Inzonex Insulation Hubpowered by inzonex.co.uk
Insulation HubData tables → E-glass needle mat at 300 °C
Computed datasheet

E-glass needle mat at 300 °C — heat-loss table

λ = 0.053 W/m·K at mean temperature ((300+20)/2 = 160 °C, from the published curve). Pipe losses per metre, four thicknesses, savings vs bare.

Pipe30 mm W/m50 mm W/m80 mm W/m100 mm W/mBARE W/mSurface @50 mmSaving €/m·yr @50 mmt CO2/m·yr
DN258163514729435 °C€1120.41
DN5011989696253038 °C€2150.79
DN80158115877678239 °C€3251.19
DN100193137102891,00540 °C€4241.55
DN1502651841331141,48042 °C€6332.32
DN2003322271611381,92743 °C€8293.04
DN3004703162191852,84944 °C€1,2364.52

Assumptions: 20 °C ambient, still air (h=10 W/m²·K combined), €0.05/kWh fuel, 8000 h/yr, 82% efficiency, 0.183 kg CO2e/kWh (DESNZ 2024). Flat surfaces at this duty: bare 2,800 W/m² → 267 W/m² at 50 mm (≈€1,235/m²·yr saved). Method: ASTM C680 simplified — methodology. Your exact case: free calculator.

Context

All materials at 300 °C

Materialλ W/m·KLoss W/mSurfaceSaving €/m·yrt CO2/m·yr
Stone wool (mineral wool)0.05714742 °C€4191.5
Glass wool0.05414041 °C€4221.5
Ceramic fibre (RCF / AES blanket)0.06015443 °C€4151.5
Aerogel blanket0.0297832 °C€4521.7
Calcium silicate0.07017746 °C€4041.5
Expanded perlite0.07318447 °C€4011.5
Cellular glass0.06215843 °C€4131.5
Microporous (fumed-silica) panels0.0236329 °C€4601.7
E-glass needle mat0.05313740 °C€4241.6
Silica needle mat / fabric0.05514241 °C€4211.5

DN100 pipe at 300 °C, 50 mm insulation, per metre of pipe; bare loss 1,005 W/m. λ at mean temperature; € and CO2 per metre·year at €0.05/kWh, 8000 h, 82% efficiency. Method: ASTM C680 simplified (h=10).

Material datasheet: E-glass needle mat → · temperature class: by temperature →

FAQ

Questions on this topic

How much heat does a pipe at 300 °C lose with e-glass needle mat?
With 50 mm at 300 °C (λ=0.053 at mean): DN50 loses 89 W/m, DN100 137 W/m, DN200 227 W/m — vs 1,005 W/m bare for DN100. Full table on this page.
What surface temperature does e-glass needle mat give at 300 °C?
≈40 °C with 50 mm on DN100 (20 °C ambient, still air). Personnel-protection targets (≤45–60 °C) may need more thickness — see the 80/100 mm columns.