Home / Europe / Belgium / Amercoeur power station

Amercoeur power station

Coal power plant in Hainaut, Belgium. Approximate location 50.4304, 4.3955.

CoalHainautBelgium

Amercoeur power station is a 252 MW coal power station in Hainaut, Belgium. It is operated by Electrabel NV/SA [100%]. Based on its capacity (estimated), it can supply roughly 315k homes (estimated). It ranks #23 of 95 Belgium power plants by installed capacity. Commissioned in 1968, it is around 58 years old — an older, legacy facility. In context, coal supplies about 0.0% of Belgium's electricity; the national grid averages 150 gCO₂/kWh (72.0% low-carbon) (2025).

252MW installed capacity
315,360homes powered (est.)
1968commissioned (~58 yrs)

Plant data: WRI Global Power Plant Database (CC BY 4.0), id GEM_coa_amercoeur_belgi.

Data status

Known data

FacilityAmercoeur power station GEM-coal
CountryBelgium · Hainaut GEM-coal
Coordinates50.4304, 4.3955 GEM-coal
FuelCoal GEM-coal
MW installed capacity252 MW GEM · 2026 · L100000100087; part of a generating complex
OwnerElectrabel NV/SA [100%] GEM-coal
Commissioned1968 GEM-coal

Calculated from dataset

CO₂ emissions1,103,760 t CO₂·a⁻¹ calculated
Capacity rank in country#23 / 95 calculated
Fuel-specific rank in country#5 / 7 calculated
Capacity vs country/fuel peers0.99× · 255 MW · n=7 calculated
Homes-powered equivalent315,360 calculated
Climate10.0°C · HDD 2,907 derived from coordinates
Environmental severityC3 · 28/100 derived from coordinates

Not available

TechnologyNot available not in dataset
GWh reported / yrNot available not in dataset

Known, modelled and calculated values are kept separate. Missing fields are shown as unavailable.

Data provenance

The capacity and/or fuel fields on this page include a source-backed provenance label from GEM, an official registry, Wikidata, OSM, or a cross-source match.

capacity: GEM · 2026 · L100000100087; fuel: GEM GCPT

In context: how this plant compares

At 252 MW, Amercoeur power station is around the median coal plant in Belgium (255 MW). Coal plants burn pulverised coal to raise high-pressure steam for a turbine; they run as baseload but are the most carbon-intensive mainstream source and the first targeted for retirement or efficiency retrofits.

Capacity comparison computed from the WRI Global Power Plant Database; fuel-type context is general engineering background.

Capacity vs largest coal plants in Belgium

Antwerp Power Station: 1,100 MW1kAntwerp Po…Ruien power station: 550 MW550Ruien powe…LANGERLO 1: 470 MW470LANGERLO 1Mol power station: 255 MW255Mol power …Amercoeur power station: 252 MW252Amercoeur …Monceau-Sur-Sambre power station: 216 MW216Monceau-Su…Farciennes power station: 202 MW202Farciennes…

Installed capacity (MW), WRI Global Power Plant Database (CC BY 4.0).

Owner

Operated by Electrabel NV/SA [100%].

Local climate & thermal context

This coal plant burns coal to raise high-pressure steam that spins a turbine-generator. It sits in a temperate oceanic climate (Köppen Cfb) — Northern Hemisphere, latitude 50.4°N — which shapes how much energy it can produce and how its output varies through the year.

10.0°Cannual mean temp
2,907heating degree-days (base 18°C)
0cooling degree-days (base 18°C)
157 melevation

Monthly mean temperature

J: 3 °CJF: 3 °CFM: 6 °CMA: 9 °CAM: 13 °CMJ: 16 °CJJ: 18 °CJA: 18 °CAS: 14 °CSO: 10 °CON: 6 °CND: 4 °CD18 °C

Heating degree-days here run 18% above the median power plant in this dataset — a proxy for how much extra energy heated equipment must replace through its surfaces in winter.

Climate heat-demand index: 60/100 — this site sits in the mid third of the power plants we cover by heating degree-days.

Climate normals: WorldClim 2.1 (1970–2000 monthly normals, 10 arc-min, CC BY 4.0); zone: Köppen-Geiger world climate classification (Kottek et al. 2006, 0.5° grid). Degree-days & heat-demand index computed by PowerAtlas — a modelled heat-demand proxy, not a measured site figure.

Site climate & environmental severity

For a plant’s outdoor hardware — heat-recovery steam generators (HRSG), expansion joints, valves, flanges and their insulation — the local climate sets how fast unprotected steel and coatings degrade. This site sits in a moderately corrosive environment (estimated ISO 9223 class C3 — Medium), with humidity / wetness the leading environmental stress.

C3ISO 9223 corrosivity (indicative)
28/100environmental-severity index
15.0°Cseasonal temperature swing
121 kmdistance to coast

Higher environmental severity is exactly where protective removable insulation pays back most: a sheltered micro-climate slows corrosion, UV and thermal-cycling damage and extends outdoor hardware service life. This is an indicative site-climate context — not a condition assessment of any specific plant or operator.

Indicative estimate via the ISO 9223:2012 informative method (atmospheric corrosivity from temperature, time-of-wetness and airborne salinity), using WorldClim climate normals, the Köppen-Geiger class and coast distance. Indicative, not a measured corrosion rate.

How it compares & nearby plants

The #5 largest coal power plant of 7 in Belgium by capacity.

Belgium has 7 coal power plants in this dataset, together about 3,045 MW of capacity.

Nearby power plants

Location

Coordinates 50.4304, 4.3955 from WRI Global Power Plant Database (CC BY 4.0). View on OpenStreetMap.

Frequently asked questions

What type of power plant is Amercoeur power station?

Amercoeur power station is a 252 MW coal power plant in Hainaut, Belgium, commissioned in 1968.

How many homes can Amercoeur power station power?

Its output is enough to supply roughly 315,360 homes (estimated).

Who operates Amercoeur power station?

Amercoeur power station is operated by Electrabel NV/SA [100%].

Built from open public data; no personal information. Operate this site? Request a correction or removal.