dataset, together about 8,938 MW of capacity.

Nearby power plants

Location

Coordinates 51.30953, 4.30402 from WRI Global Power Plant Database (CC BY 4.0). View on OpenStreetMap.

Frequently asked questions

What type of power plant is Lillo Degussa power station?

Lillo Degussa power station is a 85 MW gas power plant in Antwerp, Belgium, commissioned in 1999.

How many homes can Lillo Degussa power station power?

Its output is enough to supply roughly 95,734 homes (estimated).

Who operates Lillo Degussa power station?

Lillo Degussa power station is operated by Electrabel NV/SA [100%].

Built from open public data; no personal information. Operate this site? Request a correction or removal.