Home / Asia / India / Manesar Captive power plant

Manesar Captive power plant

Gas power plant in Haryana, India. Approximate location 28.3669, 76.8952.

GasHaryanaIndiaCCGT · HRSGCO₂ modelled

Manesar Captive power plant is a 118 MW gas power station in Haryana, India. It is operated by Maruti Suzuki India Ltd. Based on its capacity (estimated), it can supply roughly 132k homes (estimated). It ranks #820 of 2,229 India power plants by installed capacity. Its modelled annual emissions are 126,364 t CO₂/yr (Climate TRACE), equivalent to about 29k cars driven for a year. In context, gas supplies about 2.3% of India's electricity; the national grid averages 670 gCO₂/kWh (26.7% low-carbon) (2025).

118Legacy source-record capacity
1HRSG unit(s)
132,338homes powered (est.)
126,364t CO₂ / yr (Climate TRACE)

Plant data: WRI Global Power Plant Database (CC BY 4.0), id CT-4946.

Data status

Known data

FacilityManesar Captive power plant Climate TRACE
CountryIndia · Haryana Climate TRACE
Coordinates28.3669, 76.8952 Climate TRACE
FuelGas Climate TRACE
MW installed capacity118 MW Climate TRACE source record; scope not independently normalised
OwnerMaruti Suzuki India Ltd Climate TRACE
TechnologyCCGT · HRSG Climate TRACE

Modelled source data

CO₂ emissions126,364 t CO₂/yr modelled · Climate TRACE

Calculated from dataset

Capacity rank in country#820 of 2229 calculated
Fuel-specific rank in country#85 of 118 calculated
Capacity vs country/fuel peers0.49× · 238 MW median · 118 peers calculated
Homes-powered equivalent132,338 calculated
Climate24.8°C · HDD 282 derived from coordinates
Environmental severityC1 · 46/100 derived from coordinates

Not available

CommissionedNot available not in dataset
GWh reported / yrNot available not in dataset

Known, modelled and calculated values are kept separate. Missing fields are shown as unavailable.

Capacity provenance

The public capacity above is the current source-record value. A 2026 tracker candidate lists 78 MW for Manesar Captive power plant, but it is not used as the public primary value until scope is verified (unit vs operating vs installed/project total).

Capacity claim grade: A3_MAJOR_REVIEW_SCOPE_STATUS - recommended action: manual_scope_status_check - confidence: low_until_scope_verified. This follows a claim-based data model: value + scope + source + confidence, rather than silently overwriting records.

Data provenance

The capacity and fuel fields on this page are source-record values from the upstream open dataset. They are useful for identification and ranking, but they have not been upgraded to a 2026 registry/GEM-location verified value.

capacity: Climate TRACE source-record capacity (modelled/legacy); fuel: Climate TRACE source-record fuel

In context: how this plant compares

At 118 MW, Manesar Captive power plant is below the median gas plant in India (238 MW). Technically it is described as CCGT; combined-cycle with a heat-recovery steam generator (HRSG). Gas plants burn natural gas either in open-cycle turbines for fast peaking, or in combined-cycle units that recover exhaust heat in an HRSG to reach roughly 55–62% efficiency — the cleanest-burning fossil option.

Capacity comparison computed from the WRI Global Power Plant Database; fuel-type context is general engineering background.

~126,364 t CO₂/yr (modelled) — in everyday terms

This facility's annual emissions are roughly equivalent to:

29kpassenger cars driven for a year
16khomes' yearly energy use
2.1 milliontree seedlings grown 10 years to absorb it

Equivalencies via US EPA Greenhouse Gas Equivalencies; modelled emissions from Climate TRACE.

Capacity vs largest gas plants in India

Godhra power station: 2,000 MW2kGodhra pow…RATNAGIRI GAS: 1,968 MW2kRATNAGIRI …Sugen Combined Cycle power plant: 1,532 MW2kSugen Comb…Pragati Combined Cycle Gas Turbine-III power station: 1,500 MW2kPragati Co…KONDAPALLI GT: 1,476 MW1kKONDAPALLI…PRAGATI CCCP -III: 1,371 MW1kPRAGATI CC…DGEN MEGA CCCP: 1,200 MW1kDGEN MEGA …DGEN Mega Combined Cycle power plant: 1,200 MW1kDGEN Mega …

Installed capacity (MW), WRI Global Power Plant Database (CC BY 4.0).

Owner

Operated by Maruti Suzuki India Ltd.

Local climate & thermal context

This gas plant burns natural gas in a turbine — often in a combined-cycle setup — to generate electricity. It sits in a hot semi-arid steppe climate (Köppen BSh) — Northern Hemisphere, latitude 28.4°N — which shapes how much energy it can produce and how its output varies through the year.

24.8°Cannual mean temp
282heating degree-days (base 18°C)
2,771cooling degree-days (base 18°C)
265 melevation

Monthly mean temperature

J: 13 °CJF: 16 °CFM: 22 °CMA: 29 °CAM: 33 °CMJ: 34 °CJJ: 31 °CJA: 29 °CAS: 29 °CSO: 26 °CON: 20 °CND: 15 °CD34 °C

Heating degree-days here run 89% below the median power plant in this dataset — a proxy for how much extra energy heated equipment must replace through its surfaces in winter.

Climate heat-demand index: 18/100 — this site sits in the bottom third of the power plants we cover by heating degree-days.

A gas turbine here also runs ~7% below its ISO (15°C) rating at this annual mean (typical CCGT curve, estimate).

Climate normals: WorldClim 2.1 (1970–2000 monthly normals, 10 arc-min, CC BY 4.0); zone: Köppen-Geiger world climate classification (Kottek et al. 2006, 0.5° grid). Degree-days & heat-demand index computed by PowerAtlas — a modelled heat-demand proxy, not a measured site figure.

Site climate & environmental severity

For a plant’s outdoor hardware — heat-recovery steam generators (HRSG), expansion joints, valves, flanges and their insulation — the local climate sets how fast unprotected steel and coatings degrade. This site sits in a benign, low-corrosion environment (estimated ISO 9223 class C1 — Very low), with dust abrasion the leading environmental stress.

C1ISO 9223 corrosivity (indicative)
46/100environmental-severity index
20.3°Cseasonal temperature swing
947 kmdistance to coast

Higher environmental severity is exactly where protective removable insulation pays back most: a sheltered micro-climate slows corrosion, UV and thermal-cycling damage and extends outdoor hardware service life. This is an indicative site-climate context — not a condition assessment of any specific plant or operator.

Indicative estimate via the ISO 9223:2012 informative method (atmospheric corrosivity from temperature, time-of-wetness and airborne salinity), using WorldClim climate normals, the Köppen-Geiger class and coast distance. Indicative, not a measured corrosion rate.

How it compares & nearby plants

The #85 largest gas power plant of 118 in India by capacity.

India has 118 gas power plants in this dataset, together about 44,242 MW of capacity.

Nearby power plants

Location

Coordinates 28.3669, 76.8952 from WRI Global Power Plant Database (CC BY 4.0). View on OpenStreetMap.

Frequently asked questions

What type of power plant is Manesar Captive power plant?

Manesar Captive power plant is a 118 MW source-record gas power plant in Haryana, India.

How many homes can Manesar Captive power plant power?

Its output is enough to supply roughly 132,338 homes (estimated).

Who operates Manesar Captive power plant?

Manesar Captive power plant is operated by Maruti Suzuki India Ltd.

How much CO₂ does Manesar Captive power plant emit?

Manesar Captive power plant has modelled emissions of about 126,364 tonnes of CO₂ per year (Climate TRACE).

Built from open public data; no personal information. Operate this site? Request a correction or removal.