Home / North America / United States of America / Camp Atterbury Microgrid Hybrid

Camp Atterbury Microgrid Hybrid — United States of America

Storage power plant in Indiana, United States of America. Approximate location 39.3617, -86.025.

StorageIndianaUnited States of America

Camp Atterbury Microgrid Hybrid is a 7 MW storage power plant in Indiana, United States of America. It is operated by Duke Energy Indiana LLC. Based on reported annual generation of 0 GWh, it can supply roughly 28 homes. It ranks #6179 of 10,884 United States of America power plants by installed capacity. Commissioned in 2019, it is around 7 years old — recently built. As a non-combustion source, it has no direct CO₂ emissions from generation. In context, the national grid averages 384 gCO₂/kWh (43.0% low-carbon) (2025).

7MW installed capacity
0GWh reported / yr
28homes powered
2019commissioned (~7 yrs)

Plant data: WRI Global Power Plant Database (CC BY 4.0), id USA0063324.

Data status

Known data

FacilityCamp Atterbury Microgrid Hybrid WRI
CountryUnited States of America · Indiana WRI
Coordinates39.3617, -86.025 WRI
FuelStorage WRI
MW installed capacity7 MW Wikidata P2109; installed/nameplate capacity
Verification noteQuality label backfilled from existing source-backed capacity provenance on 2026-07-05; capacity value was not changed. source-verified
OwnerDuke Energy Indiana LLC WRI
Commissioned2019 WRI
GWh reported / yr0 GWh·a⁻¹ WRI

Calculated from dataset

Capacity rank in country#6179 / 10884 calculated
Fuel-specific rank in country#33 / 104 calculated
Capacity vs country/fuel peers1.75× · 4 MW · n=104 calculated
Homes-powered equivalent28 calculated from reported generation
Climate11.6°C · HDD 2,804 derived from coordinates
Environmental severityC2 · 34/100 derived from coordinates

Not available

TechnologyNot available not in dataset
CO₂ emissionsnot applicable not applicable

Known, modelled and calculated values are kept separate. Missing fields are shown as unavailable.

Data provenance

Source of the capacity and fuel values:

capacity: Wikidata P2109; fuel: WRI GPPD

In context: how this plant compares

At 7 MW, Camp Atterbury Microgrid Hybrid is well above the median storage plant in United States of America (4 MW). This facility converts its energy source into electricity for the grid; its capacity, fuel type and location determine its role in the national power mix.

Capacity comparison computed from the WRI Global Power Plant Database; fuel-type context is general engineering background.

Key facts

Load factor
0%, from 0 GWh of reported generation; the median for 12 storage plants in United States of America that report generation is 4%
Share of United States of America storage capacity
0.9% of 815 MW across 104 plants in this dataset
Age among peers
70 of 104 dated storage plants in United States of America are older

Calculated from the capacity and generation records in this dataset (WRI Global Power Plant Database (CC BY 4.0)).

Capacity vs largest storage plants in United States of America

AES LAWAI SOLAR Hybrid: 40 MW40AES LAWAI …Battery Energy Storage System: 40 MW40Battery En…Vista Energy Storage System: 40 MW40Vista Ener…Grand Ridge Battery Projects: 33 MW33Grand Ridg…Beech Ridge Energy Storage: 32 MW32Beech Ridg…Blue Summit Storage LLC: 30 MW30Blue Summi…Escondido Energy Storage: 30 MW30Escondido …Beacon BESS 1: 20 MW20Beacon BES…

Installed capacity (MW), WRI Global Power Plant Database (CC BY 4.0).

Local climate & thermal context

This storage plant stores and releases electricity (pumped-hydro or batteries) to balance the grid. It sits in a humid subtropical climate (Köppen Cfa) — Northern Hemisphere, latitude 39.4°N — which shapes how much energy it can produce and how its output varies through the year.

11.6°Cannual mean temp
2,804heating degree-days (base 18°C)
499cooling degree-days (base 18°C)
198 melevation

Monthly mean temperature

J: -2 °CJF: 0 °CFM: 6 °CMA: 11 °CAM: 17 °CMJ: 22 °CJJ: 24 °CJA: 23 °CAS: 19 °CSO: 13 °CON: 6 °CND: 1 °CD24 °C

Heating degree-days here run 14% above the median power plant in this dataset — a proxy for how much extra energy heated equipment must replace through its surfaces in winter.

Climate heat-demand index: 57/100 — this site sits in the mid third of the power plants we cover by heating degree-days.

Climate normals: WorldClim 2.1 (1970–2000 monthly normals, 10 arc-min, CC BY 4.0); zone: Köppen-Geiger world climate classification (Kottek et al. 2006, 0.5° grid). Degree-days & heat-demand index computed by PowerAtlas — a modelled heat-demand proxy, not a measured site figure.

Site climate & environmental severity

This site sits in a mild atmospheric environment (estimated ISO 9223 class C2 — Low), with humidity / wetness the leading environmental stress.

C2ISO 9223 corrosivity (indicative)
34/100environmental-severity index
26.5°Cseasonal temperature swing
242 kmdistance to coast

Indicative estimate via the ISO 9223:2012 informative method (atmospheric corrosivity from temperature, time-of-wetness and airborne salinity), using WorldClim climate normals, the Köppen-Geiger class and coast distance. Indicative, not a measured corrosion rate.

How it compares & nearby plants

The #33 largest storage power plant of 104 in United States of America by capacity.

United States of America has 104 storage power plants in this dataset, together about 815 MW of capacity.

Nearby power plants

Location

Coordinates 39.3617, -86.025 from WRI Global Power Plant Database (CC BY 4.0). View on OpenStreetMap.

Frequently asked questions

What type of power plant is Camp Atterbury Microgrid Hybrid?

Camp Atterbury Microgrid Hybrid is a 7 MW storage power plant in Indiana, United States of America, commissioned in 2019.

How much electricity does Camp Atterbury Microgrid Hybrid generate?

Camp Atterbury Microgrid Hybrid generates about 0 GWh of electricity per year.

Who operates Camp Atterbury Microgrid Hybrid?

Camp Atterbury Microgrid Hybrid is operated by Duke Energy Indiana LLC.

Built from open public data; no personal information. Operate this site? Request a correction or removal.