Dry Fork Station — United States of America

Coal power plant in Wyoming, United States of America. Approximate location 44.3889, -105.4608.

CoalWyomingUnited States of America

Dry Fork Station is a 483.7 MW coal power station in Wyoming, United States of America. It is operated by Basin Electric Power Coop. Based on reported annual generation of 2,566 GWh, it can supply roughly 733k homes. It ranks #1258 of 10,884 United States of America power plants by installed capacity. Commissioned in 2011, it is around 15 years old — relatively modern. In context, coal supplies about 16.3% of United States of America's electricity; the national grid averages 384 gCO₂/kWh (43.0% low-carbon) (2025).

483.7MW installed capacity
2,566GWh reported / yr
733,000homes powered
2011commissioned (~15 yrs)

Plant data: WRI Global Power Plant Database (CC BY 4.0), id USA0056609.

Data status

Known data

FacilityDry Fork Station WRI
CountryUnited States of America · Wyoming WRI
Coordinates44.3889, -105.4608 WRI
FuelCoal WRI
MW installed capacity483.7 MW GEM · 2026 · L100000104282; operating plant capacity
Verification noteQuality label backfilled from existing source-backed capacity provenance on 2026-07-05; capacity value was not changed. source-verified
OwnerBasin Electric Power Coop WRI
Commissioned2011 WRI
GWh reported / yr2,566 GWh·a⁻¹ WRI

Calculated from dataset

CO₂ emissions2,565,500 t CO₂·a⁻¹ calculated
Capacity rank in country#1258 / 10884 calculated
Fuel-specific rank in country#428 / 802 calculated
Capacity vs country/fuel peers0.87× · 558 MW · n=802 calculated
Homes-powered equivalent733,000 calculated from reported generation
Climate6.9°C · HDD 4,185 derived from coordinates
Environmental severityC1 · 38/100 derived from coordinates

Not available

TechnologyNot available not in dataset

Known, modelled and calculated values are kept separate. Missing fields are shown as unavailable.

Data provenance

Source of the capacity and fuel values:

capacity: GEM · 2026 · L100000104282; fuel: WRI GPPD

In context: how this plant compares

At 483.7 MW, Dry Fork Station is below the median coal plant in United States of America (558 MW). Coal plants burn pulverised coal to raise high-pressure steam for a turbine; they run as baseload but are the most carbon-intensive mainstream source and the first targeted for retirement or efficiency retrofits.

Capacity comparison computed from the WRI Global Power Plant Database; fuel-type context is general engineering background.

Key facts

Load factor
61%, from 2,566 GWh of reported generation; the median for 244 coal plants in United States of America that report generation is 41%
Generation trend
3,067 GWh in 2013 and 2,566 GWh in 2019 (−16%)
Highest and lowest year
2014: 3,277 GWh; 2019: 2,566 GWh
Share of United States of America coal capacity
less than 0.1% of 621,194 MW across 802 plants in this dataset
Age among peers
721 of 745 dated coal plants in United States of America are older

Calculated from the capacity and generation records in this dataset (WRI Global Power Plant Database (CC BY 4.0)).

Reported generation trend

2013: 3,067 GWh20132014: 3,277 GWh20142015: 3,161 GWh20152016: 2,831 GWh20162017: 3,230 GWh20172018: 2,980 GWh20182019: 2,566 GWh20193k GWh

Annual generation (GWh), WRI Global Power Plant Database (CC BY 4.0).

Local climate & thermal context

This coal plant burns coal to raise high-pressure steam that spins a turbine-generator. It sits in a cold semi-arid steppe climate (Köppen BSk) — Northern Hemisphere, latitude 44.4°N — which shapes how much energy it can produce and how its output varies through the year.

6.9°Cannual mean temp
4,185heating degree-days (base 18°C)
167cooling degree-days (base 18°C)
1,396 melevation

Monthly mean temperature

J: -6 °CJF: -3 °CFM: 1 °CMA: 6 °CAM: 11 °CMJ: 17 °CJJ: 21 °CJA: 20 °CAS: 14 °CSO: 8 °CON: 0 °CND: -5 °CD21 °C

Heating degree-days here run 70% above the median power plant in this dataset — a proxy for how much extra energy heated equipment must replace through its surfaces in winter.

Climate heat-demand index: 86/100 — this site sits in the top third of the power plants we cover by heating degree-days.

Climate normals: WorldClim 2.1 (1970–2000 monthly normals, 10 arc-min, CC BY 4.0); zone: Köppen-Geiger world climate classification (Kottek et al. 2006, 0.5° grid). Degree-days & heat-demand index computed by PowerAtlas — a modelled heat-demand proxy, not a measured site figure.

Site climate & environmental severity

This site sits in a benign, low-corrosion environment (estimated ISO 9223 class C1 — Very low), with dust abrasion the leading environmental stress.

C1ISO 9223 corrosivity (indicative)
38/100environmental-severity index
27.3°Cseasonal temperature swing
1022 kmdistance to coast

Indicative estimate via the ISO 9223:2012 informative method (atmospheric corrosivity from temperature, time-of-wetness and airborne salinity), using WorldClim climate normals, the Köppen-Geiger class and coast distance. Indicative, not a measured corrosion rate.

How it compares & nearby plants

The #428 largest coal power plant of 802 in United States of America by capacity.

United States of America has 802 coal power plants in this dataset, together about 621,194 MW of capacity.

Nearby power plants

Location

Coordinates 44.3889, -105.4608 from WRI Global Power Plant Database (CC BY 4.0). View on OpenStreetMap.

Frequently asked questions

What type of power plant is Dry Fork Station?

Dry Fork Station is a 483.7 MW coal power plant in Wyoming, United States of America, commissioned in 2011.

How much electricity does Dry Fork Station generate?

Dry Fork Station generates about 2,566 GWh of electricity per year.

Who operates Dry Fork Station?

Dry Fork Station is operated by Basin Electric Power Coop.

Built from open public data; no personal information. Operate this site? Request a correction or removal.