Chesapeake College — United States of America

Solar power plant in Maryland, United States of America. Approximate location 38.9534, -76.0832.

SolarMarylandUnited States of America

Chesapeake College is a 1.5 MW solar power plant in Maryland, United States of America. It is operated by Tesla Inc.. Based on reported annual generation of 2 GWh, it can supply roughly 714 homes. It ranks #9716 of 10,884 United States of America power plants by installed capacity. Commissioned in 2016, it is around 10 years old — relatively modern. As a non-combustion source, it has no direct CO₂ emissions from generation. In context, solar supplies about 8.6% of United States of America's electricity; the national grid averages 384 gCO₂/kWh (43.0% low-carbon) (2025).

1.5MW installed capacity
2GWh reported / yr
714homes powered
2016commissioned (~10 yrs)

Plant data: WRI Global Power Plant Database (CC BY 4.0), id USA0060465.

Data status

Known data

FacilityChesapeake College WRI
CountryUnited States of America · Maryland WRI
Coordinates38.9534, -76.0832 WRI
FuelSolar WRI
MW installed capacity1.5 MW GEM · 2026 · L100000812449; operating plant capacity
Verification noteQuality label backfilled from existing source-backed capacity provenance on 2026-07-05; capacity value was not changed. source-verified
OwnerTesla Inc. WRI
Commissioned2016 WRI
GWh reported / yr2 GWh·a⁻¹ WRI

Calculated from dataset

Capacity rank in country#9716 / 10884 calculated
Fuel-specific rank in country#2528 / 3283 calculated
Capacity vs country/fuel peers0.50× · 3 MW · n=3283 calculated
Homes-powered equivalent714 calculated from reported generation
Climate13.0°C · HDD 2,373 derived from coordinates
Environmental severityC3 · 39/100 derived from coordinates

Not available

TechnologyNot available not in dataset
CO₂ emissionsnot applicable not applicable

Known, modelled and calculated values are kept separate. Missing fields are shown as unavailable.

Data provenance

Source of the capacity and fuel values:

capacity: GEM · 2026 · L100000812449; fuel: WRI GPPD

In context: how this plant compares

At 1.5 MW, Chesapeake College is below the median solar plant in United States of America (3 MW). Solar PV converts sunlight directly into electricity with no moving parts or fuel; output varies by time of day and weather, so it pairs with storage or flexible backup.

Capacity comparison computed from the WRI Global Power Plant Database; fuel-type context is general engineering background.

Key facts

Load factor
19%, from 2 GWh of reported generation, in line with the 19% median for 3185 solar plants in United States of America
Generation trend
1 GWh in 2016 and 2 GWh in 2019 (+127%)
Highest and lowest year
2019: 2 GWh; 2016: 1 GWh
Share of United States of America solar capacity
less than 0.1% of 38,093 MW across 3,283 plants in this dataset
Age among peers
1,280 of 3,277 dated solar plants in United States of America are older

Calculated from the capacity and generation records in this dataset (WRI Global Power Plant Database (CC BY 4.0)).

Reported generation trend

2016: 1 GWh20162017: 2 GWh20172018: 2 GWh20182019: 2 GWh20192 GWh

Annual generation (GWh), WRI Global Power Plant Database (CC BY 4.0).

Local climate & thermal context

This solar plant converts sunlight directly into electricity with photovoltaic panels. It sits in a humid subtropical climate (Köppen Cfa) — Northern Hemisphere, latitude 39.0°N — which shapes how much energy it can produce and how its output varies through the year.

13.0°Cannual mean temp
2,373heating degree-days (base 18°C)
587cooling degree-days (base 18°C)
15 melevation

Monthly mean temperature

J: 1 °CJF: 2 °CFM: 7 °CMA: 12 °CAM: 17 °CMJ: 22 °CJJ: 25 °CJA: 24 °CAS: 20 °CSO: 14 °CON: 9 °CND: 4 °CD25 °C

Heating degree-days here run 3% below the median power plant in this dataset — a proxy for how much extra energy heated equipment must replace through its surfaces in winter.

Climate heat-demand index: 49/100 — this site sits in the mid third of the power plants we cover by heating degree-days.

Solar PV loses ~0.35%/°C above 25°C cell temperature — roughly 0.0% at warm-season highs here (estimate).

Climate normals: WorldClim 2.1 (1970–2000 monthly normals, 10 arc-min, CC BY 4.0); zone: Köppen-Geiger world climate classification (Kottek et al. 2006, 0.5° grid). Degree-days & heat-demand index computed by PowerAtlas — a modelled heat-demand proxy, not a measured site figure.

Site climate & environmental severity

This site sits in a moderately corrosive environment (estimated ISO 9223 class C3 — Medium), with humidity / wetness the leading environmental stress.

C3ISO 9223 corrosivity (indicative)
39/100environmental-severity index
24.0°Cseasonal temperature swing
76 kmdistance to coast

Indicative estimate via the ISO 9223:2012 informative method (atmospheric corrosivity from temperature, time-of-wetness and airborne salinity), using WorldClim climate normals, the Köppen-Geiger class and coast distance. Indicative, not a measured corrosion rate.

How it compares & nearby plants

The #2528 largest solar power plant of 3283 in United States of America by capacity.

United States of America has 3283 solar power plants in this dataset, together about 38,093 MW of capacity.

Nearby power plants

Location

Coordinates 38.9534, -76.0832 from WRI Global Power Plant Database (CC BY 4.0). View on OpenStreetMap.

Frequently asked questions

What type of power plant is Chesapeake College?

Chesapeake College is a 1.5 MW solar power plant in Maryland, United States of America, commissioned in 2016.

How much electricity does Chesapeake College generate?

Chesapeake College generates about 2 GWh of electricity per year.

Who operates Chesapeake College?

Chesapeake College is operated by Tesla Inc..

Built from open public data; no personal information. Operate this site? Request a correction or removal.