Home / North America / Canada / Miller Creek

Miller Creek — Canada

Hydro power plant in British Columbia, Canada. Approximate location 50.3499, -122.8714.

HydroBritish ColumbiaCanadarun-of-river

Miller Creek is a 33 MW hydro power plant in British Columbia, Canada. It is operated by Innergex Inc. Based on its capacity (estimated), it can supply roughly 33k homes (estimated). It ranks #475 of 1,210 Canada power plants by installed capacity. Commissioned in 2003, it is around 23 years old — relatively modern. As a non-combustion source, it has no direct CO₂ emissions from generation. In context, hydro supplies about 52.8% of Canada's electricity; the national grid averages 191 gCO₂/kWh (77.0% low-carbon) (2025).

33MW installed capacity
33,037homes powered (est.)
2003commissioned (~23 yrs)

Plant data: WRI Global Power Plant Database (CC BY 4.0), id CAN0008128.

Data status

Known data

FacilityMiller Creek WRI
CountryCanada · British Columbia WRI
Coordinates50.3499, -122.8714 WRI
FuelHydro WRI
MW installed capacity33 MW GEM · 2026 · L100001054598; operating plant capacity
Verification noteQuality label backfilled from existing source-backed capacity provenance on 2026-07-05; capacity value was not changed. source-verified
OwnerInnergex Inc WRI
Commissioned2003 WRI
Technologyrun-of-river WRI

Calculated from dataset

Capacity rank in country#475 / 1210 calculated
Fuel-specific rank in country#188 / 556 calculated
Capacity vs country/fuel peers2.75× · 12 MW · n=556 calculated
Homes-powered equivalent33,037 calculated
Climate2.5°C · HDD 5,635 derived from coordinates
Environmental severityC2 · 23/100 derived from coordinates

Not available

GWh reported / yrNot available not in dataset
CO₂ emissionsnot applicable not applicable

Known, modelled and calculated values are kept separate. Missing fields are shown as unavailable.

Data provenance

Source of the capacity and fuel values:

capacity: GEM · 2026 · L100001054598; fuel: WRI GPPD

In context: how this plant compares

At 33 MW, Miller Creek is well above the median hydro plant in Canada (12 MW). Technically it is described as run-of-river. Hydropower converts the energy of falling or flowing water into electricity; output depends on rainfall and reservoir level, and large dams also provide grid balancing and storage.

Capacity comparison computed from the WRI Global Power Plant Database; fuel-type context is general engineering background.

Key facts

Share of Canada hydro capacity
less than 0.1% of 81,037 MW across 556 plants in this dataset
Age among peers
154 of 189 dated hydro plants in Canada are older

Calculated from the capacity and generation records in this dataset (WRI Global Power Plant Database (CC BY 4.0)).

Capacity vs largest hydro plants in Canada

Robert-Bourassa: 5,616 MW6kRobert-Bou…Churchill Falls: 5,428 MW5kChurchill …La Grande-4: 2,779 MW3kLa Grande-4Mica: 2,746 MW3kMicaG.M. Shrum: 2,730 MW3kG.M. ShrumRevelstoke: 2,480 MW2kRevelstokeLa Grande-3: 2,417 MW2kLa Grande-3La Grande-2-A: 2,106 MW2kLa Grande-…

Installed capacity (MW), WRI Global Power Plant Database (CC BY 4.0).

Local climate & thermal context

This hydro plant converts the energy of falling or flowing water through hydro turbines. It sits in a subarctic (boreal) climate (Köppen Dfc) — Northern Hemisphere, latitude 50.3°N — which shapes how much energy it can produce and how its output varies through the year.

2.5°Cannual mean temp
5,635heating degree-days (base 18°C)
0cooling degree-days (base 18°C)
1,356 melevation

Monthly mean temperature

J: -6 °CJF: -4 °CFM: -2 °CMA: 1 °CAM: 5 °CMJ: 9 °CJJ: 12 °CJA: 13 °CAS: 9 °CSO: 4 °CON: -3 °CND: -6 °CD13 °C

Heating degree-days here run 129% above the median power plant in this dataset — a proxy for how much extra energy heated equipment must replace through its surfaces in winter.

Climate heat-demand index: 97/100 — this site sits in the top third of the power plants we cover by heating degree-days.

Climate normals: WorldClim 2.1 (1970–2000 monthly normals, 10 arc-min, CC BY 4.0); zone: Köppen-Geiger world climate classification (Kottek et al. 2006, 0.5° grid). Degree-days & heat-demand index computed by PowerAtlas — a modelled heat-demand proxy, not a measured site figure.

Site climate & environmental severity

This site sits in a mild atmospheric environment (estimated ISO 9223 class C2 — Low), with humidity / wetness the leading environmental stress.

C2ISO 9223 corrosivity (indicative)
23/100environmental-severity index
19.0°Cseasonal temperature swing
270 kmdistance to coast

Indicative estimate via the ISO 9223:2012 informative method (atmospheric corrosivity from temperature, time-of-wetness and airborne salinity), using WorldClim climate normals, the Köppen-Geiger class and coast distance. Indicative, not a measured corrosion rate.

How it compares & nearby plants

The #188 largest hydro power plant of 556 in Canada by capacity.

Canada has 556 hydro power plants in this dataset, together about 81,037 MW of capacity.

Nearby power plants

Location

Coordinates 50.3499, -122.8714 from WRI Global Power Plant Database (CC BY 4.0). View on OpenStreetMap.

Frequently asked questions

What type of power plant is Miller Creek?

Miller Creek is a 33 MW hydro power plant in British Columbia, Canada, commissioned in 2003.

Who operates Miller Creek?

Miller Creek is operated by Innergex Inc.

Built from open public data; no personal information. Operate this site? Request a correction or removal.