Home / North America / United States of America / Greene Valley Gas Recovery

Greene Valley Gas Recovery

Waste power plant in Illinois, United States of America. Approximate location 41.7338, -88.0849.

WasteIllinoisUnited States of America

Greene Valley Gas Recovery is a 7 MW waste power plant in Illinois, United States of America. It is operated by WM Illinois Renewable Energy LLC. Based on reported annual generation of 35 GWh, it can supply roughly 10k homes. It ranks #6301 of 10,938 United States of America power plants by installed capacity. Commissioned in 1996, it is around 30 years old — long-established. In context, the national grid averages 384 gCO₂/kWh (43.0% low-carbon) (2025).

7Source-backed capacity
35GWh reported / yr
10,114homes powered
1996commissioned (~30 yrs)

Plant data: WRI Global Power Plant Database (CC BY 4.0), id USA0055014.

Data status

Known data

FacilityGreene Valley Gas Recovery WRI
CountryUnited States of America · Illinois WRI
Coordinates41.7338, -88.0849 WRI
FuelWaste WRI
MW installed capacity7 MW WRI source record; scope not independently normalised
OwnerWM Illinois Renewable Energy LLC WRI
Commissioned1996 WRI
GWh reported / yr35 GWh/yr WRI

Calculated from dataset

Capacity rank in country#6301 of 10938 calculated
Fuel-specific rank in country#278 of 551 calculated
Capacity vs country/fuel peers1.00× · 7 MW median · 551 peers calculated
Homes-powered equivalent10,114 calculated from reported generation
Climate10.0°C · HDD 3,326 derived from coordinates
Environmental severityC3 · 36/100 derived from coordinates

Not available

TechnologyNot available not in dataset
GWh reported / yrNot available not in dataset
CO₂ emissionsNot available not in dataset

Known, modelled and calculated values are kept separate. Missing fields are shown as unavailable.

Data provenance

The capacity and/or fuel fields on this page include a source-backed provenance label from GEM, an official registry, Wikidata, OSM, or a cross-source match.

capacity: Wikidata P2109 nameplate capacity; fuel: WRI source-record fuel

In context: how this plant compares

At 7 MW, Greene Valley Gas Recovery is around the median waste plant in United States of America (7 MW). Waste-to-energy plants burn municipal solid waste to generate electricity and heat, cutting landfill volume while recovering energy from residual waste.

Capacity comparison computed from the WRI Global Power Plant Database; fuel-type context is general engineering background.

Reported generation trend

2013: 42 GWh20132014: 43 GWh20142015: 40 GWh20152016: 40 GWh20162017: 38 GWh20172018: 36 GWh20182019: 35 GWh201943 GWh

Annual generation (GWh), WRI Global Power Plant Database (CC BY 4.0).

Owner

Operated by WM Illinois Renewable Energy LLC.

Local climate & thermal context

This waste plant recovers energy by combusting municipal or industrial waste. It sits in a hot-summer humid continental climate (Köppen Dfa) — Northern Hemisphere, latitude 41.7°N — which shapes how much energy it can produce and how its output varies through the year.

10.0°Cannual mean temp
3,326heating degree-days (base 18°C)
415cooling degree-days (base 18°C)
194 melevation

Monthly mean temperature

J: -6 °CJF: -3 °CFM: 3 °CMA: 10 °CAM: 16 °CMJ: 21 °CJJ: 24 °CJA: 22 °CAS: 18 °CSO: 12 °CON: 4 °CND: -2 °CD24 °C

Heating degree-days here run 35% above the median power plant in this dataset — a proxy for how much extra energy heated equipment must replace through its surfaces in winter.

Climate heat-demand index: 72/100 — this site sits in the top third of the power plants we cover by heating degree-days.

Climate normals: WorldClim 2.1 (1970–2000 monthly normals, 10 arc-min, CC BY 4.0); zone: Köppen-Geiger world climate classification (Kottek et al. 2006, 0.5° grid). Degree-days & heat-demand index computed by PowerAtlas — a modelled heat-demand proxy, not a measured site figure.

Site climate & environmental severity

For a plant’s outdoor hardware — heat-recovery steam generators (HRSG), expansion joints, valves, flanges and their insulation — the local climate sets how fast unprotected steel and coatings degrade. This site sits in a moderately corrosive environment (estimated ISO 9223 class C3 — Medium), with thermal cycling the leading environmental stress.

C3ISO 9223 corrosivity (indicative)
36/100environmental-severity index
29.3°Cseasonal temperature swing
59 kmdistance to coast

Higher environmental severity is exactly where protective removable insulation pays back most: a sheltered micro-climate slows corrosion, UV and thermal-cycling damage and extends outdoor hardware service life. This is an indicative site-climate context — not a condition assessment of any specific plant or operator.

Indicative estimate via the ISO 9223:2012 informative method (atmospheric corrosivity from temperature, time-of-wetness and airborne salinity), using WorldClim climate normals, the Köppen-Geiger class and coast distance. Indicative, not a measured corrosion rate.

How it compares & nearby plants

The #278 largest waste power plant of 551 in United States of America by capacity.

United States of America has 551 waste power plants in this dataset, together about 10,154 MW of capacity.

Nearby power plants

Location

Coordinates 41.7338, -88.0849 from WRI Global Power Plant Database (CC BY 4.0). View on OpenStreetMap.

Frequently asked questions

What type of power plant is Greene Valley Gas Recovery?

Greene Valley Gas Recovery is a 7 MW source-record waste power plant in Illinois, United States of America, commissioned in 1996.

How much electricity does Greene Valley Gas Recovery generate?

Greene Valley Gas Recovery generates about 35 GWh of electricity per year.

How many homes can Greene Valley Gas Recovery power?

Its output is enough to supply roughly 10,114 homes.

Who operates Greene Valley Gas Recovery?

Greene Valley Gas Recovery is operated by WM Illinois Renewable Energy LLC.

Built from open public data; no personal information. Operate this site? Request a correction or removal.