Home / South America / Argentina / Ingeniero White thermal power plant

Ingeniero White thermal power plant — Argentina

Gas power plant in Buenos Aires, Argentina. Approximate location -38.784889, -62.252908.

GasBuenos AiresArgentinaEngine

Ingeniero White thermal power plant is a 99.6 MW gas power plant in Buenos Aires, Argentina. It is operated by Pampa Energia SA [100%]. Based on its capacity (estimated), it can supply roughly 112k homes (estimated). It ranks #92 of 275 Argentina power plants by installed capacity. Commissioned in 2017, it is around 9 years old — relatively modern. In context, gas supplies about 52.7% of Argentina's electricity; the national grid averages 346 gCO₂/kWh (41.6% low-carbon) (2025).

99.6MW installed capacity
112,178homes powered (est.)
2017commissioned (~9 yrs)

Plant data: WRI Global Power Plant Database (CC BY 4.0), id GOGPT_ingenierowhite_argent.

Data status

Known data

FacilityIngeniero White thermal power plant GEM-GOGPT
CountryArgentina · Buenos Aires GEM-GOGPT
Coordinates-38.784889, -62.252908 GEM-GOGPT
FuelGas GEM-GOGPT
MW installed capacity99.6 MW GEM · 2026 · L100000408505; operating plant capacity
Verification noteQuality label backfilled from existing source-backed capacity provenance on 2026-07-05; capacity value was not changed. source-verified
OwnerPampa Energia SA [100%] GEM-GOGPT
Commissioned2017 GEM-GOGPT
TechnologyEngine GEM-GOGPT

Calculated from dataset

CO₂ emissions157,049 t CO₂·a⁻¹ calculated
Capacity rank in country#92 / 275 calculated
Fuel-specific rank in country#59 / 95 calculated
Capacity vs country/fuel peers0.80× · 125 MW · n=95 calculated
Homes-powered equivalent112,178 calculated
Climate15.1°C · HDD 1,455 derived from coordinates
Environmental severityC4 · 35/100 derived from coordinates

Not available

GWh reported / yrNot available not in dataset

Known, modelled and calculated values are kept separate. Missing fields are shown as unavailable.

Data provenance

Source of the capacity and fuel values:

capacity: GEM · 2026 · L100000408505; fuel: GEM GOGPT

In context: how this plant compares

At 99.6 MW, Ingeniero White thermal power plant is below the median gas plant in Argentina (125 MW). Technically it is described as Engine. Gas plants burn natural gas either in open-cycle turbines for fast peaking, or in combined-cycle units that recover exhaust heat in an HRSG to reach roughly 55–62% efficiency — the cleanest-burning fossil option.

Capacity comparison computed from the WRI Global Power Plant Database; fuel-type context is general engineering background.

Key facts

Share of Argentina gas capacity
0.4% of 22,760 MW across 95 plants in this dataset
Age among peers
39 of 63 dated gas plants in Argentina are older

Calculated from the capacity and generation records in this dataset (WRI Global Power Plant Database (CC BY 4.0)).

Capacity vs largest gas plants in Argentina

NUEVO PUERTO: 1,218 MW1kNUEVO PUER…Guillermo Brown power station: 876 MW876Guillermo …AES Paraná power station: 870 MW870AES Paraná…CENTRAL TERMOELECTRICA MANUEL BELGRANO: 868 MW868CENTRAL TE…Manuel Belgrano I power station: 868 MW868Manuel Bel…CENTRAL TERMOELECTRICA TIMBUES: 865 MW865CENTRAL TE…DOCK SUD: 861 MW861DOCK SUDCT ENSENADA DE BARRAGAN: 848 MW848CT ENSENAD…

Installed capacity (MW), WRI Global Power Plant Database (CC BY 4.0).

Owner

Operated by Pampa Energia SA [100%].

Local climate & thermal context

This gas plant burns natural gas in a turbine — often in a combined-cycle setup — to generate electricity. It sits in a humid subtropical climate (Köppen Cfa) — Southern Hemisphere, latitude 38.8°S — which shapes how much energy it can produce and how its output varies through the year.

15.1°Cannual mean temp
1,455heating degree-days (base 18°C)
376cooling degree-days (base 18°C)
2 melevation

Monthly mean temperature

J: 22 °CJF: 22 °CFM: 19 °CMA: 15 °CAM: 11 °CMJ: 8 °CJJ: 8 °CJA: 9 °CAS: 12 °CSO: 15 °CON: 18 °CND: 21 °CD22 °C

Heating degree-days here run 41% below the median power plant in this dataset — a proxy for how much extra energy heated equipment must replace through its surfaces in winter.

Climate heat-demand index: 33/100 — this site sits in the bottom third of the power plants we cover by heating degree-days.

A gas turbine here also runs ~0% below its ISO (15°C) rating at this annual mean (typical CCGT curve, estimate).

Climate normals: WorldClim 2.1 (1970–2000 monthly normals, 10 arc-min, CC BY 4.0); zone: Köppen-Geiger world climate classification (Kottek et al. 2006, 0.5° grid). Degree-days & heat-demand index computed by PowerAtlas — a modelled heat-demand proxy, not a measured site figure.

Site climate & environmental severity

This site sits in a corrosive environment (estimated ISO 9223 class C4 — High), with humidity / wetness the leading environmental stress.

C4ISO 9223 corrosivity (indicative)
35/100environmental-severity index
14.6°Cseasonal temperature swing
67 kmdistance to coast

Indicative estimate via the ISO 9223:2012 informative method (atmospheric corrosivity from temperature, time-of-wetness and airborne salinity), using WorldClim climate normals, the Köppen-Geiger class and coast distance. Indicative, not a measured corrosion rate.

How it compares & nearby plants

The #59 largest gas power plant of 95 in Argentina by capacity.

Argentina has 95 gas power plants in this dataset, together about 22,760 MW of capacity.

Nearby power plants

Location

Coordinates -38.784889, -62.252908 from WRI Global Power Plant Database (CC BY 4.0). View on OpenStreetMap.

Frequently asked questions

What type of power plant is Ingeniero White thermal power plant?

Ingeniero White thermal power plant is a 99.6 MW gas power plant in Buenos Aires, Argentina, commissioned in 2017.

Who operates Ingeniero White thermal power plant?

Ingeniero White thermal power plant is operated by Pampa Energia SA [100%].

Built from open public data; no personal information. Operate this site? Request a correction or removal.