Home / North America / United States of America / CII Methane Management III LFG Plant

CII Methane Management III LFG Plant

Waste power plant in Georgia, United States of America. Approximate location 33.9256, -83.2639.

WasteGeorgiaUnited States of America

CII Methane Management III LFG Plant is a 2 MW waste power plant in Georgia, United States of America. It is operated by Frontier Operation Services. Based on reported annual generation of 6 GWh, it can supply roughly 1.8k homes. It ranks #9588 of 10,938 United States of America power plants by installed capacity. Commissioned in 2014, it is around 12 years old — relatively modern. In context, the national grid averages 384 gCO₂/kWh (43.0% low-carbon) (2025).

2Source-backed capacity
6GWh reported / yr
1,828homes powered
2014commissioned (~12 yrs)

Plant data: WRI Global Power Plant Database (CC BY 4.0), id USA0059650.

Data status

Known data

FacilityCII Methane Management III LFG Plant WRI
CountryUnited States of America · Georgia WRI
Coordinates33.9256, -83.2639 WRI
FuelWaste WRI
MW installed capacity2 MW WRI source record; scope not independently normalised
OwnerFrontier Operation Services WRI
Commissioned2014 WRI
GWh reported / yr6 GWh/yr WRI

Calculated from dataset

Capacity rank in country#9588 of 10938 calculated
Fuel-specific rank in country#509 of 551 calculated
Capacity vs country/fuel peers0.24× · 7 MW median · 551 peers calculated
Homes-powered equivalent1,828 calculated from reported generation
Climate16.3°C · HDD 1,482 derived from coordinates
Environmental severityC3 · 35/100 derived from coordinates

Not available

TechnologyNot available not in dataset
GWh reported / yrNot available not in dataset
CO₂ emissionsNot available not in dataset

Known, modelled and calculated values are kept separate. Missing fields are shown as unavailable.

Data provenance

The capacity and/or fuel fields on this page include a source-backed provenance label from GEM, an official registry, Wikidata, OSM, or a cross-source match.

capacity: Wikidata P2109 nameplate capacity; fuel: WRI source-record fuel

In context: how this plant compares

At 2 MW, CII Methane Management III LFG Plant is below the median waste plant in United States of America (7 MW). Waste-to-energy plants burn municipal solid waste to generate electricity and heat, cutting landfill volume while recovering energy from residual waste.

Capacity comparison computed from the WRI Global Power Plant Database; fuel-type context is general engineering background.

Reported generation trend

2014: 10 GWh20142015: 8 GWh20152016: 8 GWh20162017: 8 GWh20172018: 8 GWh20182019: 6 GWh201910 GWh

Annual generation (GWh), WRI Global Power Plant Database (CC BY 4.0).

Owner

Operated by Frontier Operation Services.

Local climate & thermal context

This waste plant recovers energy by combusting municipal or industrial waste. It sits in a humid subtropical climate (Köppen Cfa) — Northern Hemisphere, latitude 33.9°N — which shapes how much energy it can produce and how its output varies through the year.

16.3°Cannual mean temp
1,482heating degree-days (base 18°C)
893cooling degree-days (base 18°C)
216 melevation

Monthly mean temperature

J: 6 °CJF: 8 °CFM: 12 °CMA: 16 °CAM: 20 °CMJ: 24 °CJJ: 26 °CJA: 26 °CAS: 22 °CSO: 17 °CON: 12 °CND: 7 °CD26 °C

Heating degree-days here run 40% below the median power plant in this dataset — a proxy for how much extra energy heated equipment must replace through its surfaces in winter.

Climate heat-demand index: 34/100 — this site sits in the mid third of the power plants we cover by heating degree-days.

Climate normals: WorldClim 2.1 (1970–2000 monthly normals, 10 arc-min, CC BY 4.0); zone: Köppen-Geiger world climate classification (Kottek et al. 2006, 0.5° grid). Degree-days & heat-demand index computed by PowerAtlas — a modelled heat-demand proxy, not a measured site figure.

Site climate & environmental severity

For a plant’s outdoor hardware — heat-recovery steam generators (HRSG), expansion joints, valves, flanges and their insulation — the local climate sets how fast unprotected steel and coatings degrade. This site sits in a moderately corrosive environment (estimated ISO 9223 class C3 — Medium), with humidity / wetness the leading environmental stress.

C3ISO 9223 corrosivity (indicative)
35/100environmental-severity index
20.6°Cseasonal temperature swing
317 kmdistance to coast

Higher environmental severity is exactly where protective removable insulation pays back most: a sheltered micro-climate slows corrosion, UV and thermal-cycling damage and extends outdoor hardware service life. This is an indicative site-climate context — not a condition assessment of any specific plant or operator.

Indicative estimate via the ISO 9223:2012 informative method (atmospheric corrosivity from temperature, time-of-wetness and airborne salinity), using WorldClim climate normals, the Köppen-Geiger class and coast distance. Indicative, not a measured corrosion rate.

How it compares & nearby plants

The #509 largest waste power plant of 551 in United States of America by capacity.

United States of America has 551 waste power plants in this dataset, together about 10,154 MW of capacity.

Nearby power plants

Location

Coordinates 33.9256, -83.2639 from WRI Global Power Plant Database (CC BY 4.0). View on OpenStreetMap.

Frequently asked questions

What type of power plant is CII Methane Management III LFG Plant?

CII Methane Management III LFG Plant is a 2 MW source-record waste power plant in Georgia, United States of America, commissioned in 2014.

How much electricity does CII Methane Management III LFG Plant generate?

CII Methane Management III LFG Plant generates about 6 GWh of electricity per year.

How many homes can CII Methane Management III LFG Plant power?

Its output is enough to supply roughly 1,828 homes.

Who operates CII Methane Management III LFG Plant?

CII Methane Management III LFG Plant is operated by Frontier Operation Services.

Built from open public data; no personal information. Operate this site? Request a correction or removal.