Coal power plant in Colorado, United States of America. Approximate location 38.2081, -104.5747.

CoalColoradoUnited States of AmericaCO₂ measured

Comanche (CO) is a 1,635 MW coal power station in Colorado, United States of America. It is operated by Public Service Co of Colorado. Based on reported annual generation of 8,500 GWh, it can supply roughly 2.4 million homes. It ranks #333 of 10,938 United States of America power plants by installed capacity. Commissioned in 1992, it is around 34 years old — long-established. Its annual emissions of 6,991,406 t CO₂/yr (US EPA GHGRP) are equivalent to about 1.6 million cars driven for a year. In context, coal supplies about 16.3% of United States of America's electricity; the national grid averages 384 gCO₂/kWh (43.0% low-carbon) (2025).

1,635Source-backed capacity
8,500GWh reported / yr
2,428,542homes powered
6,991,406t CO₂ / yr (US EPA GHGRP)
1992commissioned (~34 yrs)

Plant data: WRI Global Power Plant Database (CC BY 4.0), id USA0000470.

Data status

Known data

FacilityComanche (CO) WRI
CountryUnited States of America · Colorado WRI
Coordinates38.2081, -104.5747 WRI
FuelCoal WRI
MW installed capacity1,635 MW WRI source record; scope not independently normalised
OwnerPublic Service Co of Colorado WRI
Commissioned1992 WRI
GWh reported / yr8,500 GWh/yr WRI
CO₂ emissions6,991,406 t CO₂/yr measured · US EPA GHGRP

Calculated from dataset

Capacity rank in country#333 of 10938 calculated
Fuel-specific rank in country#117 of 802 calculated
Capacity vs country/fuel peers2.93× · 558 MW median · 802 peers calculated
Homes-powered equivalent2,428,542 calculated from reported generation
Climate11.6°C · HDD 2,831 derived from coordinates
Environmental severityC1 · 39/100 derived from coordinates

Not available

TechnologyNot available not in dataset
GWh reported / yrNot available not in dataset

Known, modelled and calculated values are kept separate. Missing fields are shown as unavailable.

Capacity provenance

The public capacity above is the current source-record value. A 2026 tracker candidate lists 1,253 MW for Comanche power station, but it is not used as the public primary value until scope is verified (unit vs operating vs installed/project total).

Capacity claim grade: B_SCOPE_PARENT_COMPLEX - recommended action: build_parent_complex_model - confidence: not_comparable_without_scope. This follows a claim-based data model: value + scope + source + confidence, rather than silently overwriting records.

Data provenance

The capacity and/or fuel fields on this page include a source-backed provenance label from GEM, an official registry, Wikidata, OSM, or a cross-source match.

capacity: GEM tracker 2026 (location L100000103807); fuel: WRI source-record fuel

In context: how this plant compares

At 1,635 MW, Comanche (CO) is well above the median coal plant in United States of America (558 MW). Coal plants burn pulverised coal to raise high-pressure steam for a turbine; they run as baseload but are the most carbon-intensive mainstream source and the first targeted for retirement or efficiency retrofits.

Capacity comparison computed from the WRI Global Power Plant Database; fuel-type context is general engineering background.

6,991,406 t CO₂/yr — in everyday terms

This facility's annual emissions are roughly equivalent to:

1.6 millionpassenger cars driven for a year
912khomes' yearly energy use
117 milliontree seedlings grown 10 years to absorb it

Equivalencies via US EPA Greenhouse Gas Equivalencies; emissions per US EPA GHGRP (measured for US EPA/EU ETS, modelled for Climate TRACE).

Reported generation trend

2013: 8,960 GWh20132014: 8,290 GWh20142015: 8,636 GWh20152016: 9,060 GWh20162017: 9,275 GWh20172018: 9,762 GWh20182019: 8,500 GWh201910k GWh

Annual generation (GWh), WRI Global Power Plant Database (CC BY 4.0).

Owner

Operated by Public Service Co of Colorado. All plants by this company →

Local climate & thermal context

This coal plant burns coal to raise high-pressure steam that spins a turbine-generator. It sits in a cold semi-arid steppe climate (Köppen BSk) — Northern Hemisphere, latitude 38.2°N — which shapes how much energy it can produce and how its output varies through the year.

11.6°Cannual mean temp
2,831heating degree-days (base 18°C)
532cooling degree-days (base 18°C)
1,480 melevation

Monthly mean temperature

J: -1 °CJF: 2 °CFM: 6 °CMA: 11 °CAM: 16 °CMJ: 22 °CJJ: 25 °CJA: 24 °CAS: 19 °CSO: 12 °CON: 4 °CND: 0 °CD25 °C

Heating degree-days here run 15% above the median power plant in this dataset — a proxy for how much extra energy heated equipment must replace through its surfaces in winter.

Climate heat-demand index: 58/100 — this site sits in the mid third of the power plants we cover by heating degree-days.

Climate normals: WorldClim 2.1 (1970–2000 monthly normals, 10 arc-min, CC BY 4.0); zone: Köppen-Geiger world climate classification (Kottek et al. 2006, 0.5° grid). Degree-days & heat-demand index computed by PowerAtlas — a modelled heat-demand proxy, not a measured site figure.

Site climate & environmental severity

For a plant’s outdoor hardware — heat-recovery steam generators (HRSG), expansion joints, valves, flanges and their insulation — the local climate sets how fast unprotected steel and coatings degrade. This site sits in a benign, low-corrosion environment (estimated ISO 9223 class C1 — Very low), with dust abrasion the leading environmental stress.

C1ISO 9223 corrosivity (indicative)
39/100environmental-severity index
25.7°Cseasonal temperature swing
1133 kmdistance to coast

Higher environmental severity is exactly where protective removable insulation pays back most: a sheltered micro-climate slows corrosion, UV and thermal-cycling damage and extends outdoor hardware service life. This is an indicative site-climate context — not a condition assessment of any specific plant or operator.

Indicative estimate via the ISO 9223:2012 informative method (atmospheric corrosivity from temperature, time-of-wetness and airborne salinity), using WorldClim climate normals, the Köppen-Geiger class and coast distance. Indicative, not a measured corrosion rate.

How it compares & nearby plants

The #117 largest coal power plant of 802 in United States of America by capacity.

United States of America has 802 coal power plants in this dataset, together about 621,194 MW of capacity.

Nearby power plants

Location

Coordinates 38.2081, -104.5747 from WRI Global Power Plant Database (CC BY 4.0). View on OpenStreetMap.

Frequently asked questions

What type of power plant is Comanche (CO)?

Comanche (CO) is a 1,635 MW source-record coal power plant in Colorado, United States of America, commissioned in 1992.

How much electricity does Comanche (CO) generate?

Comanche (CO) generates about 8,500 GWh of electricity per year.

How many homes can Comanche (CO) power?

Its output is enough to supply roughly 2,428,542 homes.

Who operates Comanche (CO)?

Comanche (CO) is operated by Public Service Co of Colorado.

How much CO₂ does Comanche (CO) emit?

Comanche (CO) has measured emissions of about 6,991,406 tonnes of CO₂ per year (US EPA GHGRP).