Home / North Macedonia / Oslomej power station

Oslomej power station

Coal power plant in North Macedonia, North Macedonia. Approximate location 41.582133, 21.000288.

CoalNorth MacedoniaNorth Macedoniasubcritical

Oslomej power station is a 254.5 MW coal power station in North Macedonia, North Macedonia. It is operated by Elektrani na Severna Makedonija AD [100%]. Based on its capacity (estimated), it can supply roughly 318k homes (estimated). It ranks #4 of 6 North Macedonia power plants by installed capacity. Commissioned in 1980, it is around 46 years old — long-established.

254.5MW installed capacity
318,488homes powered (est.)
1980commissioned (~46 yrs)

Plant data: WRI Global Power Plant Database (CC BY 4.0), id GEM_coa_oslomej_north.

Data status

Known data

FacilityOslomej power station GEM-coal
CountryNorth Macedonia · North Macedonia GEM-coal
Coordinates41.582133, 21.000288 GEM-coal
FuelCoal GEM-coal
MW installed capacity254.5 MW GEM · 2026 · L100000101867; part of a generating complex
OwnerElektrani na Severna Makedonija AD [100%] GEM-coal
Commissioned1980 GEM-coal
Technologysubcritical GEM-coal

Calculated from dataset

CO₂ emissions1,114,710 t CO₂·a⁻¹ calculated
Capacity rank in country#4 / 6 calculated
Fuel-specific rank in country#2 / 2 calculated
Homes-powered equivalent318,488 calculated
Climate8.7°C · HDD 3,392 derived from coordinates
Environmental severityC3 · 32/100 derived from coordinates

Not available

GWh reported / yrNot available not in dataset

Known, modelled and calculated values are kept separate. Missing fields are shown as unavailable.

Capacity provenance

The public capacity above is the current source-record value. A 2026 tracker candidate lists 125 MW for Oslomej power station, but it is not used as the public primary value until scope is verified (unit vs operating vs installed/project total).

Data provenance

The capacity and/or fuel fields on this page include a source-backed provenance label from GEM, an official registry, Wikidata, OSM, or a cross-source match.

capacity: GEM · 2026 · L100000101867; fuel: GEM GCPT

In context: how this plant compares

Technically it is described as subcritical. Coal plants burn pulverised coal to raise high-pressure steam for a turbine; they run as baseload but are the most carbon-intensive mainstream source and the first targeted for retirement or efficiency retrofits.

Capacity comparison computed from the WRI Global Power Plant Database; fuel-type context is general engineering background.

Capacity vs largest coal plants in North Macedonia

Mariovo power station: 300 MW300Mariovo po…Oslomej power station: 254 MW254Oslomej po…

Installed capacity (MW), WRI Global Power Plant Database (CC BY 4.0).

Owner

Operated by Elektrani na Severna Makedonija AD [100%].

Local climate & thermal context

This coal plant burns coal to raise high-pressure steam that spins a turbine-generator. It sits in a temperate oceanic climate (Köppen Cfb) — Northern Hemisphere, latitude 41.6°N — which shapes how much energy it can produce and how its output varies through the year.

8.7°Cannual mean temp
3,392heating degree-days (base 18°C)
10cooling degree-days (base 18°C)
1,037 melevation

Monthly mean temperature

J: -1 °CJF: 0 °CFM: 4 °CMA: 8 °CAM: 13 °CMJ: 16 °CJJ: 18 °CJA: 18 °CAS: 14 °CSO: 10 °CON: 4 °CND: 1 °CD18 °C

Heating degree-days here run 38% above the median power plant in this dataset — a proxy for how much extra energy heated equipment must replace through its surfaces in winter.

Climate heat-demand index: 73/100 — this site sits in the top third of the power plants we cover by heating degree-days.

Climate normals: WorldClim 2.1 (1970–2000 monthly normals, 10 arc-min, CC BY 4.0); zone: Köppen-Geiger world climate classification (Kottek et al. 2006, 0.5° grid). Degree-days & heat-demand index computed by PowerAtlas — a modelled heat-demand proxy, not a measured site figure.

Site climate & environmental severity

For a plant’s outdoor hardware — heat-recovery steam generators (HRSG), expansion joints, valves, flanges and their insulation — the local climate sets how fast unprotected steel and coatings degrade. This site sits in a moderately corrosive environment (estimated ISO 9223 class C3 — Medium), with humidity / wetness the leading environmental stress.

C3ISO 9223 corrosivity (indicative)
32/100environmental-severity index
19.6°Cseasonal temperature swing
146 kmdistance to coast

Higher environmental severity is exactly where protective removable insulation pays back most: a sheltered micro-climate slows corrosion, UV and thermal-cycling damage and extends outdoor hardware service life. This is an indicative site-climate context — not a condition assessment of any specific plant or operator.

Indicative estimate via the ISO 9223:2012 informative method (atmospheric corrosivity from temperature, time-of-wetness and airborne salinity), using WorldClim climate normals, the Köppen-Geiger class and coast distance. Indicative, not a measured corrosion rate.

How it compares & nearby plants

The #2 largest coal power plant of 2 in North Macedonia by capacity.

North Macedonia has 2 coal power plants in this dataset, together about 554 MW of capacity.

Nearby power plants

Location

Coordinates 41.582133, 21.000288 from WRI Global Power Plant Database (CC BY 4.0). View on OpenStreetMap.

Frequently asked questions

What type of power plant is Oslomej power station?

Oslomej power station is a 254.5 MW coal power plant in North Macedonia, North Macedonia, commissioned in 1980.

How many homes can Oslomej power station power?

Its output is enough to supply roughly 318,488 homes (estimated).

Who operates Oslomej power station?

Oslomej power station is operated by Elektrani na Severna Makedonija AD [100%].

Built from open public data; no personal information. Operate this site? Request a correction or removal.