Home / Asia / Japan / Yokohama

Yokohama

Oil power plant in Kanagawa, Japan. Approximate location 35.4768, 139.679.

OilKanagawaJapanCCGT · HRSG

Yokohama is a 3,016 MW oil power station in Kanagawa, Japan. It is operated by Tokyo. Based on its capacity (estimated), it can supply roughly 2.3 million homes (estimated). It ranks #18 of 692 Japan power plants by installed capacity. Commissioned in 1964, it is around 62 years old — an older, legacy facility. In context, oil supplies about 2.5% of Japan's electricity; the national grid averages 477 gCO₂/kWh (32.7% low-carbon) (2025).

3,016Source-backed capacity
8HRSG unit(s)
2,264,585homes powered (est.)
1964commissioned (~62 yrs)

Plant data: WRI Global Power Plant Database (CC BY 4.0), id WRI1000626.

Data status

Known data

FacilityYokohama WRI
CountryJapan · Kanagawa WRI
Coordinates35.4768, 139.679 WRI
FuelOil WRI
MW installed capacity3,016 MW WRI source record; scope not independently normalised
OwnerTokyo WRI
Commissioned1964 WRI
TechnologyCCGT · HRSG WRI

Calculated from dataset

CO₂ emissions5,944,536 t CO₂/yr calculated
Capacity rank in country#18 of 692 calculated
Fuel-specific rank in country#5 of 41 calculated
Capacity vs country/fuel peers3.02× · 1,000 MW median · 41 peers calculated
Homes-powered equivalent2,264,585 calculated
Climate15.8°C · HDD 1,538 derived from coordinates
Environmental severityC4 · 40/100 derived from coordinates

Not available

GWh reported / yrNot available not in dataset

Known, modelled and calculated values are kept separate. Missing fields are shown as unavailable.

Data provenance

The capacity and/or fuel fields on this page include a source-backed provenance label from GEM, an official registry, Wikidata, OSM, or a cross-source match.

capacity: GEM tracker 2026 (location L100000405196); fuel: WRI source-record fuel

In context: how this plant compares

At 3,016 MW, Yokohama is well above the median oil plant in Japan (1,000 MW). Technically it is described as CCGT; combined-cycle with a heat-recovery steam generator (HRSG). Oil-fired plants burn heavy fuel oil or diesel, usually as peaking or backup capacity on islands and grids without gas pipelines; high fuel cost keeps their utilisation low.

Capacity comparison computed from the WRI Global Power Plant Database; fuel-type context is general engineering background.

Capacity vs largest oil plants in Japan

Hirono: 4,400 MW4kHironoKashima: 4,400 MW4kKashimaChita: 3,966 MW4kChitaAnegasaki: 3,150 MW3kAnegasakiYokohama: 3,016 MW3kYokohamaYokosuka: 2,274 MW2kYokosukaKainan: 2,100 MW2kKainanAtsumi: 1,900 MW2kAtsumi

Installed capacity (MW), WRI Global Power Plant Database (CC BY 4.0).

Owner

Operated by Tokyo. All plants by this company →

Local climate & thermal context

This oil plant burns oil or diesel to drive turbines or reciprocating engines. It sits in a humid subtropical climate (Köppen Cfa) — Northern Hemisphere, latitude 35.5°N — which shapes how much energy it can produce and how its output varies through the year.

15.8°Cannual mean temp
1,538heating degree-days (base 18°C)
770cooling degree-days (base 18°C)
4 melevation

Monthly mean temperature

J: 6 °CJF: 6 °CFM: 9 °CMA: 14 °CAM: 18 °CMJ: 22 °CJJ: 25 °CJA: 27 °CAS: 23 °CSO: 18 °CON: 13 °CND: 8 °CD27 °C

Heating degree-days here run 37% below the median power plant in this dataset — a proxy for how much extra energy heated equipment must replace through its surfaces in winter.

Climate heat-demand index: 35/100 — this site sits in the mid third of the power plants we cover by heating degree-days.

Climate normals: WorldClim 2.1 (1970–2000 monthly normals, 10 arc-min, CC BY 4.0); zone: Köppen-Geiger world climate classification (Kottek et al. 2006, 0.5° grid). Degree-days & heat-demand index computed by PowerAtlas — a modelled heat-demand proxy, not a measured site figure.

Site climate & environmental severity

For a plant’s outdoor hardware — heat-recovery steam generators (HRSG), expansion joints, valves, flanges and their insulation — the local climate sets how fast unprotected steel and coatings degrade. This site sits in a corrosive environment (estimated ISO 9223 class C4 — High), with humidity / wetness the leading environmental stress.

C4ISO 9223 corrosivity (indicative)
40/100environmental-severity index
20.8°Cseasonal temperature swing
53 kmdistance to coast

Higher environmental severity is exactly where protective removable insulation pays back most: a sheltered micro-climate slows corrosion, UV and thermal-cycling damage and extends outdoor hardware service life. This is an indicative site-climate context — not a condition assessment of any specific plant or operator.

Indicative estimate via the ISO 9223:2012 informative method (atmospheric corrosivity from temperature, time-of-wetness and airborne salinity), using WorldClim climate normals, the Köppen-Geiger class and coast distance. Indicative, not a measured corrosion rate.

How it compares & nearby plants

The #5 largest oil power plant of 41 in Japan by capacity.

Japan has 41 oil power plants in this dataset, together about 48,987 MW of capacity.

Nearby power plants

Location

Coordinates 35.4768, 139.679 from WRI Global Power Plant Database (CC BY 4.0). View on OpenStreetMap.

Frequently asked questions

What type of power plant is Yokohama?

Yokohama is a 3,016 MW source-record oil power plant in Kanagawa, Japan, commissioned in 1964.

How many homes can Yokohama power?

Its output is enough to supply roughly 2,264,585 homes (estimated).

Who operates Yokohama?

Yokohama is operated by Tokyo.

Built from open public data; no personal information. Operate this site? Request a correction or removal.