Hunlock Unit 4 — United States of America

Gas power plant in Pennsylvania, United States of America. Approximate location 41.2025, -76.0683.

GasPennsylvaniaUnited States of AmericaCO₂ modelled

Hunlock Unit 4 is a 44 MW gas power plant in Pennsylvania, United States of America. It is operated by Hunlock Energy LLC. Based on reported annual generation of 19 GWh, it can supply roughly 5.5k homes. It ranks #3850 of 10,884 United States of America power plants by installed capacity. Commissioned in 2001, it is around 25 years old — relatively modern. Its modelled annual emissions are 210,286 t CO₂/yr (Climate TRACE), equivalent to about 49k cars driven for a year. In context, gas supplies about 40.0% of United States of America's electricity; the national grid averages 384 gCO₂/kWh (43.0% low-carbon) (2025).

44MW installed capacity
19GWh reported / yr
5,542homes powered
210,286t CO₂ / yr (Climate TRACE)
2001commissioned (~25 yrs)

Plant data: WRI Global Power Plant Database (CC BY 4.0), id USA0056397.

Data status

Known data

FacilityHunlock Unit 4 WRI
CountryUnited States of America · Pennsylvania WRI
Coordinates41.2025, -76.0683 WRI
FuelGas WRI
MW installed capacity44 MW Wikidata P2109; installed/nameplate capacity
Verification noteQuality label backfilled from existing source-backed capacity provenance on 2026-07-05; capacity value was not changed. source-verified
OwnerHunlock Energy LLC WRI
Commissioned2001 WRI
GWh reported / yr19 GWh·a⁻¹ WRI

Modelled source data

CO₂ emissions210,286 t CO₂·a⁻¹ modelled · Climate TRACE

Calculated from dataset

Capacity rank in country#3850 / 10884 calculated
Fuel-specific rank in country#1431 / 2165 calculated
Capacity vs country/fuel peers0.36× · 121.2 MW · n=2165 calculated
Homes-powered equivalent5,542 calculated from reported generation
Climate8.3°C · HDD 3,663 derived from coordinates
Environmental severityC2 · 30/100 derived from coordinates

Not available

TechnologyNot available not in dataset

Known, modelled and calculated values are kept separate. Missing fields are shown as unavailable.

Capacity provenance

The public capacity above is the current source-record value. A 2026 tracker candidate lists 146 MW for Hunlock Power Station, but it is not used as the public primary value until scope is verified (unit vs operating vs installed/project total).

Data provenance

Source of the capacity and fuel values:

capacity: Wikidata P2109; fuel: WRI GPPD

In context: how this plant compares

At 44 MW, Hunlock Unit 4 is below the median gas plant in United States of America (121.2 MW). Gas plants burn natural gas either in open-cycle turbines for fast peaking, or in combined-cycle units that recover exhaust heat in an HRSG to reach roughly 55–62% efficiency — the cleanest-burning fossil option.

Capacity comparison computed from the WRI Global Power Plant Database; fuel-type context is general engineering background.

~210,286 t CO₂/yr (modelled) — in everyday terms

This facility's annual emissions are roughly equivalent to:

3.8kmillion cubic feet of natural gas burned
44khomes' electricity use for a year
210kacres of US forest absorbing CO₂ for a year
0.03%of the CO₂ from all United States of America power plants with an emissions figure in PowerAtlas

Equivalencies via US EPA Greenhouse Gas Equivalencies; modelled emissions from Climate TRACE.

Key facts

Load factor
5%, from 19 GWh of reported generation; the median for 1622 gas plants in United States of America that report generation is 26%
Generation trend
4 GWh in 2013 and 19 GWh in 2019 (+454%)
Highest and lowest year
2019: 19 GWh; 2015: 2 GWh
Share of United States of America gas capacity
less than 0.1% of 789,950 MW across 2,165 plants in this dataset
Age among peers
944 of 1,973 dated gas plants in United States of America are older

Calculated from the capacity and generation records in this dataset (WRI Global Power Plant Database (CC BY 4.0)).

Reported generation trend

2013: 4 GWh20132014: 6 GWh20142015: 2 GWh20152016: 3 GWh20162017: 3 GWh20172018: 6 GWh20182019: 19 GWh201919 GWh

Annual generation (GWh), WRI Global Power Plant Database (CC BY 4.0).

Owner

Operated by Hunlock Energy LLC.

Local climate & thermal context

This gas plant burns natural gas in a turbine — often in a combined-cycle setup — to generate electricity. It sits in a warm-summer humid continental climate (Köppen Dfb) — Northern Hemisphere, latitude 41.2°N — which shapes how much energy it can produce and how its output varies through the year.

8.3°Cannual mean temp
3,663heating degree-days (base 18°C)
134cooling degree-days (base 18°C)
437 melevation

Monthly mean temperature

J: -5 °CJF: -4 °CFM: 1 °CMA: 7 °CAM: 13 °CMJ: 18 °CJJ: 20 °CJA: 20 °CAS: 16 °CSO: 10 °CON: 4 °CND: -1 °CD20 °C

Heating degree-days here run 49% above the median power plant in this dataset — a proxy for how much extra energy heated equipment must replace through its surfaces in winter.

Climate heat-demand index: 79/100 — this site sits in the top third of the power plants we cover by heating degree-days.

A gas turbine here also runs ~0% below its ISO (15°C) rating at this annual mean (typical CCGT curve, estimate).

Climate normals: WorldClim 2.1 (1970–2000 monthly normals, 10 arc-min, CC BY 4.0); zone: Köppen-Geiger world climate classification (Kottek et al. 2006, 0.5° grid). Degree-days & heat-demand index computed by PowerAtlas — a modelled heat-demand proxy, not a measured site figure.

Site climate & environmental severity

This site sits in a mild atmospheric environment (estimated ISO 9223 class C2 — Low), with thermal cycling the leading environmental stress.

C2ISO 9223 corrosivity (indicative)
30/100environmental-severity index
25.3°Cseasonal temperature swing
200 kmdistance to coast

Indicative estimate via the ISO 9223:2012 informative method (atmospheric corrosivity from temperature, time-of-wetness and airborne salinity), using WorldClim climate normals, the Köppen-Geiger class and coast distance. Indicative, not a measured corrosion rate.

How it compares & nearby plants

The #1431 largest gas power plant of 2165 in United States of America by capacity.

United States of America has 2165 gas power plants in this dataset, together about 789,950 MW of capacity.

Nearby power plants

Location

Coordinates 41.2025, -76.0683 from WRI Global Power Plant Database (CC BY 4.0). View on OpenStreetMap.

Frequently asked questions

What type of power plant is Hunlock Unit 4?

Hunlock Unit 4 is a 44 MW gas power plant in Pennsylvania, United States of America, commissioned in 2001.

How much electricity does Hunlock Unit 4 generate?

Hunlock Unit 4 generates about 19 GWh of electricity per year.

Who operates Hunlock Unit 4?

Hunlock Unit 4 is operated by Hunlock Energy LLC.

How much CO₂ does Hunlock Unit 4 emit?

Hunlock Unit 4 has modelled emissions of about 210,286 tonnes of CO₂ per year (Climate TRACE).

Built from open public data; no personal information. Operate this site? Request a correction or removal.