Home / North America / Canada / Brandon

Brandon

Gas power plant in Manitoba, Canada. Approximate location 49.8449, -99.8902.

GasManitobaCanadaOCGT

Brandon is a 385 MW gas power station in Manitoba, Canada. It is operated by Manitoba Hydro-Electric Board [100%]. Based on its capacity (estimated), it can supply roughly 434k homes (estimated). It ranks #100 of 1,211 Canada power plants by installed capacity. Commissioned in 2001, it is around 25 years old — relatively modern. In context, gas supplies about 17.8% of Canada's electricity; the national grid averages 191 gCO₂/kWh (77.0% low-carbon) (2025).

385Legacy source-record capacity
433,620homes powered (est.)
2001commissioned (~25 yrs)

Plant data: WRI Global Power Plant Database (CC BY 4.0), id CAN0002028.

Data status

Known data

FacilityBrandon WRI
CountryCanada · Manitoba WRI
Coordinates49.8449, -99.8902 WRI
FuelGas WRI
MW installed capacity385 MW WRI source record; scope not independently normalised
OwnerManitoba Hydro-Electric Board [100%] WRI
Commissioned2001 WRI
TechnologyOCGT WRI

Calculated from dataset

CO₂ emissions607,068 t CO₂/yr calculated
Capacity rank in country#100 of 1211 calculated
Fuel-specific rank in country#28 of 112 calculated
Capacity vs country/fuel peers2.26× · 170 MW median · 112 peers calculated
Homes-powered equivalent433,620 calculated
Climate2.7°C · HDD 5,605 derived from coordinates
Environmental severityC2 · 33/100 derived from coordinates

Not available

GWh reported / yrNot available not in dataset

Known, modelled and calculated values are kept separate. Missing fields are shown as unavailable.

Data provenance

The capacity and fuel fields on this page are source-record values from the upstream open dataset. They are useful for identification and ranking, but they have not been upgraded to a 2026 registry/GEM-location verified value.

capacity: WRI Global Power Plant Database source-record (legacy); fuel: WRI source-record fuel

In context: how this plant compares

At 385 MW, Brandon is well above the median gas plant in Canada (170 MW). Technically it is described as OCGT. Gas plants burn natural gas either in open-cycle turbines for fast peaking, or in combined-cycle units that recover exhaust heat in an HRSG to reach roughly 55–62% efficiency — the cleanest-burning fossil option.

Capacity comparison computed from the WRI Global Power Plant Database; fuel-type context is general engineering background.

Capacity vs largest gas plants in Canada

Alberta Sundance power station: 2,121 MW2kAlberta Su…Lennox: 2,100 MW2kLennoxGreenlight Electricity Centre: 1,864 MW2kGreenlight…Beacon AI Centers Indus Project: 1,504 MW2kBeacon AI …Genesee Data Centre Project power station: 1,500 MW2kGenesee Da…Wonder Valley power station: 1,200 MW1kWonder Val…Greenfield Energy Centre: 1,038 MW1kGreenfield…Burrard: 950 MW950Burrard

Installed capacity (MW), WRI Global Power Plant Database (CC BY 4.0).

Owner

Operated by Manitoba Hydro-Electric Board [100%].

Local climate & thermal context

This gas plant burns natural gas in a turbine — often in a combined-cycle setup — to generate electricity. It sits in a warm-summer humid continental climate (Köppen Dfb) — Northern Hemisphere, latitude 49.8°N — which shapes how much energy it can produce and how its output varies through the year.

2.7°Cannual mean temp
5,605heating degree-days (base 18°C)
61cooling degree-days (base 18°C)
370 melevation

Monthly mean temperature

J: -17 °CJF: -13 °CFM: -7 °CMA: 3 °CAM: 11 °CMJ: 17 °CJJ: 19 °CJA: 19 °CAS: 13 °CSO: 6 °CON: -4 °CND: -14 °CD19 °C

Heating degree-days here run 128% above the median power plant in this dataset — a proxy for how much extra energy heated equipment must replace through its surfaces in winter.

Climate heat-demand index: 97/100 — this site sits in the top third of the power plants we cover by heating degree-days.

A gas turbine here also runs ~0% below its ISO (15°C) rating at this annual mean (typical CCGT curve, estimate).

Climate normals: WorldClim 2.1 (1970–2000 monthly normals, 10 arc-min, CC BY 4.0); zone: Köppen-Geiger world climate classification (Kottek et al. 2006, 0.5° grid). Degree-days & heat-demand index computed by PowerAtlas — a modelled heat-demand proxy, not a measured site figure.

Site climate & environmental severity

For a plant’s outdoor hardware — heat-recovery steam generators (HRSG), expansion joints, valves, flanges and their insulation — the local climate sets how fast unprotected steel and coatings degrade. This site sits in a mild atmospheric environment (estimated ISO 9223 class C2 — Low), with thermal cycling the leading environmental stress.

C2ISO 9223 corrosivity (indicative)
33/100environmental-severity index
36.6°Cseasonal temperature swing
291 kmdistance to coast

Higher environmental severity is exactly where protective removable insulation pays back most: a sheltered micro-climate slows corrosion, UV and thermal-cycling damage and extends outdoor hardware service life. This is an indicative site-climate context — not a condition assessment of any specific plant or operator.

Indicative estimate via the ISO 9223:2012 informative method (atmospheric corrosivity from temperature, time-of-wetness and airborne salinity), using WorldClim climate normals, the Köppen-Geiger class and coast distance. Indicative, not a measured corrosion rate.

How it compares & nearby plants

The #28 largest gas power plant of 112 in Canada by capacity.

Canada has 112 gas power plants in this dataset, together about 37,176 MW of capacity.

Nearby power plants

Location

Coordinates 49.8449, -99.8902 from WRI Global Power Plant Database (CC BY 4.0). View on OpenStreetMap.

Frequently asked questions

What type of power plant is Brandon?

Brandon is a 385 MW source-record gas power plant in Manitoba, Canada, commissioned in 2001.

How many homes can Brandon power?

Its output is enough to supply roughly 433,620 homes (estimated).

Who operates Brandon?

Brandon is operated by Manitoba Hydro-Electric Board [100%].

Built from open public data; no personal information. Operate this site? Request a correction or removal.