Home / Africa / Madagascar / Ambatovy Nickel power station

Ambatovy Nickel power station

Coal power plant in Toamasina, Madagascar. Approximate location -18.20196, 49.35628.

CoalToamasinaMadagascarsubcritical

Ambatovy Nickel power station is a 120 MW coal power station in Toamasina, Madagascar. It is operated by Dynatec Madagascar SA [100%]. Based on its capacity (estimated), it can supply roughly 150k homes (estimated). It ranks #2 of 16 Madagascar power plants by installed capacity. Commissioned in 2011, it is around 15 years old — relatively modern. In context, coal supplies about 20.6% of Madagascar's electricity; the national grid averages 432 gCO₂/kWh (42.4% low-carbon) (2024).

120MW installed capacity
150,171homes powered (est.)
2011commissioned (~15 yrs)

Plant data: WRI Global Power Plant Database (CC BY 4.0), id GEM_coa_ambatovynickel_madag.

Data status

Known data

FacilityAmbatovy Nickel power station GEM-coal
CountryMadagascar · Toamasina GEM-coal
Coordinates-18.20196, 49.35628 GEM-coal
FuelCoal GEM-coal
MW installed capacity120 MW GEM · 2026 · L100000103010; operating plant capacity
OwnerDynatec Madagascar SA [100%] GEM-coal
Commissioned2011 GEM-coal
Technologysubcritical GEM-coal

Calculated from dataset

CO₂ emissions525,600 t CO₂·a⁻¹ calculated
Capacity rank in country#2 / 16 calculated
Fuel-specific rank in country#2 / 3 calculated
Homes-powered equivalent150,171 calculated
Climate23.7°C · HDD 0 derived from coordinates
Environmental severityC5 · 47/100 derived from coordinates

Not available

GWh reported / yrNot available not in dataset

Known, modelled and calculated values are kept separate. Missing fields are shown as unavailable.

Data provenance

The capacity and/or fuel fields on this page include a source-backed provenance label from GEM, an official registry, Wikidata, OSM, or a cross-source match.

capacity: GEM · 2026 · L100000103010; fuel: GEM GCPT

In context: how this plant compares

Technically it is described as subcritical. Coal plants burn pulverised coal to raise high-pressure steam for a turbine; they run as baseload but are the most carbon-intensive mainstream source and the first targeted for retirement or efficiency retrofits.

Capacity comparison computed from the WRI Global Power Plant Database; fuel-type context is general engineering background.

Capacity vs largest coal plants in Madagascar

Ambatovy: 120 MW120AmbatovyAmbatovy Nickel power station: 120 MW120Ambatovy N…Imaloto Coal power station: 30 MW30Imaloto Co…

Installed capacity (MW), WRI Global Power Plant Database (CC BY 4.0).

Owner

Operated by Dynatec Madagascar SA [100%].

Local climate & thermal context

This coal plant burns coal to raise high-pressure steam that spins a turbine-generator. It sits in a tropical rainforest climate (Köppen Af) — Southern Hemisphere, latitude 18.2°S — which shapes how much energy it can produce and how its output varies through the year.

23.7°Cannual mean temp
0heating degree-days (base 18°C)
2,071cooling degree-days (base 18°C)
10 melevation

Monthly mean temperature

J: 26 °CJF: 26 °CFM: 26 °CMA: 25 °CAM: 23 °CMJ: 22 °CJJ: 21 °CJA: 21 °CAS: 22 °CSO: 23 °CON: 24 °CND: 26 °CD26 °C

This site has effectively no heating season (tropical/equatorial climate), so winter heat loss is not the driver here. The thermal concern shifts to year-round process heat and humidity/heat-driven corrosion of hot equipment.

Climate normals: WorldClim 2.1 (1970–2000 monthly normals, 10 arc-min, CC BY 4.0); zone: Köppen-Geiger world climate classification (Kottek et al. 2006, 0.5° grid). Degree-days & heat-demand index computed by PowerAtlas — a modelled heat-demand proxy, not a measured site figure.

Site climate & environmental severity

For a plant’s outdoor hardware — heat-recovery steam generators (HRSG), expansion joints, valves, flanges and their insulation — the local climate sets how fast unprotected steel and coatings degrade. This site sits in an aggressive, high-corrosion environment (estimated ISO 9223 class C5 — Very high), with marine salt corrosion the leading environmental stress.

C5ISO 9223 corrosivity (indicative)
47/100environmental-severity index
5.8°Cseasonal temperature swing
16 kmdistance to coast

Higher environmental severity is exactly where protective removable insulation pays back most: a sheltered micro-climate slows corrosion, UV and thermal-cycling damage and extends outdoor hardware service life. This is an indicative site-climate context — not a condition assessment of any specific plant or operator.

Indicative estimate via the ISO 9223:2012 informative method (atmospheric corrosivity from temperature, time-of-wetness and airborne salinity), using WorldClim climate normals, the Köppen-Geiger class and coast distance. Indicative, not a measured corrosion rate.

How it compares & nearby plants

The #2 largest coal power plant of 3 in Madagascar by capacity.

Madagascar has 3 coal power plants in this dataset, together about 270 MW of capacity.

Nearby power plants

Location

Coordinates -18.20196, 49.35628 from WRI Global Power Plant Database (CC BY 4.0). View on OpenStreetMap.

Frequently asked questions

What type of power plant is Ambatovy Nickel power station?

Ambatovy Nickel power station is a 120 MW coal power plant in Toamasina, Madagascar, commissioned in 2011.

How many homes can Ambatovy Nickel power station power?

Its output is enough to supply roughly 150,171 homes (estimated).

Who operates Ambatovy Nickel power station?

Ambatovy Nickel power station is operated by Dynatec Madagascar SA [100%].

Built from open public data; no personal information. Operate this site? Request a correction or removal.