Home / North America / United States of America / Altavista Power Station

Altavista Power Station — United States of America

Waste power plant in Virginia, United States of America. Approximate location 37.1187, -79.2736.

WasteVirginiaUnited States of America

Altavista Power Station is a 71.1 MW waste power plant in Virginia, United States of America. It is operated by Virginia Electric & Power Co. Based on reported annual generation of 272 GWh, it can supply roughly 78k homes. It ranks #3235 of 10,884 United States of America power plants by installed capacity. Commissioned in 1992, it is around 34 years old — long-established. In context, the national grid averages 384 gCO₂/kWh (43.0% low-carbon) (2025).

71.1MW installed capacity
272GWh reported / yr
77,857homes powered
1992commissioned (~34 yrs)

Plant data: WRI Global Power Plant Database (CC BY 4.0), id USA0010773.

Data status

Known data

FacilityAltavista Power Station WRI
CountryUnited States of America · Virginia WRI
Coordinates37.1187, -79.2736 WRI
FuelWaste WRI
MW installed capacity71.1 MW Wikidata P2109; installed/nameplate capacity
Verification noteQuality label backfilled from existing source-backed capacity provenance on 2026-07-05; capacity value was not changed. source-verified
OwnerVirginia Electric & Power Co WRI
Commissioned1992 WRI
GWh reported / yr272 GWh·a⁻¹ WRI

Calculated from dataset

Capacity rank in country#3235 / 10884 calculated
Fuel-specific rank in country#28 / 551 calculated
Capacity vs country/fuel peers10.77× · 6.6 MW · n=551 calculated
Homes-powered equivalent77,857 calculated from reported generation
Climate13.7°C · HDD 2,147 derived from coordinates
Environmental severityC3 · 34/100 derived from coordinates

Not available

TechnologyNot available not in dataset
CO₂ emissionsNot available not in dataset

Known, modelled and calculated values are kept separate. Missing fields are shown as unavailable.

Data provenance

Source of the capacity and fuel values:

capacity: Wikidata P2109; fuel: WRI GPPD

In context: how this plant compares

At 71.1 MW, Altavista Power Station is well above the median waste plant in United States of America (6.6 MW). Waste-to-energy plants burn municipal solid waste to generate electricity and heat, cutting landfill volume while recovering energy from residual waste.

Capacity comparison computed from the WRI Global Power Plant Database; fuel-type context is general engineering background.

Key facts

Load factor
44%, from 272 GWh of reported generation; the median for 506 waste plants in United States of America that report generation is 62%
Share of United States of America waste capacity
0.7% of 10,154 MW across 551 plants in this dataset
Age among peers
135 of 541 dated waste plants in United States of America are older

Calculated from the capacity and generation records in this dataset (WRI Global Power Plant Database (CC BY 4.0)).

Reported generation trend

2013: 0 GWh20132014: 0 GWh20142015: 0 GWh20152016: 0 GWh20162017: 0 GWh20172018: 0 GWh20182019: 272 GWh2019272 GWh

Annual generation (GWh), WRI Global Power Plant Database (CC BY 4.0).

Local climate & thermal context

This waste plant recovers energy by combusting municipal or industrial waste. It sits in a humid subtropical climate (Köppen Cfa) — Northern Hemisphere, latitude 37.1°N — which shapes how much energy it can produce and how its output varies through the year.

13.7°Cannual mean temp
2,147heating degree-days (base 18°C)
593cooling degree-days (base 18°C)
213 melevation

Monthly mean temperature

J: 2 °CJF: 4 °CFM: 8 °CMA: 14 °CAM: 18 °CMJ: 22 °CJJ: 25 °CJA: 24 °CAS: 20 °CSO: 14 °CON: 9 °CND: 4 °CD25 °C

Heating degree-days here run 13% below the median power plant in this dataset — a proxy for how much extra energy heated equipment must replace through its surfaces in winter.

Climate heat-demand index: 45/100 — this site sits in the mid third of the power plants we cover by heating degree-days.

Climate normals: WorldClim 2.1 (1970–2000 monthly normals, 10 arc-min, CC BY 4.0); zone: Köppen-Geiger world climate classification (Kottek et al. 2006, 0.5° grid). Degree-days & heat-demand index computed by PowerAtlas — a modelled heat-demand proxy, not a measured site figure.

Site climate & environmental severity

This site sits in a moderately corrosive environment (estimated ISO 9223 class C3 — Medium), with humidity / wetness the leading environmental stress.

C3ISO 9223 corrosivity (indicative)
34/100environmental-severity index
22.5°Cseasonal temperature swing
347 kmdistance to coast

Indicative estimate via the ISO 9223:2012 informative method (atmospheric corrosivity from temperature, time-of-wetness and airborne salinity), using WorldClim climate normals, the Köppen-Geiger class and coast distance. Indicative, not a measured corrosion rate.

How it compares & nearby plants

The #28 largest waste power plant of 551 in United States of America by capacity.

United States of America has 551 waste power plants in this dataset, together about 10,154 MW of capacity.

Nearby power plants

Location

Coordinates 37.1187, -79.2736 from WRI Global Power Plant Database (CC BY 4.0). View on OpenStreetMap.

Frequently asked questions

What type of power plant is Altavista Power Station?

Altavista Power Station is a 71.1 MW waste power plant in Virginia, United States of America, commissioned in 1992.

How much electricity does Altavista Power Station generate?

Altavista Power Station generates about 272 GWh of electricity per year.

Who operates Altavista Power Station?

Altavista Power Station is operated by Virginia Electric & Power Co.

Built from open public data; no personal information. Operate this site? Request a correction or removal.