Coal power plant in Uttar Pradesh, India. Approximate location 27.818, 79.936.

CoalUttar PradeshIndiasubcritical

ROSA TPP PH - 1 is a 1,200 MW coal power station in Uttar Pradesh, India. It is operated by Reliance Power Ltd [100%]. Based on reported annual generation of 3,961 GWh, it can supply roughly 1.1 million homes. It ranks #333 of 2,229 India power plants by installed capacity. Commissioned in 2010, it is around 16 years old — relatively modern. In context, coal supplies about 70.8% of India's electricity; the national grid averages 670 gCO₂/kWh (26.7% low-carbon) (2025).

1,200Source-backed capacity
3,961GWh reported / yr
1,131,600homes powered
2010commissioned (~16 yrs)

Plant data: WRI Global Power Plant Database (CC BY 4.0), id IND0000381.

Data status

Known data

FacilityROSA TPP PH - 1 WRI
CountryIndia · Uttar Pradesh WRI
Coordinates27.818, 79.936 WRI
FuelCoal WRI
MW installed capacity1,200 MW WRI source record; scope not independently normalised
OwnerReliance Power Ltd [100%] WRI
Commissioned2010 WRI
Technologysubcritical WRI
GWh reported / yr3,961 GWh/yr WRI

Calculated from dataset

CO₂ emissions3,960,600 t CO₂/yr calculated
Capacity rank in country#333 of 2229 calculated
Fuel-specific rank in country#312 of 716 calculated
Capacity vs country/fuel peers1.20× · 1,000 MW median · 716 peers calculated
Homes-powered equivalent1,131,600 calculated from reported generation
Climate25.0°C · HDD 150 derived from coordinates
Environmental severityC3 · 39/100 derived from coordinates

Not available

GWh reported / yrNot available not in dataset

Known, modelled and calculated values are kept separate. Missing fields are shown as unavailable.

Data provenance

The capacity and/or fuel fields on this page include a source-backed provenance label from GEM, an official registry, Wikidata, OSM, or a cross-source match.

capacity: GEM tracker 2026 (location L100000102650); fuel: WRI source-record fuel

In context: how this plant compares

At 1,200 MW, ROSA TPP PH - 1 is well above the median coal plant in India (1,000 MW). Technically it is described as subcritical. Coal plants burn pulverised coal to raise high-pressure steam for a turbine; they run as baseload but are the most carbon-intensive mainstream source and the first targeted for retirement or efficiency retrofits.

Capacity comparison computed from the WRI Global Power Plant Database; fuel-type context is general engineering background.

Reported generation trend

2014: 7,847 GWh20142015: 6,434 GWh20152016: 7,270 GWh20162017: 7,091 GWh20172018: 3,961 GWh20188k GWh

Annual generation (GWh), WRI Global Power Plant Database (CC BY 4.0).

Owner

Operated by Reliance Power Ltd [100%].

Local climate & thermal context

This coal plant burns coal to raise high-pressure steam that spins a turbine-generator. It sits in a humid subtropical (dry winter) climate (Köppen Cwa) — Northern Hemisphere, latitude 27.8°N — which shapes how much energy it can produce and how its output varies through the year.

25.0°Cannual mean temp
150heating degree-days (base 18°C)
2,718cooling degree-days (base 18°C)
150 melevation

Monthly mean temperature

J: 15 °CJF: 18 °CFM: 23 °CMA: 29 °CAM: 33 °CMJ: 32 °CJJ: 30 °CJA: 29 °CAS: 28 °CSO: 26 °CON: 20 °CND: 16 °CD33 °C

Heating degree-days here run 94% below the median power plant in this dataset — a proxy for how much extra energy heated equipment must replace through its surfaces in winter.

Climate heat-demand index: 16/100 — this site sits in the bottom third of the power plants we cover by heating degree-days.

Climate normals: WorldClim 2.1 (1970–2000 monthly normals, 10 arc-min, CC BY 4.0); zone: Köppen-Geiger world climate classification (Kottek et al. 2006, 0.5° grid). Degree-days & heat-demand index computed by PowerAtlas — a modelled heat-demand proxy, not a measured site figure.

Site climate & environmental severity

For a plant’s outdoor hardware — heat-recovery steam generators (HRSG), expansion joints, valves, flanges and their insulation — the local climate sets how fast unprotected steel and coatings degrade. This site sits in a moderately corrosive environment (estimated ISO 9223 class C3 — Medium), with humidity / wetness the leading environmental stress.

C3ISO 9223 corrosivity (indicative)
39/100environmental-severity index
17.6°Cseasonal temperature swing
1045 kmdistance to coast

Higher environmental severity is exactly where protective removable insulation pays back most: a sheltered micro-climate slows corrosion, UV and thermal-cycling damage and extends outdoor hardware service life. This is an indicative site-climate context — not a condition assessment of any specific plant or operator.

Indicative estimate via the ISO 9223:2012 informative method (atmospheric corrosivity from temperature, time-of-wetness and airborne salinity), using WorldClim climate normals, the Köppen-Geiger class and coast distance. Indicative, not a measured corrosion rate.

How it compares & nearby plants

The #312 largest coal power plant of 716 in India by capacity.

India has 716 coal power plants in this dataset, together about 806,969 MW of capacity.

Nearby power plants

Location

Coordinates 27.818, 79.936 from WRI Global Power Plant Database (CC BY 4.0). View on OpenStreetMap.

Frequently asked questions

What type of power plant is ROSA TPP PH - 1?

ROSA TPP PH - 1 is a 1,200 MW source-record coal power plant in Uttar Pradesh, India, commissioned in 2010.

How much electricity does ROSA TPP PH - 1 generate?

ROSA TPP PH - 1 generates about 3,961 GWh of electricity per year.

How many homes can ROSA TPP PH - 1 power?

Its output is enough to supply roughly 1,131,600 homes.

Who operates ROSA TPP PH - 1?

ROSA TPP PH - 1 is operated by Reliance Power Ltd [100%].

Built from open public data; no personal information. Operate this site? Request a correction or removal.