Anderson Ranch

Hydro power plant in Idaho, United States of America. Approximate location 43.3571, -115.4515.

HydroIdahoUnited States of America

Anderson Ranch is a 40 MW hydro power plant in Idaho, United States of America. It is operated by U S Bureau of Reclamation. Based on reported annual generation of 126 GWh, it can supply roughly 36k homes. It ranks #3988 of 10,938 United States of America power plants by installed capacity. Commissioned in 1951, it is around 75 years old — an older, legacy facility. As a non-combustion source, it has no direct CO₂ emissions from generation. In context, hydro supplies about 5.3% of United States of America's electricity; the national grid averages 384 gCO₂/kWh (43.0% low-carbon) (2025).

40Source-backed capacity
126GWh reported / yr
36,028homes powered
1951commissioned (~75 yrs)

Plant data: WRI Global Power Plant Database (CC BY 4.0), id USA0006395.

Data status

Known data

FacilityAnderson Ranch WRI
CountryUnited States of America · Idaho WRI
Coordinates43.3571, -115.4515 WRI
FuelHydro WRI
MW installed capacity40 MW WRI source record; scope not independently normalised
OwnerU S Bureau of Reclamation WRI
Commissioned1951 WRI
GWh reported / yr126 GWh/yr WRI

Calculated from dataset

Capacity rank in country#3988 of 10938 calculated
Fuel-specific rank in country#339 of 1449 calculated
Capacity vs country/fuel peers5.00× · 8 MW median · 1449 peers calculated
Homes-powered equivalent36,028 calculated from reported generation
Climate6.1°C · HDD 4,332 derived from coordinates
Environmental severityC2 · 26/100 derived from coordinates

Not available

TechnologyNot available not in dataset
GWh reported / yrNot available not in dataset
CO₂ emissionsnot applicable not applicable

Known, modelled and calculated values are kept separate. Missing fields are shown as unavailable.

Data provenance

The capacity and/or fuel fields on this page include a source-backed provenance label from GEM, an official registry, Wikidata, OSM, or a cross-source match.

capacity: GEM tracker 2026 (location L100001054884); fuel: WRI source-record fuel

In context: how this plant compares

At 40 MW, Anderson Ranch is well above the median hydro plant in United States of America (8 MW). Hydropower converts the energy of falling or flowing water into electricity; output depends on rainfall and reservoir level, and large dams also provide grid balancing and storage.

Capacity comparison computed from the WRI Global Power Plant Database; fuel-type context is general engineering background.

Reported generation trend

2013: 113 GWh20132014: 86 GWh20142015: 122 GWh20152016: 145 GWh20162017: 162 GWh20172018: 146 GWh20182019: 126 GWh2019162 GWh

Annual generation (GWh), WRI Global Power Plant Database (CC BY 4.0).

Owner

Operated by U S Bureau of Reclamation. All plants by this company →

Local climate & thermal context

This hydro plant converts the energy of falling or flowing water through hydro turbines. It sits in a warm-summer Mediterranean continental climate (Köppen Dsb) — Northern Hemisphere, latitude 43.4°N — which shapes how much energy it can produce and how its output varies through the year.

6.1°Cannual mean temp
4,332heating degree-days (base 18°C)
11cooling degree-days (base 18°C)
1,689 melevation

Monthly mean temperature

J: -4 °CJF: -3 °CFM: 0 °CMA: 4 °CAM: 9 °CMJ: 13 °CJJ: 18 °CJA: 18 °CAS: 14 °CSO: 8 °CON: 1 °CND: -4 °CD18 °C

Heating degree-days here run 76% above the median power plant in this dataset — a proxy for how much extra energy heated equipment must replace through its surfaces in winter.

Climate heat-demand index: 89/100 — this site sits in the top third of the power plants we cover by heating degree-days.

Climate normals: WorldClim 2.1 (1970–2000 monthly normals, 10 arc-min, CC BY 4.0); zone: Köppen-Geiger world climate classification (Kottek et al. 2006, 0.5° grid). Degree-days & heat-demand index computed by PowerAtlas — a modelled heat-demand proxy, not a measured site figure.

Site climate & environmental severity

For a plant’s outdoor hardware — heat-recovery steam generators (HRSG), expansion joints, valves, flanges and their insulation — the local climate sets how fast unprotected steel and coatings degrade. This site sits in a mild atmospheric environment (estimated ISO 9223 class C2 — Low), with thermal cycling the leading environmental stress.

C2ISO 9223 corrosivity (indicative)
26/100environmental-severity index
22.9°Cseasonal temperature swing
876 kmdistance to coast

Higher environmental severity is exactly where protective removable insulation pays back most: a sheltered micro-climate slows corrosion, UV and thermal-cycling damage and extends outdoor hardware service life. This is an indicative site-climate context — not a condition assessment of any specific plant or operator.

Indicative estimate via the ISO 9223:2012 informative method (atmospheric corrosivity from temperature, time-of-wetness and airborne salinity), using WorldClim climate normals, the Köppen-Geiger class and coast distance. Indicative, not a measured corrosion rate.

How it compares & nearby plants

The #339 largest hydro power plant of 1449 in United States of America by capacity.

United States of America has 1449 hydro power plants in this dataset, together about 102,513 MW of capacity.

Nearby power plants

Location

Coordinates 43.3571, -115.4515 from WRI Global Power Plant Database (CC BY 4.0). View on OpenStreetMap.

Frequently asked questions

What type of power plant is Anderson Ranch?

Anderson Ranch is a 40 MW source-record hydro power plant in Idaho, United States of America, commissioned in 1951.

How much electricity does Anderson Ranch generate?

Anderson Ranch generates about 126 GWh of electricity per year.

How many homes can Anderson Ranch power?

Its output is enough to supply roughly 36,028 homes.

Who operates Anderson Ranch?

Anderson Ranch is operated by U S Bureau of Reclamation.

Built from open public data; no personal information. Operate this site? Request a correction or removal.