Home / South America / Uruguay / MOTORES CENTRAL BATLLE

MOTORES CENTRAL BATLLE

Oil power plant in Montevideo, Uruguay. Approximate location -34.8861, -56.1977.

OilMontevideoUruguayEngine

MOTORES CENTRAL BATLLE is a 80 MW oil power plant in Montevideo, Uruguay. It is operated by Administracion Nacional De Usinas y Trasmisiones Eléctricas [100%]. Based on its capacity (estimated), it can supply roughly 60k homes (estimated). It ranks #10 of 73 Uruguay power plants by installed capacity. Commissioned in 2010, it is around 16 years old — relatively modern. In context, oil supplies about 2.2% of Uruguay's electricity; the national grid averages 80 gCO₂/kWh (97.8% low-carbon) (2025).

80Legacy source-record capacity
60,068homes powered (est.)
2010commissioned (~16 yrs)

Plant data: WRI Global Power Plant Database (CC BY 4.0), id URY0000820.

Data status

Known data

FacilityMOTORES CENTRAL BATLLE WRI
CountryUruguay · Montevideo WRI
Coordinates-34.8861, -56.1977 WRI
FuelOil WRI
MW installed capacity80 MW WRI source record; scope not independently normalised
OwnerAdministracion Nacional De Usinas y Trasmisiones Eléctricas [100%] WRI
Commissioned2010 WRI
TechnologyEngine WRI

Calculated from dataset

CO₂ emissions157,680 t CO₂/yr calculated
Capacity rank in country#10 of 73 calculated
Fuel-specific rank in country#2 of 4 calculated
Homes-powered equivalent60,068 calculated
Climate16.3°C · HDD 1,050 derived from coordinates
Environmental severityC5 · 45/100 derived from coordinates

Not available

GWh reported / yrNot available not in dataset

Known, modelled and calculated values are kept separate. Missing fields are shown as unavailable.

Data provenance

The capacity and fuel fields on this page are source-record values from the upstream open dataset. They are useful for identification and ranking, but they have not been upgraded to a 2026 registry/GEM-location verified value.

capacity: WRI Global Power Plant Database source-record (legacy); fuel: WRI source-record fuel

In context: how this plant compares

Technically it is described as Engine. Oil-fired plants burn heavy fuel oil or diesel, usually as peaking or backup capacity on islands and grids without gas pipelines; high fuel cost keeps their utilisation low.

Capacity comparison computed from the WRI Global Power Plant Database; fuel-type context is general engineering background.

Capacity vs largest oil plants in Uruguay

PUNTA DEL TIGRE A: 300 MW300PUNTA DEL …MOTORES CENTRAL BATLLE: 80 MW80MOTORES CE…TURBINA RÍO BRANCO: 4 MW4TURBINA RÍ…SAN GREGORIO: 1 MW1SAN GREGOR…

Installed capacity (MW), WRI Global Power Plant Database (CC BY 4.0).

Owner

Operated by Administracion Nacional De Usinas y Trasmisiones Eléctricas [100%].

Local climate & thermal context

This oil plant burns oil or diesel to drive turbines or reciprocating engines. It sits in a humid subtropical climate (Köppen Cfa) — Southern Hemisphere, latitude 34.9°S — which shapes how much energy it can produce and how its output varies through the year.

16.3°Cannual mean temp
1,050heating degree-days (base 18°C)
433cooling degree-days (base 18°C)
26 melevation

Monthly mean temperature

J: 23 °CJF: 22 °CFM: 20 °CMA: 17 °CAM: 14 °CMJ: 11 °CJJ: 10 °CJA: 11 °CAS: 13 °CSO: 16 °CON: 18 °CND: 21 °CD23 °C

Heating degree-days here run 57% below the median power plant in this dataset — a proxy for how much extra energy heated equipment must replace through its surfaces in winter.

Climate heat-demand index: 27/100 — this site sits in the bottom third of the power plants we cover by heating degree-days.

Climate normals: WorldClim 2.1 (1970–2000 monthly normals, 10 arc-min, CC BY 4.0); zone: Köppen-Geiger world climate classification (Kottek et al. 2006, 0.5° grid). Degree-days & heat-demand index computed by PowerAtlas — a modelled heat-demand proxy, not a measured site figure.

Site climate & environmental severity

For a plant’s outdoor hardware — heat-recovery steam generators (HRSG), expansion joints, valves, flanges and their insulation — the local climate sets how fast unprotected steel and coatings degrade. This site sits in an aggressive, high-corrosion environment (estimated ISO 9223 class C5 — Very high), with marine salt corrosion the leading environmental stress.

C5ISO 9223 corrosivity (indicative)
45/100environmental-severity index
12.3°Cseasonal temperature swing
8 kmdistance to coast

Higher environmental severity is exactly where protective removable insulation pays back most: a sheltered micro-climate slows corrosion, UV and thermal-cycling damage and extends outdoor hardware service life. This is an indicative site-climate context — not a condition assessment of any specific plant or operator.

Indicative estimate via the ISO 9223:2012 informative method (atmospheric corrosivity from temperature, time-of-wetness and airborne salinity), using WorldClim climate normals, the Köppen-Geiger class and coast distance. Indicative, not a measured corrosion rate.

How it compares & nearby plants

The #2 largest oil power plant of 4 in Uruguay by capacity.

Uruguay has 4 oil power plants in this dataset, together about 386 MW of capacity.

Nearby power plants

Location

Coordinates -34.8861, -56.1977 from WRI Global Power Plant Database (CC BY 4.0). View on OpenStreetMap.

Frequently asked questions

What type of power plant is MOTORES CENTRAL BATLLE?

MOTORES CENTRAL BATLLE is a 80 MW source-record oil power plant in Montevideo, Uruguay, commissioned in 2010.

How many homes can MOTORES CENTRAL BATLLE power?

Its output is enough to supply roughly 60,068 homes (estimated).

Who operates MOTORES CENTRAL BATLLE?

MOTORES CENTRAL BATLLE is operated by Administracion Nacional De Usinas y Trasmisiones Eléctricas [100%].

Built from open public data; no personal information. Operate this site? Request a correction or removal.