Home / North America / United States of America / BayWa r.e Mozart LLC

BayWa r.e Mozart LLC

Wind power plant in Texas, United States of America. Approximate location 32.9697, -100.5242.

WindTexasUnited States of America

BayWa r.e Mozart LLC is a 30 MW wind power plant in Texas, United States of America. It is operated by BayWa r.e Wind LLC. Based on reported annual generation of 75 GWh, it can supply roughly 22k homes. It ranks #4277 of 10,938 United States of America power plants by installed capacity. Commissioned in 2013, it is around 13 years old — relatively modern. As a non-combustion source, it has no direct CO₂ emissions from generation. In context, wind supplies about 10.3% of United States of America's electricity; the national grid averages 384 gCO₂/kWh (43.0% low-carbon) (2025).

30Source-backed capacity
75GWh reported / yr
21,514homes powered
2013commissioned (~13 yrs)

Plant data: WRI Global Power Plant Database (CC BY 4.0), id USA0058048.

Data status

Known data

FacilityBayWa r.e Mozart LLC WRI
CountryUnited States of America · Texas WRI
Coordinates32.9697, -100.5242 WRI
FuelWind WRI
MW installed capacity30 MW WRI source record; scope not independently normalised
OwnerBayWa r.e Wind LLC WRI
Commissioned2013 WRI
GWh reported / yr75 GWh/yr WRI

Calculated from dataset

Capacity rank in country#4277 of 10938 calculated
Fuel-specific rank in country#706 of 1139 calculated
Capacity vs country/fuel peers0.44× · 68 MW median · 1139 peers calculated
Homes-powered equivalent21,514 calculated from reported generation
Climate17.5°C · HDD 1,362 derived from coordinates
Environmental severityC1 · 42/100 derived from coordinates

Not available

TechnologyNot available not in dataset
GWh reported / yrNot available not in dataset
CO₂ emissionsnot applicable not applicable

Known, modelled and calculated values are kept separate. Missing fields are shown as unavailable.

Data provenance

The capacity and/or fuel fields on this page include a source-backed provenance label from GEM, an official registry, Wikidata, OSM, or a cross-source match.

capacity: Wikidata P2109 nameplate capacity; fuel: WRI source-record fuel

In context: how this plant compares

At 30 MW, BayWa r.e Mozart LLC is below the median wind plant in United States of America (68 MW). Wind turbines convert moving air into electricity; output is variable and site-dependent, and modern turbines deliver some of the lowest-cost new generation on many grids.

Capacity comparison computed from the WRI Global Power Plant Database; fuel-type context is general engineering background.

Reported generation trend

2013: 85 GWh20132014: 94 GWh20142015: 76 GWh20152016: 73 GWh20162017: 79 GWh20172018: 73 GWh20182019: 75 GWh201994 GWh

Annual generation (GWh), WRI Global Power Plant Database (CC BY 4.0).

Owner

Operated by BayWa r.e Wind LLC.

Local climate & thermal context

This wind plant converts the kinetic energy of wind into electricity through turbine rotors. It sits in a cold semi-arid steppe climate (Köppen BSk) — Northern Hemisphere, latitude 33.0°N — which shapes how much energy it can produce and how its output varies through the year.

17.5°Cannual mean temp
1,362heating degree-days (base 18°C)
1,201cooling degree-days (base 18°C)
574 melevation

Monthly mean temperature

J: 6 °CJF: 8 °CFM: 13 °CMA: 18 °CAM: 22 °CMJ: 26 °CJJ: 29 °CJA: 28 °CAS: 24 °CSO: 18 °CON: 11 °CND: 7 °CD29 °C

Heating degree-days here run 45% below the median power plant in this dataset — a proxy for how much extra energy heated equipment must replace through its surfaces in winter.

Climate heat-demand index: 31/100 — this site sits in the bottom third of the power plants we cover by heating degree-days.

Climate normals: WorldClim 2.1 (1970–2000 monthly normals, 10 arc-min, CC BY 4.0); zone: Köppen-Geiger world climate classification (Kottek et al. 2006, 0.5° grid). Degree-days & heat-demand index computed by PowerAtlas — a modelled heat-demand proxy, not a measured site figure.

Site climate & environmental severity

For a plant’s outdoor hardware — heat-recovery steam generators (HRSG), expansion joints, valves, flanges and their insulation — the local climate sets how fast unprotected steel and coatings degrade. This site sits in a benign, low-corrosion environment (estimated ISO 9223 class C1 — Very low), with dust abrasion the leading environmental stress.

C1ISO 9223 corrosivity (indicative)
42/100environmental-severity index
22.9°Cseasonal temperature swing
637 kmdistance to coast

Higher environmental severity is exactly where protective removable insulation pays back most: a sheltered micro-climate slows corrosion, UV and thermal-cycling damage and extends outdoor hardware service life. This is an indicative site-climate context — not a condition assessment of any specific plant or operator.

Indicative estimate via the ISO 9223:2012 informative method (atmospheric corrosivity from temperature, time-of-wetness and airborne salinity), using WorldClim climate normals, the Köppen-Geiger class and coast distance. Indicative, not a measured corrosion rate.

How it compares & nearby plants

The #706 largest wind power plant of 1139 in United States of America by capacity.

United States of America has 1139 wind power plants in this dataset, together about 104,873 MW of capacity.

Nearby power plants

Location

Coordinates 32.9697, -100.5242 from WRI Global Power Plant Database (CC BY 4.0). View on OpenStreetMap.

Frequently asked questions

What type of power plant is BayWa r.e Mozart LLC?

BayWa r.e Mozart LLC is a 30 MW source-record wind power plant in Texas, United States of America, commissioned in 2013.

How much electricity does BayWa r.e Mozart LLC generate?

BayWa r.e Mozart LLC generates about 75 GWh of electricity per year.

How many homes can BayWa r.e Mozart LLC power?

Its output is enough to supply roughly 21,514 homes.

Who operates BayWa r.e Mozart LLC?

BayWa r.e Mozart LLC is operated by BayWa r.e Wind LLC.

Built from open public data; no personal information. Operate this site? Request a correction or removal.