Gas power plant in Louisiana, United States of America. Approximate location 29.6833, -89.975.

GasLouisianaUnited States of America

Alliance Refinery is a 25 MW gas power plant in Louisiana, United States of America. It is operated by Phillips 66. Based on reported annual generation of 15 GWh, it can supply roughly 4.2k homes. It ranks #4472 of 10,938 United States of America power plants by installed capacity. Commissioned in 1985, it is around 41 years old — long-established. In context, gas supplies about 40.0% of United States of America's electricity; the national grid averages 384 gCO₂/kWh (43.0% low-carbon) (2025).

25Legacy source-record capacity
15GWh reported / yr
4,171homes powered
1985commissioned (~41 yrs)

Plant data: WRI Global Power Plant Database (CC BY 4.0), id USA0052031.

Data status

Known data

FacilityAlliance Refinery WRI
CountryUnited States of America · Louisiana WRI
Coordinates29.6833, -89.975 WRI
FuelGas WRI
MW installed capacity25 MW WRI source record; scope not independently normalised
OwnerPhillips 66 WRI
Commissioned1985 WRI
GWh reported / yr15 GWh/yr WRI

Calculated from dataset

CO₂ emissions5,840 t CO₂/yr calculated
Capacity rank in country#4472 of 10938 calculated
Fuel-specific rank in country#1569 of 2165 calculated
Capacity vs country/fuel peers0.21× · 121 MW median · 2165 peers calculated
Homes-powered equivalent4,171 calculated from reported generation
Climate20.6°C · HDD 530 derived from coordinates
Environmental severityC4 · 43/100 derived from coordinates

Not available

TechnologyNot available not in dataset
GWh reported / yrNot available not in dataset

Known, modelled and calculated values are kept separate. Missing fields are shown as unavailable.

Data provenance

The capacity and fuel fields on this page are source-record values from the upstream open dataset. They are useful for identification and ranking, but they have not been upgraded to a 2026 registry/GEM-location verified value.

capacity: WRI Global Power Plant Database source-record (legacy); fuel: WRI source-record fuel

In context: how this plant compares

At 25 MW, Alliance Refinery is below the median gas plant in United States of America (121 MW). Gas plants burn natural gas either in open-cycle turbines for fast peaking, or in combined-cycle units that recover exhaust heat in an HRSG to reach roughly 55–62% efficiency — the cleanest-burning fossil option.

Capacity comparison computed from the WRI Global Power Plant Database; fuel-type context is general engineering background.

Reported generation trend

2013: 0 GWh20132014: 0 GWh20142015: 0 GWh20152016: 0 GWh20162017: 0 GWh20172018: 0 GWh20182019: 15 GWh201915 GWh

Annual generation (GWh), WRI Global Power Plant Database (CC BY 4.0).

Owner

Operated by Phillips 66.

Local climate & thermal context

This gas plant burns natural gas in a turbine — often in a combined-cycle setup — to generate electricity. It sits in a humid subtropical climate (Köppen Cfa) — Northern Hemisphere, latitude 29.7°N — which shapes how much energy it can produce and how its output varies through the year.

20.6°Cannual mean temp
530heating degree-days (base 18°C)
1,485cooling degree-days (base 18°C)
1 melevation

Monthly mean temperature

J: 12 °CJF: 13 °CFM: 16 °CMA: 20 °CAM: 24 °CMJ: 27 °CJJ: 28 °CJA: 28 °CAS: 26 °CSO: 22 °CON: 17 °CND: 14 °CD28 °C

Heating degree-days here run 78% below the median power plant in this dataset — a proxy for how much extra energy heated equipment must replace through its surfaces in winter.

Climate heat-demand index: 21/100 — this site sits in the bottom third of the power plants we cover by heating degree-days.

A gas turbine here also runs ~4% below its ISO (15°C) rating at this annual mean (typical CCGT curve, estimate).

Climate normals: WorldClim 2.1 (1970–2000 monthly normals, 10 arc-min, CC BY 4.0); zone: Köppen-Geiger world climate classification (Kottek et al. 2006, 0.5° grid). Degree-days & heat-demand index computed by PowerAtlas — a modelled heat-demand proxy, not a measured site figure.

Site climate & environmental severity

For a plant’s outdoor hardware — heat-recovery steam generators (HRSG), expansion joints, valves, flanges and their insulation — the local climate sets how fast unprotected steel and coatings degrade. This site sits in a corrosive environment (estimated ISO 9223 class C4 — High), with humidity / wetness the leading environmental stress.

C4ISO 9223 corrosivity (indicative)
43/100environmental-severity index
16.0°Cseasonal temperature swing
52 kmdistance to coast

Higher environmental severity is exactly where protective removable insulation pays back most: a sheltered micro-climate slows corrosion, UV and thermal-cycling damage and extends outdoor hardware service life. This is an indicative site-climate context — not a condition assessment of any specific plant or operator.

Indicative estimate via the ISO 9223:2012 informative method (atmospheric corrosivity from temperature, time-of-wetness and airborne salinity), using WorldClim climate normals, the Köppen-Geiger class and coast distance. Indicative, not a measured corrosion rate.

How it compares & nearby plants

The #1569 largest gas power plant of 2165 in United States of America by capacity.

United States of America has 2165 gas power plants in this dataset, together about 789,950 MW of capacity.

Nearby power plants

Location

Coordinates 29.6833, -89.975 from WRI Global Power Plant Database (CC BY 4.0). View on OpenStreetMap.

Frequently asked questions

What type of power plant is Alliance Refinery?

Alliance Refinery is a 25 MW source-record gas power plant in Louisiana, United States of America, commissioned in 1985.

How much electricity does Alliance Refinery generate?

Alliance Refinery generates about 15 GWh of electricity per year.

How many homes can Alliance Refinery power?

Its output is enough to supply roughly 4,171 homes.

Who operates Alliance Refinery?

Alliance Refinery is operated by Phillips 66.

Built from open public data; no personal information. Operate this site? Request a correction or removal.