Home / Europe / France / ENERSOL TIOXIDE

ENERSOL TIOXIDE — France

Gas power plant in Nord-Pas-de-Calais, France. Approximate location 50.967, 1.878.

GasNord-Pas-de-CalaisFranceCO₂ modelled

ENERSOL TIOXIDE is a 55 MW gas power plant in Nord-Pas-de-Calais, France. Based on its capacity (estimated), it can supply roughly 62k homes (estimated). It ranks #164 of 2,216 France power plants by installed capacity. Its modelled annual emissions are 31,176 t CO₂/yr (Climate TRACE), equivalent to about 7.3k cars driven for a year. In context, gas supplies about 3.0% of France's electricity; the national grid averages 41 gCO₂/kWh (94.9% low-carbon) (2025).

55MW installed capacity
61,945homes powered (est.)
31,176t CO₂ / yr (Climate TRACE)

Plant data: WRI Global Power Plant Database (CC BY 4.0), id CT-170.

Data status

Known data

FacilityENERSOL TIOXIDE Climate TRACE
CountryFrance · Nord-Pas-de-Calais Climate TRACE
Coordinates50.967, 1.878 Climate TRACE
FuelGas Climate TRACE
MW installed capacity55 MW Climate TRACE; source record

Modelled source data

CO₂ emissions31,176 t CO₂·a⁻¹ modelled · Climate TRACE

Calculated from dataset

Capacity rank in country#164 / 2216 calculated
Fuel-specific rank in country#21 / 34 calculated
Capacity vs country/fuel peers0.63× · 87.2 MW · n=34 calculated
Homes-powered equivalent61,945 calculated
Climate10.6°C · HDD 2,681 derived from coordinates
Environmental severityC4 · 32/100 derived from coordinates

Not available

OwnerNot available not in dataset
CommissionedNot available not in dataset
TechnologyNot available not in dataset
GWh reported / yrNot available not in dataset

Known, modelled and calculated values are kept separate. Missing fields are shown as unavailable.

Data provenance

Capacity and fuel are the upstream open-dataset record, not yet matched to a 2026 registry or GEM entry.

capacity: Climate TRACE; fuel: Climate TRACE

In context: how this plant compares

At 55 MW, ENERSOL TIOXIDE is below the median gas plant in France (87.2 MW). Gas plants burn natural gas either in open-cycle turbines for fast peaking, or in combined-cycle units that recover exhaust heat in an HRSG to reach roughly 55–62% efficiency — the cleanest-burning fossil option.

Capacity comparison computed from the WRI Global Power Plant Database; fuel-type context is general engineering background.

~31,176 t CO₂/yr (modelled) — in everyday terms

This facility's annual emissions are roughly equivalent to:

569million cubic feet of natural gas burned
6.5khomes' electricity use for a year
520ktree seedlings grown for 10 years
0.29%of the CO₂ from all France power plants with an emissions figure in PowerAtlas

Equivalencies via US EPA Greenhouse Gas Equivalencies; modelled emissions from Climate TRACE.

Key facts

Share of France gas capacity
0.7% of 7,707 MW across 34 plants in this dataset

Calculated from the capacity and generation records in this dataset (WRI Global Power Plant Database (CC BY 4.0)).

Capacity vs largest gas plants in France

MARTIGUES PONTEAU: 998 MW998MARTIGUES …EMILE HUCHET: 826 MW826EMILE HUCH…DK6: 808 MW808DK6BOUCHAIN 7: 575 MW575BOUCHAIN 7COMBIGOLFE: 453 MW453COMBIGOLFEPont-sur-Sambre: 450 MW450Pont-sur-S…Landivisiau power station: 446 MW446Landivisia…BLENOD 5: 427 MW427BLENOD 5

Installed capacity (MW), WRI Global Power Plant Database (CC BY 4.0).

Local climate & thermal context

This gas plant burns natural gas in a turbine — often in a combined-cycle setup — to generate electricity. It sits in a temperate oceanic climate (Köppen Cfb) — Northern Hemisphere, latitude 51.0°N — which shapes how much energy it can produce and how its output varies through the year.

10.6°Cannual mean temp
2,681heating degree-days (base 18°C)
0cooling degree-days (base 18°C)
9 melevation

Monthly mean temperature

J: 4 °CJF: 4 °CFM: 7 °CMA: 9 °CAM: 12 °CMJ: 15 °CJJ: 17 °CJA: 18 °CAS: 15 °CSO: 12 °CON: 8 °CND: 6 °CD18 °C

Heating degree-days here run 9% above the median power plant in this dataset — a proxy for how much extra energy heated equipment must replace through its surfaces in winter.

Climate heat-demand index: 54/100 — this site sits in the mid third of the power plants we cover by heating degree-days.

A gas turbine here also runs ~0% below its ISO (15°C) rating at this annual mean (typical CCGT curve, estimate).

Climate normals: WorldClim 2.1 (1970–2000 monthly normals, 10 arc-min, CC BY 4.0); zone: Köppen-Geiger world climate classification (Kottek et al. 2006, 0.5° grid). Degree-days & heat-demand index computed by PowerAtlas — a modelled heat-demand proxy, not a measured site figure.

Site climate & environmental severity

This site sits in a corrosive environment (estimated ISO 9223 class C4 — High), with humidity / wetness the leading environmental stress.

C4ISO 9223 corrosivity (indicative)
32/100environmental-severity index
13.1°Cseasonal temperature swing
23 kmdistance to coast

Indicative estimate via the ISO 9223:2012 informative method (atmospheric corrosivity from temperature, time-of-wetness and airborne salinity), using WorldClim climate normals, the Köppen-Geiger class and coast distance. Indicative, not a measured corrosion rate.

How it compares & nearby plants

The #21 largest gas power plant of 34 in France by capacity.

France has 34 gas power plants in this dataset, together about 7,707 MW of capacity.

Nearby power plants

  • Calais · Biomass · 0.95 MW · Nord-Pas-de-Calais
  • Coquelles · Wind · 2.4 MW · Nord-Pas-de-Calais
  • Fiennes · Wind · 12 MW · Nord-Pas-de-Calais
  • GRAVELINES · Nuclear · 5,706 MW · Nord-Pas-de-Calais
  • Sainte-Marie-Kerque · Biomass · 1.5 MW · Nord-Pas-de-Calais
  • Loon-Plage · Wind · 12 MW · Nord-Pas-de-Calais

Location

Coordinates 50.967, 1.878 from WRI Global Power Plant Database (CC BY 4.0). View on OpenStreetMap.

Frequently asked questions

What type of power plant is ENERSOL TIOXIDE?

ENERSOL TIOXIDE is a 55 MW gas power plant in Nord-Pas-de-Calais, France.

How much CO₂ does ENERSOL TIOXIDE emit?

ENERSOL TIOXIDE has modelled emissions of about 31,176 tonnes of CO₂ per year (Climate TRACE).

Built from open public data; no personal information. Operate this site? Request a correction or removal.