Home / South America / Brazil / Monte Belo

Monte Belo

Hydro power plant in Rondonia, Brazil. Approximate location -11.9319, -62.1828.

HydroRondoniaBrazilOperação

Monte Belo is a 5 MW hydro power plant in Rondonia, Brazil. Based on its capacity (estimated), it can supply roughly 4.8k homes (estimated). It ranks #1626 of 2,572 Brazil power plants by installed capacity. Commissioned in 2001, it is around 25 years old — relatively modern. As a non-combustion source, it has no direct CO₂ emissions from generation. In context, hydro supplies about 51.8% of Brazil's electricity; the national grid averages 110 gCO₂/kWh (88.7% low-carbon) (2025).

5Source-backed capacity
4,805homes powered (est.)
2001commissioned (~25 yrs)

Plant data: WRI Global Power Plant Database (CC BY 4.0), id BRA0027072.

Data status

Known data

FacilityMonte Belo WRI
CountryBrazil · Rondonia WRI
Coordinates-11.9319, -62.1828 WRI
FuelHydro WRI
MW installed capacity5 MW WRI source record; scope not independently normalised
Commissioned2001 WRI

Official enrichment

Official registry IDPCH.PH.RO.027072-5.1 official source
Official statusOperação official source
Operation date2001-06-01 official source
MunicipalityAlta Floresta d´Oeste - RO official source

Calculated from dataset

Capacity rank in country#1626 of 2572 calculated
Fuel-specific rank in country#453 of 701 calculated
Capacity vs country/fuel peers0.42× · 12 MW median · 701 peers calculated
Homes-powered equivalent4,805 calculated
Climate23.9°C · HDD 0 derived from coordinates
Environmental severityC3 · 32/100 derived from coordinates

Not available

OwnerNot available not in dataset
TechnologyNot available not in dataset
GWh reported / yrNot available not in dataset
CO₂ emissionsnot applicable not applicable

Known, modelled and calculated values are kept separate. Missing fields are shown as unavailable.

Data provenance

The capacity and/or fuel fields on this page include a source-backed provenance label from GEM, an official registry, Wikidata, OSM, or a cross-source match.

capacity: ANEEL SIGA official registry; fuel: WRI source-record fuel

In context: how this plant compares

At 5 MW, Monte Belo is below the median hydro plant in Brazil (12 MW). Its current lifecycle status is “Operação” — so it is not yet, or no longer, generating at full output. Hydropower converts the energy of falling or flowing water into electricity; output depends on rainfall and reservoir level, and large dams also provide grid balancing and storage.

Capacity comparison computed from the WRI Global Power Plant Database; fuel-type context is general engineering background.

Capacity vs largest hydro plants in Brazil

Belo Monte: 11,233 MW11kBelo MonteTucuruí: 8,535 MW9kTucuruíItaipu (Parte Brasileira): 7,000 MW7kItaipu (Pa…Jirau: 3,750 MW4kJirauSanto Antônio: 3,568 MW4kSanto Antô…Ilha Solteira: 3,444 MW3kIlha Solte…Xingó: 3,162 MW3kXingóPaulo Afonso IV: 2,462 MW2kPaulo Afon…

Installed capacity (MW), WRI Global Power Plant Database (CC BY 4.0).

Local climate & thermal context

This hydro plant converts the energy of falling or flowing water through hydro turbines. It sits in a tropical savanna climate (Köppen Aw) — Southern Hemisphere, latitude 11.9°S — which shapes how much energy it can produce and how its output varies through the year.

23.9°Cannual mean temp
0heating degree-days (base 18°C)
2,151cooling degree-days (base 18°C)
434 melevation

Monthly mean temperature

J: 24 °CJF: 24 °CFM: 24 °CMA: 24 °CAM: 23 °CMJ: 22 °CJJ: 23 °CJA: 24 °CAS: 24 °CSO: 25 °CON: 24 °CND: 24 °CD25 °C

This site has effectively no heating season (tropical/equatorial climate), so winter heat loss is not the driver here. The thermal concern shifts to year-round process heat and humidity/heat-driven corrosion of hot equipment.

Climate normals: WorldClim 2.1 (1970–2000 monthly normals, 10 arc-min, CC BY 4.0); zone: Köppen-Geiger world climate classification (Kottek et al. 2006, 0.5° grid). Degree-days & heat-demand index computed by PowerAtlas — a modelled heat-demand proxy, not a measured site figure.

Site climate & environmental severity

For a plant’s outdoor hardware — heat-recovery steam generators (HRSG), expansion joints, valves, flanges and their insulation — the local climate sets how fast unprotected steel and coatings degrade. This site sits in a moderately corrosive environment (estimated ISO 9223 class C3 — Medium), with humidity / wetness the leading environmental stress.

C3ISO 9223 corrosivity (indicative)
32/100environmental-severity index
2.1°Cseasonal temperature swing
1161 kmdistance to coast

Higher environmental severity is exactly where protective removable insulation pays back most: a sheltered micro-climate slows corrosion, UV and thermal-cycling damage and extends outdoor hardware service life. This is an indicative site-climate context — not a condition assessment of any specific plant or operator.

Indicative estimate via the ISO 9223:2012 informative method (atmospheric corrosivity from temperature, time-of-wetness and airborne salinity), using WorldClim climate normals, the Köppen-Geiger class and coast distance. Indicative, not a measured corrosion rate.

How it compares & nearby plants

The #453 largest hydro power plant of 701 in Brazil by capacity.

Brazil has 701 hydro power plants in this dataset, together about 105,987 MW of capacity.

Nearby power plants

Location

Coordinates -11.9319, -62.1828 from WRI Global Power Plant Database (CC BY 4.0). View on OpenStreetMap.

Frequently asked questions

What type of power plant is Monte Belo?

Monte Belo is a 5 MW source-record hydro power plant in Rondonia, Brazil, commissioned in 2001.

How many homes can Monte Belo power?

Its output is enough to supply roughly 4,805 homes (estimated).

Built from open public data; no personal information. Operate this site? Request a correction or removal.