Oil power plant in Catalonia, Spain. Approximate location 42.702, 0.7956.

OilCataloniaSpain

VETEJAR is a 13 MW oil power plant in Catalonia, Spain. It is operated by VAPOR Y ELECTRICIDAD EL TEJAR S.L.. Based on its capacity (estimated), it can supply roughly 9.7k homes (estimated). It ranks #710 of 899 Spain power plants by installed capacity. Commissioned in 2010, it is around 16 years old — relatively modern. In context, oil supplies about 3.5% of Spain's electricity; the national grid averages 154 gCO₂/kWh (74.6% low-carbon) (2025).

13Legacy source-record capacity
9,686homes powered (est.)
2010commissioned (~16 yrs)

Plant data: WRI Global Power Plant Database (CC BY 4.0), id WRI1008027.

Data status

Known data

FacilityVETEJAR WRI
CountrySpain · Catalonia WRI
Coordinates42.702, 0.7956 WRI
FuelOil WRI
MW installed capacity13 MW WRI source record; scope not independently normalised
OwnerVAPOR Y ELECTRICIDAD EL TEJAR S.L. WRI
Commissioned2010 WRI

Calculated from dataset

CO₂ emissions25,426 t CO₂/yr calculated
Capacity rank in country#710 of 899 calculated
Fuel-specific rank in country#31 of 33 calculated
Capacity vs country/fuel peers0.19× · 67 MW median · 33 peers calculated
Homes-powered equivalent9,686 calculated
Climate2.5°C · HDD 5,651 derived from coordinates
Environmental severityC3 · 28/100 derived from coordinates

Not available

TechnologyNot available not in dataset
GWh reported / yrNot available not in dataset

Known, modelled and calculated values are kept separate. Missing fields are shown as unavailable.

Data provenance

The capacity and fuel fields on this page are source-record values from the upstream open dataset. They are useful for identification and ranking, but they have not been upgraded to a 2026 registry/GEM-location verified value.

capacity: WRI Global Power Plant Database source-record (legacy); fuel: WRI source-record fuel

In context: how this plant compares

At 13 MW, VETEJAR is below the median oil plant in Spain (67 MW). Oil-fired plants burn heavy fuel oil or diesel, usually as peaking or backup capacity on islands and grids without gas pipelines; high fuel cost keeps their utilisation low.

Capacity comparison computed from the WRI Global Power Plant Database; fuel-type context is general engineering background.

Capacity vs largest oil plants in Spain

CT SANTURCE 2: 897 MW897CT SANTURC…Granadilla power station: 749 MW749Granadilla…BARRANCO DE TIRAJANA 7 VAPOR 3 (CC1): 697 MW697BARRANCO D…GRANADILLA 1 GAS 1: 693 MW693GRANADILLA…SON REUS 3 TURBINA DE GAS N 3: 564 MW564SON REUS 3…CT ESCOMBRERAS 5: 537 MW537CT ESCOMBR…JINAMAR 10 GAS 2: 234 MW234JINAMAR 10…MAHON 10 BURMEISTER N 2: 195 MW195MAHON 10 …

Installed capacity (MW), WRI Global Power Plant Database (CC BY 4.0).

Owner

Operated by VAPOR Y ELECTRICIDAD EL TEJAR S.L..

Local climate & thermal context

This oil plant burns oil or diesel to drive turbines or reciprocating engines. It sits in a temperate oceanic climate (Köppen Cfb) — Northern Hemisphere, latitude 42.7°N — which shapes how much energy it can produce and how its output varies through the year.

2.5°Cannual mean temp
5,651heating degree-days (base 18°C)
0cooling degree-days (base 18°C)
2,250 melevation

Monthly mean temperature

J: -6 °CJF: -5 °CFM: -3 °CMA: -1 °CAM: 4 °CMJ: 8 °CJJ: 12 °CJA: 12 °CAS: 9 °CSO: 4 °CON: -1 °CND: -4 °CD12 °C

Heating degree-days here run 130% above the median power plant in this dataset — a proxy for how much extra energy heated equipment must replace through its surfaces in winter.

Climate heat-demand index: 97/100 — this site sits in the top third of the power plants we cover by heating degree-days.

Climate normals: WorldClim 2.1 (1970–2000 monthly normals, 10 arc-min, CC BY 4.0); zone: Köppen-Geiger world climate classification (Kottek et al. 2006, 0.5° grid). Degree-days & heat-demand index computed by PowerAtlas — a modelled heat-demand proxy, not a measured site figure.

Site climate & environmental severity

For a plant’s outdoor hardware — heat-recovery steam generators (HRSG), expansion joints, valves, flanges and their insulation — the local climate sets how fast unprotected steel and coatings degrade. This site sits in a moderately corrosive environment (estimated ISO 9223 class C3 — Medium), with humidity / wetness the leading environmental stress.

C3ISO 9223 corrosivity (indicative)
28/100environmental-severity index
18.0°Cseasonal temperature swing
144 kmdistance to coast

Higher environmental severity is exactly where protective removable insulation pays back most: a sheltered micro-climate slows corrosion, UV and thermal-cycling damage and extends outdoor hardware service life. This is an indicative site-climate context — not a condition assessment of any specific plant or operator.

Indicative estimate via the ISO 9223:2012 informative method (atmospheric corrosivity from temperature, time-of-wetness and airborne salinity), using WorldClim climate normals, the Köppen-Geiger class and coast distance. Indicative, not a measured corrosion rate.

How it compares & nearby plants

The #31 largest oil power plant of 33 in Spain by capacity.

Spain has 33 oil power plants in this dataset, together about 6,078 MW of capacity.

Nearby power plants

Location

Coordinates 42.702, 0.7956 from WRI Global Power Plant Database (CC BY 4.0). View on OpenStreetMap.

Frequently asked questions

What type of power plant is VETEJAR?

VETEJAR is a 13 MW source-record oil power plant in Catalonia, Spain, commissioned in 2010.

How many homes can VETEJAR power?

Its output is enough to supply roughly 9,686 homes (estimated).

Who operates VETEJAR?

VETEJAR is operated by VAPOR Y ELECTRICIDAD EL TEJAR S.L..