Landis

Gas power plant in Saskatchewan, Canada. Approximate location 52.1988, -108.4509.

GasSaskatchewanCanadaOCGT

Landis is a 78 MW gas power plant in Saskatchewan, Canada. It is operated by Ontario Power Generation. Based on its capacity (estimated), it can supply roughly 88k homes (estimated). It ranks #331 of 1,211 Canada power plants by installed capacity. Commissioned in 1975, it is around 51 years old — an older, legacy facility. In context, gas supplies about 17.8% of Canada's electricity; the national grid averages 191 gCO₂/kWh (77.0% low-carbon) (2025).

78Source-backed capacity
87,850homes powered (est.)
1975commissioned (~51 yrs)

Plant data: WRI Global Power Plant Database (CC BY 4.0), id CAN1060487.

Data status

Known data

FacilityLandis WRI
CountryCanada · Saskatchewan WRI
Coordinates52.1988, -108.4509 WRI
FuelGas WRI
MW installed capacity78 MW WRI source record; scope not independently normalised
OwnerOntario Power Generation WRI
Commissioned1975 WRI
TechnologyOCGT WRI

Calculated from dataset

CO₂ emissions122,990 t CO₂/yr calculated
Capacity rank in country#331 of 1211 calculated
Fuel-specific rank in country#101 of 112 calculated
Capacity vs country/fuel peers0.46× · 170 MW median · 112 peers calculated
Homes-powered equivalent87,850 calculated
Climate2.3°C · HDD 5,715 derived from coordinates
Environmental severityC2 · 32/100 derived from coordinates

Not available

GWh reported / yrNot available not in dataset

Known, modelled and calculated values are kept separate. Missing fields are shown as unavailable.

Data provenance

The capacity and/or fuel fields on this page include a source-backed provenance label from GEM, an official registry, Wikidata, OSM, or a cross-source match.

capacity: GEM tracker 2026 (location L100000405232); fuel: WRI source-record fuel

In context: how this plant compares

At 78 MW, Landis is below the median gas plant in Canada (170 MW). Technically it is described as OCGT. Gas plants burn natural gas either in open-cycle turbines for fast peaking, or in combined-cycle units that recover exhaust heat in an HRSG to reach roughly 55–62% efficiency — the cleanest-burning fossil option.

Capacity comparison computed from the WRI Global Power Plant Database; fuel-type context is general engineering background.

Capacity vs largest gas plants in Canada

Alberta Sundance power station: 2,121 MW2kAlberta Su…Lennox: 2,100 MW2kLennoxGreenlight Electricity Centre: 1,864 MW2kGreenlight…Beacon AI Centers Indus Project: 1,504 MW2kBeacon AI …Genesee Data Centre Project power station: 1,500 MW2kGenesee Da…Wonder Valley power station: 1,200 MW1kWonder Val…Greenfield Energy Centre: 1,038 MW1kGreenfield…Burrard: 950 MW950Burrard

Installed capacity (MW), WRI Global Power Plant Database (CC BY 4.0).

Owner

Operated by Ontario Power Generation. All plants by this company →

Local climate & thermal context

This gas plant burns natural gas in a turbine — often in a combined-cycle setup — to generate electricity. It sits in a warm-summer humid continental climate (Köppen Dfb) — Northern Hemisphere, latitude 52.2°N — which shapes how much energy it can produce and how its output varies through the year.

2.3°Cannual mean temp
5,715heating degree-days (base 18°C)
0cooling degree-days (base 18°C)
659 melevation

Monthly mean temperature

J: -16 °CJF: -13 °CFM: -6 °CMA: 4 °CAM: 11 °CMJ: 16 °CJJ: 18 °CJA: 17 °CAS: 11 °CSO: 5 °CON: -6 °CND: -13 °CD18 °C

Heating degree-days here run 133% above the median power plant in this dataset — a proxy for how much extra energy heated equipment must replace through its surfaces in winter.

Climate heat-demand index: 97/100 — this site sits in the top third of the power plants we cover by heating degree-days.

A gas turbine here also runs ~0% below its ISO (15°C) rating at this annual mean (typical CCGT curve, estimate).

Climate normals: WorldClim 2.1 (1970–2000 monthly normals, 10 arc-min, CC BY 4.0); zone: Köppen-Geiger world climate classification (Kottek et al. 2006, 0.5° grid). Degree-days & heat-demand index computed by PowerAtlas — a modelled heat-demand proxy, not a measured site figure.

Site climate & environmental severity

For a plant’s outdoor hardware — heat-recovery steam generators (HRSG), expansion joints, valves, flanges and their insulation — the local climate sets how fast unprotected steel and coatings degrade. This site sits in a mild atmospheric environment (estimated ISO 9223 class C2 — Low), with thermal cycling the leading environmental stress.

C2ISO 9223 corrosivity (indicative)
32/100environmental-severity index
33.8°Cseasonal temperature swing
1025 kmdistance to coast

Higher environmental severity is exactly where protective removable insulation pays back most: a sheltered micro-climate slows corrosion, UV and thermal-cycling damage and extends outdoor hardware service life. This is an indicative site-climate context — not a condition assessment of any specific plant or operator.

Indicative estimate via the ISO 9223:2012 informative method (atmospheric corrosivity from temperature, time-of-wetness and airborne salinity), using WorldClim climate normals, the Köppen-Geiger class and coast distance. Indicative, not a measured corrosion rate.

How it compares & nearby plants

The #101 largest gas power plant of 112 in Canada by capacity.

Canada has 112 gas power plants in this dataset, together about 37,176 MW of capacity.

Nearby power plants

Location

Coordinates 52.1988, -108.4509 from WRI Global Power Plant Database (CC BY 4.0). View on OpenStreetMap.

Frequently asked questions

What type of power plant is Landis?

Landis is a 78 MW source-record gas power plant in Saskatchewan, Canada, commissioned in 1975.

How many homes can Landis power?

Its output is enough to supply roughly 87,850 homes (estimated).

Who operates Landis?

Landis is operated by Ontario Power Generation.

Built from open public data; no personal information. Operate this site? Request a correction or removal.