Glen Gardner

Gas power plant in New Jersey, United States of America. Approximate location 40.6815, -74.9207.

GasNew JerseyUnited States of AmericaRetired

Glen Gardner is a 160 MW gas power station in New Jersey, United States of America. Based on its capacity (estimated), it can supply roughly 180k homes (estimated). It ranks #2265 of 10,938 United States of America power plants by installed capacity. In context, gas supplies about 40.0% of United States of America's electricity; the national grid averages 384 gCO₂/kWh (43.0% low-carbon) (2025).

160Source-backed capacity
179,755homes powered (est.)

Plant data: WRI Global Power Plant Database (CC BY 4.0), id CT-1819.

Data status

Known data

FacilityGlen Gardner Climate TRACE
CountryUnited States of America · New Jersey Climate TRACE
Coordinates40.6815, -74.9207 Climate TRACE
FuelGas Climate TRACE
MW installed capacity160 MW Climate TRACE source record; scope not independently normalised

Calculated from dataset

CO₂ emissions251,657 t CO₂/yr calculated
Capacity rank in country#2265 of 10938 calculated
Fuel-specific rank in country#991 of 2165 calculated
Capacity vs country/fuel peers1.32× · 121 MW median · 2165 peers calculated
Homes-powered equivalent179,755 calculated
Climate10.8°C · HDD 2,978 derived from coordinates
Environmental severityC3 · 37/100 derived from coordinates

Not available

OwnerNot available not in dataset
CommissionedNot available not in dataset
TechnologyNot available not in dataset
GWh reported / yrNot available not in dataset

Known, modelled and calculated values are kept separate. Missing fields are shown as unavailable.

Data provenance

The capacity and/or fuel fields on this page include a source-backed provenance label from GEM, an official registry, Wikidata, OSM, or a cross-source match.

capacity: EIA-860M May 2026 retired generator inventory, summed by Plant ID; fuel: Climate TRACE source-record fuel

In context: how this plant compares

At 160 MW, Glen Gardner is well above the median gas plant in United States of America (121 MW). Its current lifecycle status is “retired” — so it is not yet, or no longer, generating at full output. Gas plants burn natural gas either in open-cycle turbines for fast peaking, or in combined-cycle units that recover exhaust heat in an HRSG to reach roughly 55–62% efficiency — the cleanest-burning fossil option.

Capacity comparison computed from the WRI Global Power Plant Database; fuel-type context is general engineering background.

Capacity vs largest gas plants in United States of America

Fermi America Project Matador power station: 6,000 MW6kFermi Amer…Chevron AI Data Center Project: 5,000 MW5kChevron AI…GW Ranch Energy Center: 5,000 MW5kGW Ranch E…West County Energy Center: 4,263 MW4kWest Count…Pittsylvania power station: 3,800 MW4kPittsylvan…Bruce Mansfield power station: 3,641 MW4kBruce Mans…Crystal River: 3,449 MW3kCrystal Ri…Schahfer Generating Station: 2,958 MW3kSchahfer G…

Installed capacity (MW), WRI Global Power Plant Database (CC BY 4.0).

Local climate & thermal context

This gas plant burns natural gas in a turbine — often in a combined-cycle setup — to generate electricity. It sits in a humid subtropical climate (Köppen Cfa) — Northern Hemisphere, latitude 40.7°N — which shapes how much energy it can produce and how its output varies through the year.

10.8°Cannual mean temp
2,978heating degree-days (base 18°C)
359cooling degree-days (base 18°C)
58 melevation

Monthly mean temperature

J: -2 °CJF: -1 °CFM: 4 °CMA: 10 °CAM: 15 °CMJ: 20 °CJJ: 23 °CJA: 22 °CAS: 18 °CSO: 12 °CON: 6 °CND: 1 °CD23 °C

Heating degree-days here run 21% above the median power plant in this dataset — a proxy for how much extra energy heated equipment must replace through its surfaces in winter.

Climate heat-demand index: 62/100 — this site sits in the mid third of the power plants we cover by heating degree-days.

A gas turbine here also runs ~0% below its ISO (15°C) rating at this annual mean (typical CCGT curve, estimate).

Climate normals: WorldClim 2.1 (1970–2000 monthly normals, 10 arc-min, CC BY 4.0); zone: Köppen-Geiger world climate classification (Kottek et al. 2006, 0.5° grid). Degree-days & heat-demand index computed by PowerAtlas — a modelled heat-demand proxy, not a measured site figure.

Site climate & environmental severity

For a plant’s outdoor hardware — heat-recovery steam generators (HRSG), expansion joints, valves, flanges and their insulation — the local climate sets how fast unprotected steel and coatings degrade. This site sits in a moderately corrosive environment (estimated ISO 9223 class C3 — Medium), with humidity / wetness the leading environmental stress.

C3ISO 9223 corrosivity (indicative)
37/100environmental-severity index
25.2°Cseasonal temperature swing
130 kmdistance to coast

Higher environmental severity is exactly where protective removable insulation pays back most: a sheltered micro-climate slows corrosion, UV and thermal-cycling damage and extends outdoor hardware service life. This is an indicative site-climate context — not a condition assessment of any specific plant or operator.

Indicative estimate via the ISO 9223:2012 informative method (atmospheric corrosivity from temperature, time-of-wetness and airborne salinity), using WorldClim climate normals, the Köppen-Geiger class and coast distance. Indicative, not a measured corrosion rate.

How it compares & nearby plants

The #991 largest gas power plant of 2165 in United States of America by capacity.

United States of America has 2165 gas power plants in this dataset, together about 789,950 MW of capacity.

Nearby power plants

Location

Coordinates 40.6815, -74.9207 from WRI Global Power Plant Database (CC BY 4.0). View on OpenStreetMap.

Frequently asked questions

What type of power plant is Glen Gardner?

Glen Gardner is a 160 MW source-record gas power plant in New Jersey, United States of America.

How many homes can Glen Gardner power?

Its output is enough to supply roughly 179,755 homes (estimated).

Built from open public data; no personal information. Operate this site? Request a correction or removal.