Home / North America / United States of America / LCEC Generation LLVC

LCEC Generation LLVC — United States of America

Gas power plant in New Mexico, United States of America. Approximate location 32.9781, -103.3239.

GasNew MexicoUnited States of America

LCEC Generation LLVC is a 46.5 MW gas power plant in New Mexico, United States of America. It is operated by Western Farmers Elec Coop Inc. Based on reported annual generation of 48 GWh, it can supply roughly 14k homes. It ranks #3789 of 10,884 United States of America power plants by installed capacity. Commissioned in 2012, it is around 14 years old — relatively modern. In context, gas supplies about 40.0% of United States of America's electricity; the national grid averages 384 gCO₂/kWh (43.0% low-carbon) (2025).

46.5MW installed capacity
48GWh reported / yr
13,742homes powered
2012commissioned (~14 yrs)

Plant data: WRI Global Power Plant Database (CC BY 4.0), id USA0057872.

Data status

Known data

FacilityLCEC Generation LLVC WRI
CountryUnited States of America · New Mexico WRI
Coordinates32.9781, -103.3239 WRI
FuelGas WRI
MW installed capacity46.5 MW Wikidata P2109; installed/nameplate capacity
Verification noteQuality label backfilled from existing source-backed capacity provenance on 2026-07-05; capacity value was not changed. source-verified
OwnerWestern Farmers Elec Coop Inc WRI
Commissioned2012 WRI
GWh reported / yr48 GWh·a⁻¹ WRI

Calculated from dataset

CO₂ emissions19,240 t CO₂·a⁻¹ calculated
Capacity rank in country#3789 / 10884 calculated
Fuel-specific rank in country#1413 / 2165 calculated
Capacity vs country/fuel peers0.38× · 121.2 MW · n=2165 calculated
Homes-powered equivalent13,742 calculated from reported generation
Climate15.6°C · HDD 1,697 derived from coordinates
Environmental severityC1 · 40/100 derived from coordinates

Not available

TechnologyNot available not in dataset

Known, modelled and calculated values are kept separate. Missing fields are shown as unavailable.

Data provenance

Source of the capacity and fuel values:

capacity: Wikidata P2109; fuel: WRI GPPD

In context: how this plant compares

At 46.5 MW, LCEC Generation LLVC is below the median gas plant in United States of America (121.2 MW). Gas plants burn natural gas either in open-cycle turbines for fast peaking, or in combined-cycle units that recover exhaust heat in an HRSG to reach roughly 55–62% efficiency — the cleanest-burning fossil option.

Capacity comparison computed from the WRI Global Power Plant Database; fuel-type context is general engineering background.

Key facts

Load factor
12%, from 48 GWh of reported generation; the median for 1622 gas plants in United States of America that report generation is 26%
Generation trend
13 GWh in 2013 and 48 GWh in 2019 (+259%)
Highest and lowest year
2014: 67 GWh; 2013: 13 GWh
Share of United States of America gas capacity
less than 0.1% of 789,950 MW across 2,165 plants in this dataset
Age among peers
1,518 of 1,973 dated gas plants in United States of America are older

Calculated from the capacity and generation records in this dataset (WRI Global Power Plant Database (CC BY 4.0)).

Reported generation trend

2013: 13 GWh20132014: 67 GWh20142015: 31 GWh20152016: 54 GWh20162017: 40 GWh20172018: 46 GWh20182019: 48 GWh201967 GWh

Annual generation (GWh), WRI Global Power Plant Database (CC BY 4.0).

Local climate & thermal context

This gas plant burns natural gas in a turbine — often in a combined-cycle setup — to generate electricity. It sits in a cold semi-arid steppe climate (Köppen BSk) — Northern Hemisphere, latitude 33.0°N — which shapes how much energy it can produce and how its output varies through the year.

15.6°Cannual mean temp
1,697heating degree-days (base 18°C)
841cooling degree-days (base 18°C)
1,161 melevation

Monthly mean temperature

J: 5 °CJF: 7 °CFM: 11 °CMA: 16 °CAM: 20 °CMJ: 25 °CJJ: 26 °CJA: 25 °CAS: 22 °CSO: 16 °CON: 10 °CND: 6 °CD26 °C

Heating degree-days here run 31% below the median power plant in this dataset — a proxy for how much extra energy heated equipment must replace through its surfaces in winter.

Climate heat-demand index: 38/100 — this site sits in the mid third of the power plants we cover by heating degree-days.

A gas turbine here also runs ~0% below its ISO (15°C) rating at this annual mean (typical CCGT curve, estimate).

Climate normals: WorldClim 2.1 (1970–2000 monthly normals, 10 arc-min, CC BY 4.0); zone: Köppen-Geiger world climate classification (Kottek et al. 2006, 0.5° grid). Degree-days & heat-demand index computed by PowerAtlas — a modelled heat-demand proxy, not a measured site figure.

Site climate & environmental severity

This site sits in a benign, low-corrosion environment (estimated ISO 9223 class C1 — Very low), with dust abrasion the leading environmental stress.

C1ISO 9223 corrosivity (indicative)
40/100environmental-severity index
21.2°Cseasonal temperature swing
822 kmdistance to coast

Indicative estimate via the ISO 9223:2012 informative method (atmospheric corrosivity from temperature, time-of-wetness and airborne salinity), using WorldClim climate normals, the Köppen-Geiger class and coast distance. Indicative, not a measured corrosion rate.

How it compares & nearby plants

The #1413 largest gas power plant of 2165 in United States of America by capacity.

United States of America has 2165 gas power plants in this dataset, together about 789,950 MW of capacity.

Nearby power plants

Location

Coordinates 32.9781, -103.3239 from WRI Global Power Plant Database (CC BY 4.0). View on OpenStreetMap.

Frequently asked questions

What type of power plant is LCEC Generation LLVC?

LCEC Generation LLVC is a 46.5 MW gas power plant in New Mexico, United States of America, commissioned in 2012.

How much electricity does LCEC Generation LLVC generate?

LCEC Generation LLVC generates about 48 GWh of electricity per year.

Who operates LCEC Generation LLVC?

LCEC Generation LLVC is operated by Western Farmers Elec Coop Inc.

Built from open public data; no personal information. Operate this site? Request a correction or removal.