Home / North America / Honduras / La Grecia

La Grecia

Biomass power plant in Choluteca, Honduras. Approximate location 13.2432, -87.3529.

BiomassCholutecaHonduras

La Grecia is a 12 MW biomass power plant in Choluteca, Honduras. It is operated by Empresa Nacional De Energia Electrica. Based on its capacity (estimated), it can supply roughly 17k homes (estimated). It ranks #38 of 47 Honduras power plants by installed capacity. In context, biomass supplies about 6.7% of Honduras's electricity; the national grid averages 322 gCO₂/kWh (55.4% low-carbon) (2024).

12Legacy source-record capacity
16,518homes powered (est.)

Plant data: WRI Global Power Plant Database (CC BY 4.0), id WRI1029340.

Data status

Known data

FacilityLa Grecia WRI
CountryHonduras · Choluteca WRI
Coordinates13.2432, -87.3529 WRI
FuelBiomass WRI
MW installed capacity12 MW WRI source record; scope not independently normalised
OwnerEmpresa Nacional De Energia Electrica WRI

Calculated from dataset

Capacity rank in country#38 of 47 calculated
Fuel-specific rank in country#2 of 4 calculated
Homes-powered equivalent16,518 calculated
Climate28.5°C · HDD 0 derived from coordinates
Environmental severityC4 · 42/100 derived from coordinates

Not available

CommissionedNot available not in dataset
TechnologyNot available not in dataset
GWh reported / yrNot available not in dataset
CO₂ emissionsNot available not in dataset

Known, modelled and calculated values are kept separate. Missing fields are shown as unavailable.

Data provenance

The capacity and fuel fields on this page are source-record values from the upstream open dataset. They are useful for identification and ranking, but they have not been upgraded to a 2026 registry/GEM-location verified value.

capacity: WRI Global Power Plant Database source-record (legacy); fuel: WRI source-record fuel

In context: how this plant compares

Biomass plants burn organic material such as wood, residues or waste-derived fuel to raise steam; they are dispatchable and counted as low-carbon where the feedstock is sustainably sourced.

Capacity comparison computed from the WRI Global Power Plant Database; fuel-type context is general engineering background.

Capacity vs largest biomass plants in Honduras

Compania Azucarera Hondurena: 26 MW26Compania A…La Grecia: 12 MW12La GreciaTres Valles: 8 MW8Tres VallesAzulosa: 4 MW4Azulosa

Installed capacity (MW), WRI Global Power Plant Database (CC BY 4.0).

Owner

Operated by Empresa Nacional De Energia Electrica. All plants by this company →

Local climate & thermal context

This biomass plant burns organic material (wood, residues) to raise steam for a turbine. It sits in a tropical savanna climate (Köppen Aw) — Northern Hemisphere, latitude 13.2°N — which shapes how much energy it can produce and how its output varies through the year.

28.5°Cannual mean temp
0heating degree-days (base 18°C)
3,840cooling degree-days (base 18°C)
5 melevation

Monthly mean temperature

J: 28 °CJF: 29 °CFM: 29 °CMA: 30 °CAM: 30 °CMJ: 28 °CJJ: 29 °CJA: 29 °CAS: 28 °CSO: 28 °CON: 28 °CND: 28 °CD30 °C

This site has effectively no heating season (tropical/equatorial climate), so winter heat loss is not the driver here. The thermal concern shifts to year-round process heat and humidity/heat-driven corrosion of hot equipment.

Climate normals: WorldClim 2.1 (1970–2000 monthly normals, 10 arc-min, CC BY 4.0); zone: Köppen-Geiger world climate classification (Kottek et al. 2006, 0.5° grid). Degree-days & heat-demand index computed by PowerAtlas — a modelled heat-demand proxy, not a measured site figure.

Site climate & environmental severity

For a plant’s outdoor hardware — heat-recovery steam generators (HRSG), expansion joints, valves, flanges and their insulation — the local climate sets how fast unprotected steel and coatings degrade. This site sits in a corrosive environment (estimated ISO 9223 class C4 — High), with humidity / wetness the leading environmental stress.

C4ISO 9223 corrosivity (indicative)
42/100environmental-severity index
2.5°Cseasonal temperature swing
76 kmdistance to coast

Higher environmental severity is exactly where protective removable insulation pays back most: a sheltered micro-climate slows corrosion, UV and thermal-cycling damage and extends outdoor hardware service life. This is an indicative site-climate context — not a condition assessment of any specific plant or operator.

Indicative estimate via the ISO 9223:2012 informative method (atmospheric corrosivity from temperature, time-of-wetness and airborne salinity), using WorldClim climate normals, the Köppen-Geiger class and coast distance. Indicative, not a measured corrosion rate.

How it compares & nearby plants

The #2 largest biomass power plant of 4 in Honduras by capacity.

Honduras has 4 biomass power plants in this dataset, together about 50 MW of capacity.

Nearby power plants

Location

Coordinates 13.2432, -87.3529 from WRI Global Power Plant Database (CC BY 4.0). View on OpenStreetMap.

Frequently asked questions

What type of power plant is La Grecia?

La Grecia is a 12 MW source-record biomass power plant in Choluteca, Honduras.

How many homes can La Grecia power?

Its output is enough to supply roughly 16,518 homes (estimated).

Who operates La Grecia?

La Grecia is operated by Empresa Nacional De Energia Electrica.

Built from open public data; no personal information. Operate this site? Request a correction or removal.