Home / South America / Argentina / SANTO TOME

SANTO TOME

Oil power plant in Corrientes, Argentina. Approximate location -28.5497, -56.0722.

OilCorrientesArgentina

SANTO TOME is a 3 MW oil power plant in Corrientes, Argentina. It is operated by DPEC. Based on its capacity (estimated), it can supply roughly 2.0k homes (estimated). It ranks #250 of 275 Argentina power plants by installed capacity. In context, oil supplies about 3.9% of Argentina's electricity; the national grid averages 346 gCO₂/kWh (41.6% low-carbon) (2025).

3Legacy source-record capacity
2,027homes powered (est.)

Plant data: WRI Global Power Plant Database (CC BY 4.0), id ARG0000135.

Data status

Known data

FacilitySANTO TOME WRI
CountryArgentina · Corrientes WRI
Coordinates-28.5497, -56.0722 WRI
FuelOil WRI
MW installed capacity3 MW WRI source record; scope not independently normalised
OwnerDPEC WRI

Calculated from dataset

CO₂ emissions5,322 t CO₂/yr calculated
Capacity rank in country#250 of 275 calculated
Fuel-specific rank in country#78 of 96 calculated
Capacity vs country/fuel peers0.24× · 11 MW median · 96 peers calculated
Homes-powered equivalent2,027 calculated
Climate20.7°C · HDD 240 derived from coordinates
Environmental severityC3 · 34/100 derived from coordinates

Not available

CommissionedNot available not in dataset
TechnologyNot available not in dataset
GWh reported / yrNot available not in dataset

Known, modelled and calculated values are kept separate. Missing fields are shown as unavailable.

Data provenance

The capacity and fuel fields on this page are source-record values from the upstream open dataset. They are useful for identification and ranking, but they have not been upgraded to a 2026 registry/GEM-location verified value.

capacity: WRI Global Power Plant Database source-record (legacy); fuel: WRI source-record fuel

In context: how this plant compares

At 3 MW, SANTO TOME is below the median oil plant in Argentina (11 MW). Oil-fired plants burn heavy fuel oil or diesel, usually as peaking or backup capacity on islands and grids without gas pipelines; high fuel cost keeps their utilisation low.

Capacity comparison computed from the WRI Global Power Plant Database; fuel-type context is general engineering background.

Capacity vs largest oil plants in Argentina

LA RIOJA: 42 MW42LA RIOJACT LA PLATA: 40 MW40CT LA PLATACT MEDANITOS (RINCON DE LOS SAUCES): 32 MW32CT MEDANIT…C.T. RUFINO: 32 MW32C.T. RUFINOBANDERA: 31 MW31BANDERACENTRAL TERMICA PIQUIRENDA SA: 30 MW30CENTRAL TE…CT FORMOSA II: 30 MW30CT FORMOSA…C.T. SAN VICENTE: 28 MW28C.T. SAN V…

Installed capacity (MW), WRI Global Power Plant Database (CC BY 4.0).

Owner

Operated by DPEC. All plants by this company →

Local climate & thermal context

This oil plant burns oil or diesel to drive turbines or reciprocating engines. It sits in a humid subtropical climate (Köppen Cfa) — Southern Hemisphere, latitude 28.5°S — which shapes how much energy it can produce and how its output varies through the year.

20.7°Cannual mean temp
240heating degree-days (base 18°C)
1,207cooling degree-days (base 18°C)
73 melevation

Monthly mean temperature

J: 26 °CJF: 26 °CFM: 24 °CMA: 21 °CAM: 18 °CMJ: 16 °CJJ: 15 °CJA: 16 °CAS: 18 °CSO: 20 °CON: 23 °CND: 26 °CD26 °C

Heating degree-days here run 90% below the median power plant in this dataset — a proxy for how much extra energy heated equipment must replace through its surfaces in winter.

Climate heat-demand index: 17/100 — this site sits in the bottom third of the power plants we cover by heating degree-days.

Climate normals: WorldClim 2.1 (1970–2000 monthly normals, 10 arc-min, CC BY 4.0); zone: Köppen-Geiger world climate classification (Kottek et al. 2006, 0.5° grid). Degree-days & heat-demand index computed by PowerAtlas — a modelled heat-demand proxy, not a measured site figure.

Site climate & environmental severity

For a plant’s outdoor hardware — heat-recovery steam generators (HRSG), expansion joints, valves, flanges and their insulation — the local climate sets how fast unprotected steel and coatings degrade. This site sits in a moderately corrosive environment (estimated ISO 9223 class C3 — Medium), with humidity / wetness the leading environmental stress.

C3ISO 9223 corrosivity (indicative)
34/100environmental-severity index
11.5°Cseasonal temperature swing
551 kmdistance to coast

Higher environmental severity is exactly where protective removable insulation pays back most: a sheltered micro-climate slows corrosion, UV and thermal-cycling damage and extends outdoor hardware service life. This is an indicative site-climate context — not a condition assessment of any specific plant or operator.

Indicative estimate via the ISO 9223:2012 informative method (atmospheric corrosivity from temperature, time-of-wetness and airborne salinity), using WorldClim climate normals, the Köppen-Geiger class and coast distance. Indicative, not a measured corrosion rate.

How it compares & nearby plants

The #78 largest oil power plant of 96 in Argentina by capacity.

Argentina has 96 oil power plants in this dataset, together about 1,199 MW of capacity.

Nearby power plants

Location

Coordinates -28.5497, -56.0722 from WRI Global Power Plant Database (CC BY 4.0). View on OpenStreetMap.

Frequently asked questions

What type of power plant is SANTO TOME?

SANTO TOME is a 3 MW source-record oil power plant in Corrientes, Argentina.

How many homes can SANTO TOME power?

Its output is enough to supply roughly 2,027 homes (estimated).

Who operates SANTO TOME?

SANTO TOME is operated by DPEC.

Built from open public data; no personal information. Operate this site? Request a correction or removal.