Home / Oceania / Australia / Reece

Reece

Hydro power plant in Tasmania, Australia. Approximate location -41.7238, 145.1359.

HydroTasmaniaAustraliaconventional storage

Reece is a 244 MW hydro power station in Tasmania, Australia. It is operated by Hydro-Electric Corporation (Tasmania). Based on reported annual generation of 1,056 GWh, it can supply roughly 302k homes. It ranks #84 of 536 Australia power plants by installed capacity. Commissioned in 1986, it is around 40 years old — long-established. As a non-combustion source, it has no direct CO₂ emissions from generation. In context, hydro supplies about 4.3% of Australia's electricity; the national grid averages 525 gCO₂/kWh (38.6% low-carbon) (2025).

244Source-backed capacity
1,056GWh reported / yr
301,657homes powered
1986commissioned (~40 yrs)

Plant data: WRI Global Power Plant Database (CC BY 4.0), id AUS0000141.

Data status

Known data

FacilityReece WRI
CountryAustralia · Tasmania WRI
Coordinates-41.7238, 145.1359 WRI
FuelHydro WRI
MW installed capacity244 MW WRI source record; scope not independently normalised
OwnerHydro-Electric Corporation (Tasmania) WRI
Commissioned1986 WRI
Technologyconventional storage WRI
GWh reported / yr1,056 GWh/yr WRI

Calculated from dataset

Capacity rank in country#84 of 536 calculated
Fuel-specific rank in country#9 of 73 calculated
Capacity vs country/fuel peers5.42× · 45 MW median · 73 peers calculated
Homes-powered equivalent301,657 calculated from reported generation
Climate10.9°C · HDD 2,594 derived from coordinates
Environmental severityC4 · 31/100 derived from coordinates

Not available

GWh reported / yrNot available not in dataset
CO₂ emissionsnot applicable not applicable

Known, modelled and calculated values are kept separate. Missing fields are shown as unavailable.

Data provenance

The capacity and/or fuel fields on this page include a source-backed provenance label from GEM, an official registry, Wikidata, OSM, or a cross-source match.

capacity: GEM tracker 2026 operating-unit sum (location L100000600079); fuel: WRI source-record fuel

In context: how this plant compares

At 244 MW, Reece is well above the median hydro plant in Australia (45 MW). Technically it is described as conventional storage. Hydropower converts the energy of falling or flowing water into electricity; output depends on rainfall and reservoir level, and large dams also provide grid balancing and storage.

Capacity comparison computed from the WRI Global Power Plant Database; fuel-type context is general engineering background.

Reported generation trend

2013: 825 GWh20132014: 1,135 GWh20142015: 915 GWh20152016: 760 GWh20162017: 1,031 GWh20172018: 1,056 GWh20181k GWh

Annual generation (GWh), WRI Global Power Plant Database (CC BY 4.0).

Owner

Operated by Hydro-Electric Corporation (Tasmania). All plants by this company →

Local climate & thermal context

This hydro plant converts the energy of falling or flowing water through hydro turbines. It sits in a temperate oceanic climate (Köppen Cfb) — Southern Hemisphere, latitude 41.7°S — which shapes how much energy it can produce and how its output varies through the year.

10.9°Cannual mean temp
2,594heating degree-days (base 18°C)
0cooling degree-days (base 18°C)
266 melevation

Monthly mean temperature

J: 15 °CJF: 15 °CFM: 14 °CMA: 12 °CAM: 10 °CMJ: 8 °CJJ: 7 °CJA: 8 °CAS: 8 °CSO: 10 °CON: 12 °CND: 13 °CD15 °C

Heating degree-days here run 6% above the median power plant in this dataset — a proxy for how much extra energy heated equipment must replace through its surfaces in winter.

Climate heat-demand index: 52/100 — this site sits in the mid third of the power plants we cover by heating degree-days.

Climate normals: WorldClim 2.1 (1970–2000 monthly normals, 10 arc-min, CC BY 4.0); zone: Köppen-Geiger world climate classification (Kottek et al. 2006, 0.5° grid). Degree-days & heat-demand index computed by PowerAtlas — a modelled heat-demand proxy, not a measured site figure.

Site climate & environmental severity

For a plant’s outdoor hardware — heat-recovery steam generators (HRSG), expansion joints, valves, flanges and their insulation — the local climate sets how fast unprotected steel and coatings degrade. This site sits in a corrosive environment (estimated ISO 9223 class C4 — High), with humidity / wetness the leading environmental stress.

C4ISO 9223 corrosivity (indicative)
31/100environmental-severity index
8.1°Cseasonal temperature swing
32 kmdistance to coast

Higher environmental severity is exactly where protective removable insulation pays back most: a sheltered micro-climate slows corrosion, UV and thermal-cycling damage and extends outdoor hardware service life. This is an indicative site-climate context — not a condition assessment of any specific plant or operator.

Indicative estimate via the ISO 9223:2012 informative method (atmospheric corrosivity from temperature, time-of-wetness and airborne salinity), using WorldClim climate normals, the Köppen-Geiger class and coast distance. Indicative, not a measured corrosion rate.

How it compares & nearby plants

The #9 largest hydro power plant of 73 in Australia by capacity.

Australia has 73 hydro power plants in this dataset, together about 8,878 MW of capacity.

Nearby power plants

Location

Coordinates -41.7238, 145.1359 from WRI Global Power Plant Database (CC BY 4.0). View on OpenStreetMap.

Frequently asked questions

What type of power plant is Reece?

Reece is a 244 MW source-record hydro power plant in Tasmania, Australia, commissioned in 1986.

How much electricity does Reece generate?

Reece generates about 1,056 GWh of electricity per year.

How many homes can Reece power?

Its output is enough to supply roughly 301,657 homes.

Who operates Reece?

Reece is operated by Hydro-Electric Corporation (Tasmania).

Built from open public data; no personal information. Operate this site? Request a correction or removal.