Home / Europe / Germany / Dormagen

Dormagen

Gas power plant in North Rhine-Westphalia, Germany. Approximate location 51.0791, 6.8287.

GasNorth Rhine-WestphaliaGermanyCCGT · HRSG

Dormagen is a 586 MW gas power station in North Rhine-Westphalia, Germany. It is operated by RWE Generation SE. Based on reported annual generation of 948 GWh, it can supply roughly 271k homes. It ranks #80 of 1,442 Germany power plants by installed capacity. Commissioned in 2000, it is around 26 years old — long-established. In context, gas supplies about 16.5% of Germany's electricity; the national grid averages 330 gCO₂/kWh (59.1% low-carbon) (2025).

586Source-backed capacity
1HRSG unit(s)
948GWh reported / yr
270,885homes powered
2000commissioned (~26 yrs)

Plant data: WRI Global Power Plant Database (CC BY 4.0), id WRI1005636.

Data status

Known data

FacilityDormagen WRI
CountryGermany · North Rhine-Westphalia WRI
Coordinates51.0791, 6.8287 WRI
FuelGas WRI
MW installed capacity586 MW WRI source record; scope not independently normalised
OwnerRWE Generation SE WRI
Commissioned2000 WRI
TechnologyCCGT · HRSG WRI
GWh reported / yr948 GWh/yr WRI

Calculated from dataset

CO₂ emissions379,240 t CO₂/yr calculated
Capacity rank in country#80 of 1442 calculated
Fuel-specific rank in country#16 of 241 calculated
Capacity vs country/fuel peers11.08× · 53 MW median · 241 peers calculated
Homes-powered equivalent270,885 calculated from reported generation
Climate10.7°C · HDD 2,705 derived from coordinates
Environmental severityC2 · 25/100 derived from coordinates

Not available

GWh reported / yrNot available not in dataset

Known, modelled and calculated values are kept separate. Missing fields are shown as unavailable.

Data provenance

The capacity and/or fuel fields on this page include a source-backed provenance label from GEM, an official registry, Wikidata, OSM, or a cross-source match.

capacity: GEM tracker 2026 (location L100000400134); fuel: WRI source-record fuel

In context: how this plant compares

At 586 MW, Dormagen is well above the median gas plant in Germany (53 MW). Technically it is described as CCGT; combined-cycle with a heat-recovery steam generator (HRSG). Gas plants burn natural gas either in open-cycle turbines for fast peaking, or in combined-cycle units that recover exhaust heat in an HRSG to reach roughly 55–62% efficiency — the cleanest-burning fossil option.

Capacity comparison computed from the WRI Global Power Plant Database; fuel-type context is general engineering background.

Reported generation trend

2015: 2,193 GWh20152016: 1,413 GWh20162017: 948 GWh20172k GWh

Annual generation (GWh), WRI Global Power Plant Database (CC BY 4.0).

Owner

Operated by RWE Generation SE. All plants by this company →

Local climate & thermal context

This gas plant burns natural gas in a turbine — often in a combined-cycle setup — to generate electricity. It sits in a temperate oceanic climate (Köppen Cfb) — Northern Hemisphere, latitude 51.1°N — which shapes how much energy it can produce and how its output varies through the year.

10.7°Cannual mean temp
2,705heating degree-days (base 18°C)
46cooling degree-days (base 18°C)
59 melevation

Monthly mean temperature

J: 3 °CJF: 4 °CFM: 7 °CMA: 10 °CAM: 14 °CMJ: 17 °CJJ: 19 °CJA: 19 °CAS: 15 °CSO: 11 °CON: 6 °CND: 4 °CD19 °C

Heating degree-days here run 10% above the median power plant in this dataset — a proxy for how much extra energy heated equipment must replace through its surfaces in winter.

Climate heat-demand index: 55/100 — this site sits in the mid third of the power plants we cover by heating degree-days.

A gas turbine here also runs ~0% below its ISO (15°C) rating at this annual mean (typical CCGT curve, estimate).

Climate normals: WorldClim 2.1 (1970–2000 monthly normals, 10 arc-min, CC BY 4.0); zone: Köppen-Geiger world climate classification (Kottek et al. 2006, 0.5° grid). Degree-days & heat-demand index computed by PowerAtlas — a modelled heat-demand proxy, not a measured site figure.

Site climate & environmental severity

For a plant’s outdoor hardware — heat-recovery steam generators (HRSG), expansion joints, valves, flanges and their insulation — the local climate sets how fast unprotected steel and coatings degrade. This site sits in a mild atmospheric environment (estimated ISO 9223 class C2 — Low), with humidity / wetness the leading environmental stress.

C2ISO 9223 corrosivity (indicative)
25/100environmental-severity index
15.8°Cseasonal temperature swing
163 kmdistance to coast

Higher environmental severity is exactly where protective removable insulation pays back most: a sheltered micro-climate slows corrosion, UV and thermal-cycling damage and extends outdoor hardware service life. This is an indicative site-climate context — not a condition assessment of any specific plant or operator.

Indicative estimate via the ISO 9223:2012 informative method (atmospheric corrosivity from temperature, time-of-wetness and airborne salinity), using WorldClim climate normals, the Köppen-Geiger class and coast distance. Indicative, not a measured corrosion rate.

How it compares & nearby plants

The #16 largest gas power plant of 241 in Germany by capacity.

Germany has 241 gas power plants in this dataset, together about 37,245 MW of capacity.

Nearby power plants

Location

Coordinates 51.0791, 6.8287 from WRI Global Power Plant Database (CC BY 4.0). View on OpenStreetMap.

Frequently asked questions

What type of power plant is Dormagen?

Dormagen is a 586 MW source-record gas power plant in North Rhine-Westphalia, Germany, commissioned in 2000.

How much electricity does Dormagen generate?

Dormagen generates about 948 GWh of electricity per year.

How many homes can Dormagen power?

Its output is enough to supply roughly 270,885 homes.

Who operates Dormagen?

Dormagen is operated by RWE Generation SE.

Built from open public data; no personal information. Operate this site? Request a correction or removal.