Gas power plant in Massachusetts, United States of America. Approximate location 41.8653, -71.1061.

GasMassachusettsUnited States of AmericaCCGT · HRSGCO₂ measured

Cleary Flood Hybrid is a 146.3 MW gas power station in Massachusetts, United States of America. It is operated by City of Taunton. Based on reported annual generation of 34 GWh, it can supply roughly 9.6k homes. It ranks #2334 of 10,884 United States of America power plants by installed capacity. Commissioned in 1974, it is around 52 years old — an older, legacy facility. Its annual emissions of 31,764 t CO₂/yr (US EPA GHGRP) are equivalent to about 7.4k cars driven for a year. In context, gas supplies about 40.0% of United States of America's electricity; the national grid averages 384 gCO₂/kWh (43.0% low-carbon) (2025).

146.3MW installed capacity
1HRSG unit(s)
34GWh reported / yr
9,600homes powered
31,764t CO₂ / yr (US EPA GHGRP)
1974commissioned (~52 yrs)

Plant data: WRI Global Power Plant Database (CC BY 4.0), id USA0001682.

Data status

Known data

FacilityCleary Flood Hybrid WRI
CountryUnited States of America · Massachusetts WRI
Coordinates41.8653, -71.1061 WRI
FuelGas WRI
MW installed capacity146.3 MW GEM · 2026 · L100000401542; part of a generating complex
Verification noteQuality label backfilled from existing source-backed capacity provenance on 2026-07-05; capacity value was not changed. source-verified
OwnerCity of Taunton WRI
Commissioned1974 WRI
TechnologyCCGT · HRSG WRI
GWh reported / yr34 GWh·a⁻¹ WRI
CO₂ emissions31,764 t CO₂·a⁻¹ measured · US EPA GHGRP

Calculated from dataset

Capacity rank in country#2334 / 10884 calculated
Fuel-specific rank in country#1016 / 2165 calculated
Capacity vs country/fuel peers1.21× · 121.2 MW · n=2165 calculated
Homes-powered equivalent9,600 calculated from reported generation
Climate9.9°C · HDD 3,177 derived from coordinates
Environmental severityC3 · 35/100 derived from coordinates

Known, modelled and calculated values are kept separate. Missing fields are shown as unavailable.

Capacity provenance

The public capacity above is the current source-record value. A 2026 tracker candidate lists 118 MW for Cleary Flood power station, but it is not used as the public primary value until scope is verified (unit vs operating vs installed/project total).

Data provenance

Source of the capacity and fuel values:

capacity: GEM · 2026 · L100000401542; fuel: WRI GPPD

In context: how this plant compares

At 146.3 MW, Cleary Flood Hybrid is well above the median gas plant in United States of America (121.2 MW). Technically it is described as CCGT; combined-cycle with a heat-recovery steam generator (HRSG). Gas plants burn natural gas either in open-cycle turbines for fast peaking, or in combined-cycle units that recover exhaust heat in an HRSG to reach roughly 55–62% efficiency — the cleanest-burning fossil option.

Capacity comparison computed from the WRI Global Power Plant Database; fuel-type context is general engineering background.

31,764 t CO₂/yr — in everyday terms

This facility's annual emissions are roughly equivalent to:

580million cubic feet of natural gas burned
6.6khomes' electricity use for a year
529ktree seedlings grown for 10 years

Equivalencies via US EPA Greenhouse Gas Equivalencies; emissions per US EPA GHGRP (measured for US EPA/EU ETS, modelled for Climate TRACE).

Key facts

Load factor
3%, from 34 GWh of reported generation; the median for 1622 gas plants in United States of America that report generation is 26%
Generation trend
80 GWh in 2013 and 34 GWh in 2019 (−58%)
Highest and lowest year
2015: 168 GWh; 2019: 34 GWh
Share of United States of America gas capacity
less than 0.1% of 789,950 MW across 2,165 plants in this dataset
Age among peers
236 of 1,973 dated gas plants in United States of America are older

Calculated from the capacity and generation records in this dataset (WRI Global Power Plant Database (CC BY 4.0)).

Reported generation trend

2013: 80 GWh20132014: 140 GWh20142015: 168 GWh20152016: 78 GWh20162017: 58 GWh20172018: 77 GWh20182019: 34 GWh2019168 GWh

Annual generation (GWh), WRI Global Power Plant Database (CC BY 4.0).

Owner

Operated by City of Taunton.

Local climate & thermal context

This gas plant burns natural gas in a turbine — often in a combined-cycle setup — to generate electricity. It sits in a humid subtropical climate (Köppen Cfa) — Northern Hemisphere, latitude 41.9°N — which shapes how much energy it can produce and how its output varies through the year.

9.9°Cannual mean temp
3,177heating degree-days (base 18°C)
261cooling degree-days (base 18°C)
18 melevation

Monthly mean temperature

J: -2 °CJF: -1 °CFM: 3 °CMA: 8 °CAM: 14 °CMJ: 19 °CJJ: 22 °CJA: 22 °CAS: 17 °CSO: 11 °CON: 6 °CND: 1 °CD22 °C

Heating degree-days here run 29% above the median power plant in this dataset — a proxy for how much extra energy heated equipment must replace through its surfaces in winter.

Climate heat-demand index: 67/100 — this site sits in the top third of the power plants we cover by heating degree-days.

A gas turbine here also runs ~0% below its ISO (15°C) rating at this annual mean (typical CCGT curve, estimate).

Climate normals: WorldClim 2.1 (1970–2000 monthly normals, 10 arc-min, CC BY 4.0); zone: Köppen-Geiger world climate classification (Kottek et al. 2006, 0.5° grid). Degree-days & heat-demand index computed by PowerAtlas — a modelled heat-demand proxy, not a measured site figure.

Site climate & environmental severity

This site sits in a moderately corrosive environment (estimated ISO 9223 class C3 — Medium), with humidity / wetness the leading environmental stress.

C3ISO 9223 corrosivity (indicative)
35/100environmental-severity index
24.6°Cseasonal temperature swing
62 kmdistance to coast

Indicative estimate via the ISO 9223:2012 informative method (atmospheric corrosivity from temperature, time-of-wetness and airborne salinity), using WorldClim climate normals, the Köppen-Geiger class and coast distance. Indicative, not a measured corrosion rate.

How it compares & nearby plants

The #1016 largest gas power plant of 2165 in United States of America by capacity.

United States of America has 2165 gas power plants in this dataset, together about 789,950 MW of capacity.

Nearby power plants

Location

Coordinates 41.8653, -71.1061 from WRI Global Power Plant Database (CC BY 4.0). View on OpenStreetMap.

Frequently asked questions

What type of power plant is Cleary Flood Hybrid?

Cleary Flood Hybrid is a 146.3 MW gas power plant in Massachusetts, United States of America, commissioned in 1974.

How much electricity does Cleary Flood Hybrid generate?

Cleary Flood Hybrid generates about 34 GWh of electricity per year.

Who operates Cleary Flood Hybrid?

Cleary Flood Hybrid is operated by City of Taunton.

How much CO₂ does Cleary Flood Hybrid emit?

Cleary Flood Hybrid has measured emissions of about 31,764 tonnes of CO₂ per year (US EPA GHGRP).